| 09/08/2026 | R:RGH FRAME | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 9/4/2026 11:24:09 AM
9/4/2026 11:24 AM Savannah smith
Contact Name: Savannah smith
Site Address: 4372 KELLWOOD DR
Phone: 6106807347
e-Mail: savannahlee352@gmail.com
9/8/2026 12:33:01 PM
NOT APPROVED-
1) THREE LVL BEAM QTY & FLOOR JOIST HANGERS OK
2) CLARIFICATION ON LVL ASSEMBLY (CONNECTION NAILING) IF ADEQUATE TO SIMPSON STRONG TIE SDS25312 FASTENERS AS SHOWN ON
Plan.
DETAIL 4 - LVL ASSEMBLY DETAILS.
3) WOOD POST FROM BOTTOM OF THREE PLY LVL BEAM TO FOUNDATION T.O.W. DOESN'T MATCH STAMPED PLANS SHOWING A STEEL POST.
4) CLARIFICATION ON QTY & SQUASH BLOCKING BETWEEN FLOOR AND TOP OF STEEL BEAM/ IN BASEMENT/ CRAWLSPACE.
5) CORRECT AS BUILT CONDITIONS TO MATCH STAMPED SUBMITTED PLANS OR UPLOAD A STAMPED LETTER FROM A COLORADO DESIGN PROFESSIONAL AS BUILT CONDITIONS ARE OK.
REST OF RGH FRAME - OK.
|
|
| 09/21/2026 | R:RE_ROUGH FRAME | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 9/15/2026 2:51:32 PM
9/15/2026 2:51 PM Savannah smith
Contact Name: Savannah smith
Site Address: 4372 KELLWOOD DR
Phone: 6106807347
e-Mail: savannahlee352@gmail.com
9/21/2026 12:40:17 PM
No answer at the door and no answer at the phone number provided. Left door hanger please recall inspection when someone, 18 or older, will be home.
|
|
| 10/02/2026 | R:ROUGH FRAME | MARTIN MAGERS | CANCEL | eTRAKiT Inspection Request | 9/29/2026 4:30:26 PM
9/29/2026 4:30 PM Savannah smith
Contact Name: Savannah smith
Site Address: 4372 KELLWOOD DR
Phone: 6106807347
e-Mail: savannahlee352@gmail.com
9/30/2026 9:06:54 PM
9/30/2026 9:06 PM Savannah smith
Contact Name: Savannah smith
Site Address: 4372 KELLWOOD DR
Phone: 6106807347
e-Mail: savannahlee352@gmail.com
10/2/2026 11:30:19 AM
Canceled per text from homeowner.
|
|
| 10/05/2026 | R:ROUGH FRAME | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 10/3/2026 6:17:08 PM
10/3/2026 6:17 PM Savannah smith
Contact Name: Savannah smith
Site Address: 4372 KELLWOOD DR
Phone: 6106807347
e-Mail: savannahlee352@gmail.com
10/5/2026 11:10:06 AM
1. Missing fire blocking at top and bottom of both sides.
2. Finish moving electrical wires into walls.
New structural posts approved.
|
|