Permit No. 26-2756 Permit Type   RESIDENTIAL BASEMENT FINISH Site Address   5934 STILL MEADOW PL
CASTLE ROCK, CO 80104
Applied   07/28/2026 Applicant   THE RENOVATION SPECIALISTS BY KYLE
Approved   08/27/2026 Owner   LIANA LYNN BROOKS
Issued   08/28/2026 Contractor  
Parent Permit No.   Description   BASEMENT FINISH
  Notes   Value below is based on stated fee schedule of $20.51/sf
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 09/01/2026R:ROUGH FRAMESHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/31/2026 11:39:36 AM 8/31/2026 11:39 AM THE RENOVATION SPECIALISTS BY KYLE Contact Name: THE RENOVATION SPECIALISTS BY KYLE Site Address: 5934 STILL MEADOW PL Phone: 3529782952 e-Mail: CAMBRIACUSTOMBUILD@GMAIL.COM 9/1/2026 11:02:44 AM Rough frame inspection approved Schedule shower pan inspection when ready Electrical plumbing, mechanical approved Notes Aav vent to be accessible for bathroom at final above sink Under stairs floor protection required at final Bathroom Exhaust fan to be set at 50 cfm Verify main panel located in garage circuits feeding basement

 09/01/2026R:INSULATIONSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/31/2026 11:39:37 AM 8/31/2026 11:39 AM THE RENOVATION SPECIALISTS BY KYLE Contact Name: THE RENOVATION SPECIALISTS BY KYLE Site Address: 5934 STILL MEADOW PL Phone: 3529782952 e-Mail: CAMBRIACUSTOMBUILD@GMAIL.COM 9/1/2026 11:02:47 AM Insulation inspection approved

 09/01/2026R:GROUND PLUMBINGSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/31/2026 11:39:37 AM 8/31/2026 11:39 AM THE RENOVATION SPECIALISTS BY KYLE Contact Name: THE RENOVATION SPECIALISTS BY KYLE Site Address: 5934 STILL MEADOW PL Phone: 3529782952 e-Mail: CAMBRIACUSTOMBUILD@GMAIL.COM 9/1/2026 11:02:49 AM Ground plumbing inspection approved Underground Plumbing was existing installed by builder

 09/18/2026R:SHOWER PANCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request9/17/2026 12:03:28 PM 9/17/2026 12:03 PM THE RENOVATION SPECIALISTS BY KYLE Contact Name: THE RENOVATION SPECIALISTS BY KYLE Site Address: 5934 STILL MEADOW PL Phone: 3529782952 e-Mail: CAMBRIACUSTOMBUILD@GMAIL.COM 9/18/2026 1:45:54 PM Approved

 10/15/2026R:FINAL BUILDING BASEMENT**SHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request10/14/2026 1:50:36 PM 10/14/2026 1:50 PM THE RENOVATION SPECIALISTS BY KYLE Contact Name: THE RENOVATION SPECIALISTS BY KYLE Site Address: 5934 STILL MEADOW PL Phone: 3529782952 e-Mail: CAMBRIACUSTOMBUILD@GMAIL.COM 10/15/2026 10:20:10 AM Final building inspection not approved 1. Could not verify basement bathroom gfci receptacle breaker to rest it after gfci test 2. Could not verify receptacle on north east side of stairwell is arch fault gfci combo receptacle 3. Receptacle above bump out in basement living area loose 4. Update panel schedule in garage Recall final building inspection when corrections are completed Rest of final building approved Plumbing, mechanical, good

 10/20/2026R:RE FINAL BUILDING BASEMENT**SHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request10/19/2026 11:36:28 AM 10/19/2026 11:36 AM THE RENOVATION SPECIALISTS BY KYLE Contact Name: THE RENOVATION SPECIALISTS BY KYLE Site Address: 5934 STILL MEADOW PL Phone: 3529782952 e-Mail: CAMBRIACUSTOMBUILD@GMAIL.COM 10/20/2026 9:10:38 AM Final basement inspection approved All corrections completed Electrical, plumbing,mechanical good