Permit No. 26-2694 Permit Type   RESIDENTIAL BASEMENT FINISH Site Address   776 SHEEP SORREL PL
CASTLE ROCK, CO 80104
Applied   07/22/2026 Applicant   RTP CONSTRUCTION LLC
Approved   07/28/2026 Owner   WILLIAM AND KATHLEEN SCHWARTZ TRUST
Issued   07/29/2026 Contractor  
Parent Permit No.   26-2676 Description   BASEMENT FINISH
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 08/18/2026R:GROUND PLUMBINGJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request8/17/2026 10:07:34 AM 8/17/2026 10:07 AM RTP CONSTRUCTION LLC Rough plumbing only - including underground Contact Name: RTP CONSTRUCTION LLC Site Address: 776 SHEEP SORREL PL Phone: 3038825362 e-Mail: HANS@RTPCONSTUCTIONLLC.COM 8/18/2026 12:03:35 PM APPROVED. NOTE: MAKE SURE ALL PLUMBING CLEAN OUTS HAVE CODE COMPLIANT ACCESS PANELS.

 08/21/2026R:ROUGH ELECTRICALSHAWN VALENZUELAAPPROVEDFull rough inspection8/20/2026 12:42:50 PM 8/20/2026 12:42 PM RTP CONSTRUCTION LLC Ground plumbing inspection already completed. Contact Name: RTP CONSTRUCTION LLC Site Address: 776 SHEEP SORREL PL Phone: 3038825362 e-Mail: HANS@RTPCONSTUCTIONLLC.COM 8/21/2026 12:46:29 PM Rough electrical inspection approved Notes Electrical fire place ran with dedicated 12/3 romex upload specs of electrical fire place to permit. Will require before final inspection At time of inspection new furnace electrical is incomplete will verify at final Cold water bond to be accessible at final All basement receptacle required gfci protection arc fault protection All basement lights require arc fault protection

 08/21/2026R:SHOWER PANJOE CARBAUGHCANCELFull rough inspection8/20/2026 12:42:50 PM 8/20/2026 12:42 PM RTP CONSTRUCTION LLC Ground plumbing inspection already completed. Contact Name: RTP CONSTRUCTION LLC Site Address: 776 SHEEP SORREL PL Phone: 3038825362 e-Mail: HANS@RTPCONSTUCTIONLLC.COM 8/21/2026 3:07:39 PM CANCELED. NOTE: SHOWER PAN INSPECTION NOT REQUIRED FOR BATHTUB.

 08/21/2026R:ROUGH FRAMEJOE CARBAUGHNOT APPROVEDFull rough inspection8/20/2026 12:42:50 PM 8/20/2026 12:42 PM RTP CONSTRUCTION LLC Ground plumbing inspection already completed. Contact Name: RTP CONSTRUCTION LLC Site Address: 776 SHEEP SORREL PL Phone: 3038825362 e-Mail: HANS@RTPCONSTUCTIONLLC.COM 8/21/2026 3:07:41 PM NOT APPROVED- 1) INCORRECT MATERIAL FOR FIRE BLOCKING. 2) DAMAGED AIR DUCT DO TO CAN LIGHTING/ OUTSIDE OF GYM ROOM. REST OF RGH FRAME - OK. NOTE: 1) PLEASE UPDATE PLANS & UPLOAD FIREPLACE MANUFACTURED INSTALLATION INSTRUCTIONS BY FINAL. 2) CHECK DIRECT VENT CONNECTION AT NEW FURNACE AT FINAL.

 08/21/2026R:INSULATIONJOE CARBAUGHAPPROVEDFull rough inspection8/20/2026 12:42:51 PM 8/20/2026 12:42 PM RTP CONSTRUCTION LLC Ground plumbing inspection already completed. Contact Name: RTP CONSTRUCTION LLC Site Address: 776 SHEEP SORREL PL Phone: 3038825362 e-Mail: HANS@RTPCONSTUCTIONLLC.COM 8/21/2026 3:07:44 PM APPROVED- NOTE: ALL PRE-EXISTING BLANKET INSULATION OK AT EXTERIOR WALLS IN BASEMENT.

 08/24/2026R:RE ROUGH FRAMESHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request8/21/2026 2:26:41 PM 8/21/2026 2:26 PM RTP CONSTRUCTION LLC all passed except fireblocking, foundation wall insulation, and dented HVAC bath supply over hallway Contact Name: RTP CONSTRUCTION LLC Site Address: 776 SHEEP SORREL PL Phone: 3038825362 e-Mail: HANS@RTPCONSTUCTIONLLC.COM 8/24/2026 1:16:43 PM Rough frame inspection not approved 1. New gas line for furnace needs to be on test Rest of rough frame inspection approved ok to drywall as new gas line is incomplete unfinished mechanical room Recall rough fame inspection when gas line is on test.

 09/03/2026R:RE ROUGH FRAMEJOE CARBAUGHCANCELOnly need gas pipe leak test9/2/2026 7:14:44 AM 9/2/2026 7:14 AM RTP CONSTRUCTION LLC All reviewed and passed except gas pipe test Contact Name: RTP CONSTRUCTION LLC Site Address: 776 SHEEP SORREL PL Phone: 3038825362 e-Mail: HANS@RTPCONSTUCTIONLLC.COM 9/3/2026 8:03:14 AM not ready per rick

 09/09/2026R:RE ROUGH FRAMESHAWN VALENZUELAAPPROVEDGas leak test only9/8/2026 7:01:14 AM 9/8/2026 7:01 AM RTP CONSTRUCTION LLC All rough frame passed - all that''s needed is a leak test verification on the new gas pipe. Contact Name: RTP CONSTRUCTION LLC Site Address: 776 SHEEP SORREL PL Phone: 3038825362 e-Mail: HANS@RTPCONSTUCTIONLLC.COM 9/9/2026 11:28:17 AM Rough frame inspection approved Plumbing, mechanical electrical approved Schedule final building inspection when ready

 10/22/2026R:FINAL BUILDING BASEMENT**SHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request10/21/2026 10:53:02 AM 10/21/2026 10:53 AM RTP CONSTRUCTION LLC Contact Name: RTP CONSTRUCTION LLC Site Address: 776 SHEEP SORREL PL Phone: 3038825362 e-Mail: HANS@RTPCONSTUCTIONLLC.COM 10/22/2026 10:25:33 AM Final building basement inspection not approved 1. Receptacles in wet bar tile missing spark rings and receptacles loose 2. Missing switched outlet for disposal 3. Both receptacles that were added to exterior have no power 4. Mc going to fan under deck is not outdoor rated. Fan box installed is not outdoor-rated. Fan is rated for outdoor use 5. Ac requires gfci protection 210.8 2023 nec 6. Seal hole on exterior for new ac line set 7. Unable to test electrical fire place at time of inspection Plumbing approved recall inspections when all corrections are completed Note Outdoor ceiling fan underneath deck has been installed. It is not on plans. Two outdoor receptacles have been added that are not on plans both on back side of basement at grade level A humidifier has been added to new furnace, which does not show on plans

 11/17/2026R:RE FINAL BUILDING BASEMENT**SHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request11/12/2026 6:30:26 PM 11/12/2026 6:30 PM RTP CONSTRUCTION LLC Contact Name: RTP CONSTRUCTION LLC Site Address: 776 SHEEP SORREL PL Phone: 3038825362 e-Mail: HANS@RTPCONSTUCTIONLLC.COM 11/12/2026 9:28:51 PM 11/12/2026 9:28 PM RTP CONSTRUCTION LLC Contact Name: RTP CONSTRUCTION LLC Site Address: 776 SHEEP SORREL PL Phone: 3038825362 e-Mail: HANS@RTPCONSTUCTIONLLC.COM 11/17/2026 2:06:21 PM Final building inspection approved All corrections have been completed Electrical plumbing, mechanical approved