11/21/2026
10:57 PM
 
Permit No. 26-2501 Permit Type   RESIDENTIAL BASEMENT FINISH Site Address   4945 PERSIMMON LN
CASTLE ROCK, CO 80109
Applied   07/06/2026 Applicant   JKAL GROUP LLC
Approved   08/11/2026 Owner   MICHAEL EDWARD BRUNETTI & AMY E ALLEN
Issued   08/11/2026 Contractor  
Parent Permit No.   Description   BASEMENT FINISH
  Notes   Kitchenette, Bathroom, Bedroom
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 08/12/2026R:GROUND PLUMBINGMARTIN MAGERSCANCELeTRAKiT Inspection Request8/11/2026 10:21:51 AM 8/11/2026 10:21 AM JKAL GROUP LLC Contact Name: JKAL GROUP LLC Site Address: 4945 PERSIMMON LN Phone: 7202994733 e-Mail: JAY@JKALBUILD.COM 8/12/2026 8:01:49 AM not ready

 08/13/2026R:GROUND PLUMBINGVINCE RAPONEAPPROVEDeTRAKiT Inspection Request8/12/2026 3:35:51 PM 8/12/2026 3:35 PM JKAL GROUP LLC Morning would be great. Contact Name: JKAL GROUP LLC Site Address: 4945 PERSIMMON LN Phone: 7202994733 e-Mail: JAY@JKALBUILD.COM 8/13/2026 10:01:38 AM Underground plumbing okay Change permit type to ADU Revise and resubmit print showing 220 range Schedule rough frame when ready

 08/19/2026R:RE ROUGH FRAMEVINCE RAPONEAPPROVEDeTRAKiT Inspection Request8/18/2026 3:16:40 PM 8/18/2026 3:16 PM JKAL GROUP LLC Please walk to the right side of the house, through the fence, and down to the sliding glass door. No need to knock just come on in. Contact Name: JKAL GROUP LLC Site Address: 4945 PERSIMMON LN Phone: 7202994733 e-Mail: JAY@JKALBUILD.COM 8/19/2026 1:04:30 PM Rough frame approved Mechanical plumbing electrical

 09/15/2026R:SHOWER PANJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/14/2026 9:33:58 PM 9/14/2026 9:33 PM JKAL GROUP LLC Please go around the right side of house into the basement Contact Name: JKAL GROUP LLC Site Address: 4945 PERSIMMON LN Phone: 7202994733 e-Mail: JAY@JKALBUILD.COM 9/15/2026 7:27:47 AM 1) SHOWER HAS GREATER THAN 900SQ INCHES OF INTERIOR CROSS SECTIONAL AREA & NOT LESS THAN 30 INCHES IN MINIMUM DIMENSION PER CODE. 2) UNDER IRC SHOWER RECEPTORS FINISHED CURB THRESHOLD IS JUST ABOVE 2 INCH MINIMUM AND UNDER 9 INCH MAX. 3) SLOPE WAS CHECKED WITH THE DIGITAL LEVEL AND WAS FOUND TO BE NOT LESS THAN 1/4 UNIT VERTICAL AND 12 UNITS HORIZONTAL. 4) FLOOR DRAIN & FLANGED SIZE MEET CODE. 5) THE LINNER MATERIAL COMPLIES WITH ASTM D4068 or ASTM D4551 PER CODE. 9/15/2026 7:53:50 AM 1) SHOWER HAS GREATER THAN 900SQ INCHES OF INTERIOR CROSS SECTIONAL AREA & NOT LESS THAN 30 INCHES IN MINIMUM DIMENSION PER CODE. 2) UNDER IRC SHOWER RECEPTORS FINISHED CURB THRESHOLD IS JUST ABOVE 2 INCH MINIMUM AND UNDER 9 INCH MAX. 3) SLOPE WAS CHECKED WITH THE DIGITAL LEVEL AND WAS FOUND TO BE NOT LESS THAN 1/4 UNIT VERTICAL AND 12 UNITS HORIZONTAL. 4) FLOOR DRAIN & FLANGED SIZE MEET CODE. 5) THE LINNER MATERIAL COMPLIES WITH ASTM D4068 or ASTM PER CODE. 9/15/2026 10:09:33 AM APPROVED. NOTES: NOTES ARE ACCIDENTALLY DOUBLED.

 10/22/2026R:FINAL BUILDING BASEMENT**VINCE RAPONENOT APPROVEDeTRAKiT Inspection Request10/21/2026 12:59:34 PM 10/21/2026 12:59 PM BIANCO ELECTRIC LLC Contact Christian Kingsley at 720-333-6089 Contact Name: BIANCO ELECTRIC LLC Site Address: 4945 PERSIMMON LN Phone: 3038623811 e-Mail: JBIANCO@BIANCO-ELECTRIC.COM 10/22/2026 10:37:48 AM Plumbing incomplete Electrical- dryer and range need gfci protection Kitchen small appliance need arc fault protection Schedule final building when ready

 10/27/2026R:FINAL BUILDINGVINCE RAPONEAPPROVEDeTRAKiT Inspection Request10/26/2026 9:16:38 PM 10/26/2026 9:16 PM JKAL GROUP LLC Contact Name: JKAL GROUP LLC Site Address: 4945 PERSIMMON LN Phone: 7202994733 e-Mail: JAY@JKALBUILD.COM 10/27/2026 1:53:48 PM Final building approved