| 08/12/2026 | R:GROUND PLUMBING | MARTIN MAGERS | CANCEL | eTRAKiT Inspection Request | 8/11/2026 10:21:51 AM
8/11/2026 10:21 AM JKAL GROUP LLC
Contact Name: JKAL GROUP LLC
Site Address: 4945 PERSIMMON LN
Phone: 7202994733
e-Mail: JAY@JKALBUILD.COM
8/12/2026 8:01:49 AM
not ready
|
|
| 08/13/2026 | R:GROUND PLUMBING | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 8/12/2026 3:35:51 PM
8/12/2026 3:35 PM JKAL GROUP LLC
Morning would be great.
Contact Name: JKAL GROUP LLC
Site Address: 4945 PERSIMMON LN
Phone: 7202994733
e-Mail: JAY@JKALBUILD.COM
8/13/2026 10:01:38 AM
Underground plumbing okay
Change permit type to ADU
Revise and resubmit print showing 220 range
Schedule rough frame when ready
|
|
| 08/19/2026 | R:RE ROUGH FRAME | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 8/18/2026 3:16:40 PM
8/18/2026 3:16 PM JKAL GROUP LLC
Please walk to the right side of the house, through the fence, and down to the sliding glass door. No need to knock just come on in.
Contact Name: JKAL GROUP LLC
Site Address: 4945 PERSIMMON LN
Phone: 7202994733
e-Mail: JAY@JKALBUILD.COM
8/19/2026 1:04:30 PM
Rough frame approved
Mechanical plumbing electrical
|
|
| 09/15/2026 | R:SHOWER PAN | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 9/14/2026 9:33:58 PM
9/14/2026 9:33 PM JKAL GROUP LLC
Please go around the right side of house into the basement
Contact Name: JKAL GROUP LLC
Site Address: 4945 PERSIMMON LN
Phone: 7202994733
e-Mail: JAY@JKALBUILD.COM
9/15/2026 7:27:47 AM
1) SHOWER HAS GREATER THAN 900SQ INCHES OF INTERIOR CROSS SECTIONAL AREA & NOT LESS THAN 30 INCHES IN MINIMUM DIMENSION PER CODE.
2) UNDER IRC SHOWER RECEPTORS FINISHED CURB THRESHOLD IS JUST ABOVE 2 INCH MINIMUM AND UNDER 9 INCH MAX.
3) SLOPE WAS CHECKED WITH THE DIGITAL LEVEL AND WAS FOUND TO BE NOT LESS THAN 1/4 UNIT VERTICAL AND 12 UNITS HORIZONTAL.
4) FLOOR DRAIN & FLANGED SIZE MEET CODE.
5) THE LINNER MATERIAL COMPLIES WITH ASTM D4068 or ASTM D4551 PER CODE.
9/15/2026 7:53:50 AM
1) SHOWER HAS GREATER THAN 900SQ INCHES OF INTERIOR CROSS SECTIONAL AREA & NOT LESS THAN 30 INCHES IN MINIMUM DIMENSION PER CODE.
2) UNDER IRC SHOWER RECEPTORS FINISHED CURB THRESHOLD IS JUST ABOVE 2 INCH MINIMUM AND UNDER 9 INCH MAX.
3) SLOPE WAS CHECKED WITH THE DIGITAL LEVEL AND WAS FOUND TO BE NOT LESS THAN 1/4 UNIT VERTICAL AND 12 UNITS HORIZONTAL.
4) FLOOR DRAIN & FLANGED SIZE MEET CODE.
5) THE LINNER MATERIAL COMPLIES WITH ASTM D4068 or ASTM PER CODE.
9/15/2026 10:09:33 AM
APPROVED.
NOTES: NOTES ARE ACCIDENTALLY DOUBLED.
|
|
| 10/22/2026 | R:FINAL BUILDING BASEMENT** | VINCE RAPONE | NOT APPROVED | eTRAKiT Inspection Request | 10/21/2026 12:59:34 PM
10/21/2026 12:59 PM BIANCO ELECTRIC LLC
Contact Christian Kingsley at 720-333-6089
Contact Name: BIANCO ELECTRIC LLC
Site Address: 4945 PERSIMMON LN
Phone: 3038623811
e-Mail: JBIANCO@BIANCO-ELECTRIC.COM
10/22/2026 10:37:48 AM
Plumbing incomplete
Electrical-
dryer and range need gfci protection
Kitchen small appliance need arc fault protection
Schedule final building when ready
|
|
| 10/27/2026 | R:FINAL BUILDING | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 10/26/2026 9:16:38 PM
10/26/2026 9:16 PM JKAL GROUP LLC
Contact Name: JKAL GROUP LLC
Site Address: 4945 PERSIMMON LN
Phone: 7202994733
e-Mail: JAY@JKALBUILD.COM
10/27/2026 1:53:48 PM
Final building approved
|
|