Permit No. 26-2328 Permit Type   RESIDENTIAL REMODEL Site Address   1590 FAIRFAX CT
CASTLE ROCK, CO 80104
Applied   06/27/2026 Applicant   R&M CONSTRUCTION SERVICES
Approved   07/20/2026 Owner   CHRISTOPHER AND BIANCA LARSON REVOCABLE TRUST
Issued   07/24/2026 Contractor  
Parent Permit No.   Description   KITCHEN REMODEL
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 07/27/2026R:ROUGH ELECTRICALSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request7/24/2026 11:48:37 AM 7/24/2026 11:48 AM R&M CONSTRUCTION SERVICES Contact Name: R&M CONSTRUCTION SERVICES Site Address: 1590 FAIRFAX CT Phone: 7203223659 e-Mail: Mark@RMCS5280.com 7/27/2026 9:55:20 AM Rough electrical inspection not approved 1. No town approved plans on site. Have plans and inspection card on site for next inspection 2. Update countertop receptacle spacing per NEC 2023. Castle rock amendment can only have four receptacles on one small appliance circuit 3. Missing future island power if planning to pull off microwave or dishwasher please have instruction manual on both to verify that circuit is not overloaded 4. Current lighting does not match the plans or has not been installed at this time if changes have been made per plans please update plans and submit to the town of Castle rock. Recall rough electrical inspection when corrections are made Note It appears that a new fireplace has been/being installed at this time of inspection plans do not show new fireplace. This needs to be added to the plans.

 07/27/2026R:ROUGH FRAMECOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request7/24/2026 11:48:37 AM 7/24/2026 11:48 AM R&M CONSTRUCTION SERVICES Contact Name: R&M CONSTRUCTION SERVICES Site Address: 1590 FAIRFAX CT Phone: 7203223659 e-Mail: Mark@RMCS5280.com 7/27/2026 2:50:03 PM 1. Electrical was not approved 2. Missing exhaust fan and fan will be at 400 cfm so you will need make up air added. 3. Remove gas line for the kitchen stove on the plans.

 07/27/2026R:INSULATIONCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request7/24/2026 11:48:38 AM 7/24/2026 11:48 AM R&M CONSTRUCTION SERVICES Contact Name: R&M CONSTRUCTION SERVICES Site Address: 1590 FAIRFAX CT Phone: 7203223659 e-Mail: Mark@RMCS5280.com 7/27/2026 2:50:05 PM Approved Insulation was not taken out or added from original.

 08/04/2026R:ROUGH FRAMESHAWN VALENZUELAAPPROVEDSEE BIS8/3/2026 2:55:45 PM 8/3/2026 2:55 PM R&M CONSTRUCTION SERVICES Contact Name: R&M CONSTRUCTION SERVICES Site Address: 1590 FAIRFAX CT Phone: 7203223659 e-Mail: Mark@RMCS5280.com 8/4/2026 9:42:08 AM Rough frame inspection approved Will verify at final inspection exhaust fan is under 400 cfm

 08/04/2026R:ROUGH ELECTRICALSHAWN VALENZUELAAPPROVEDSEE BIS8/3/2026 2:55:45 PM 8/3/2026 2:55 PM R&M CONSTRUCTION SERVICES Contact Name: R&M CONSTRUCTION SERVICES Site Address: 1590 FAIRFAX CT Phone: 7203223659 e-Mail: Mark@RMCS5280.com 8/4/2026 9:42:11 AM Rough electrical inspection approved Note Will verify kitchen counter top receptacle spacing at final electrical inspection Will verify that any electrical circuit that has been extended or altered is brought up to current codes arc fault gfci protection

 10/06/2026R:FINAL BUILDINGSHAWN VALENZUELAAPPROVED7209806501 - COME AFTER 9:1510/5/2026 9:55:01 AM HOMEOWNER 10/6/2026 10:37:53 AM Final building inspection approved Notes Kitchen exhaust fan is under 400 cfm