| 09/16/2026 | TRAC:TEMPORARY CONSTRUCTION METER | VINCE RAPONE | NOT APPROVED | eTRAKiT Inspection Request | 9/15/2026 8:31:51 AM
9/15/2026 8:31 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7296105596
e-Mail: sharkins@drbgroup.com
9/16/2026 11:14:22 AM
Can not use ground rods
Run equivalent through flex - core will bond in transformer
Reschedule
|
|
| 09/16/2026 | TRAC:GROUND PLUMBING | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 9/16/2026 2:32:18 AM
9/16/2026 2:32 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
9/16/2026 2:57:09 PM
Approved
|
|
| 09/18/2026 | TRAC:TEMPORARY CONSTRUCTION METER | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 9/17/2026 4:06:39 PM
9/17/2026 4:06 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
9/18/2026 10:14:09 AM
Temporary construction meter approved
|
|
| 10/13/2026 | TRAC:POST REAR | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 10/13/2026 2:59:09 AM
10/13/2026 2:59 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/13/2026 2:21:43 PM
Missing post caps
|
|
| 10/13/2026 | TRAC:PORCH POST FRONT | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 10/13/2026 2:58:22 AM
10/13/2026 2:58 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup,com
10/13/2026 2:21:48 PM
Missing post caps
|
|
| 10/13/2026 | TRAC:WALL BRACING SHEATHING | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 10/13/2026 2:56:09 AM
10/13/2026 2:56 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup,com
10/13/2026 2:21:51 PM
Missing 2x2 washers at the portal frame.
Ok to wrap house for weather resistive.
|
|
| 10/15/2026 | TRAC:POST REAR | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 10/14/2026 5:21:05 PM
10/14/2026 5:21 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/15/2026 10:30:38 AM
APPROVED.
|
|
| 10/15/2026 | TRAC:PORCH POST FRONT | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 10/14/2026 5:20:14 PM
10/14/2026 5:20 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/15/2026 10:30:45 AM
APPROVED.
|
|
| 10/15/2026 | TRAC:WALL BRACE_SHEATH | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 10/14/2026 5:19:26 PM
10/14/2026 5:19 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/15/2026 10:45:08 AM
APPROVED.
|
|
| 11/12/2026 | TRAC:REQUEST PRE ROUGH DOC | BUILDING COUNTER | APPROVED | CB | 11/10/2026 6:07:16 PM
11/10/2026 6:07 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
|
|
| 11/13/2026 | TRAC:ROUGH ELECTRICAL | SHAWN VALENZUELA | NOT APPROVED | eTRAKiT Inspection Request | 11/12/2026 12:48:53 PM
11/12/2026 12:48 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
11/13/2026 11:14:57 AM
Rough electrical inspection, not approved
1. Secondary entering meter housing are loose
2. Box missing for 220 V receptacle in garage
3. Switch leg not landed in exhaust fan in basement bathroom
Recall inspection when all corrections are completed
Notes
Cold water bond located in basement north bedroom required to be accessible at final
|
|
| 11/13/2026 | TRAC:ROUGH FRAME | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 11/12/2026 12:47:53 PM
11/12/2026 12:47 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
11/13/2026 1:07:04 PM
NOT APPROVED-
1) DAMAGED SHEATHING IN GARAGE SHEAR WALL / REAR GARAGE ELEVATION.
2) DAMAGED BOTTOM CORD OF A8 ROOF TRUSS/ IN MASTER BEDROOM BY MECHANICAL CLOSET.
3) DAMAGED KING STUD AT BALLOON FRAMING/ TOP OF STUD, FRONT DOOR.
4) WATER TREE IN BASEMENT MECHANICAL ROOM NOT BONDED.
5) CUT DOUBLE TOP PLATE IN LOAD BEARING WALL FOR MECHANICAL PENETRATION/ IN KITCHEN. LOOKING FOR CLARIFICATION FROM A COLORADO DESIGN PROFESSIONAL..
6) EXHAUST PIPE DIAMETER IS TO SMALL BASED OFF OF THE AMOUNT OF BENDS & TOTAL PIPE LENGTH.
7) COMPLETE RGH ELECTRICAL.
RGH PLUMBING- NOT APPROVED.
RGH MECHANICAL- NOT APPROVED.
GAS ON TEST - OK.
ISO-
FURNACE ONE
FURNACE TWO
GREAT ROOM FIREPLACE
KITCHEN RANGE
WATER HEATER
NOTE: FINISHED BASEMENT/ REAR LID & PORCH.
|
|
| 11/17/2026 | TRAC:RE ROUGH ELECTRICAL | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 11/16/2026 1:13:09 PM
11/16/2026 1:13 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
11/17/2026 10:33:01 AM
Rough electrical inspection approved
All corrections have been completed
OK to release electrical meter
Notes
Cold water bond located in basement north bedroom to be accessible at final
|
|
| 11/17/2026 | TRAC:RE ROUGH FRAME | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 11/16/2026 1:12:18 PM
11/16/2026 1:12 PM DRB GROUP COLORADO LLC
Letter pending for cut top plate in kitchen
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
11/17/2026 12:23:56 PM
NOT APPROVED-
1) DAMAGED SHEATHING IN GARAGE SHEAR WALL / REAR GARAGE ELEVATION.
2) WATER TREE IN BASEMENT MECHANICAL ROOM NOT BONDED TO BE DONE BEFORE FINAL.
3) CUT DOUBLE TOP PLATE IN LOAD BEARING WALL FOR MECHANICAL PENETRATION/ IN KITCHEN. LOOKING FOR CLARIFICATION FROM A COLORADO DESIGN PROFESSIONAL..
RGH MECHANICAL NOT APPROVED.
RGH PLUMBING APPROVED.
NOTE: OK TO INSULATE.
|
|
| 11/20/2026 | TRAC:INSULATION | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 11/18/2026 9:28:17 AM
11/18/2026 9:28 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
11/20/2026 7:37:31 AM
Inspector VIRA changed the inspection assignment from VIRA to SHVA
11/20/2026 11:11:27 AM
Insulation inspection approved
|
|
| 11/20/2026 | TRAC:RE ROUGH FRAME | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 11/18/2026 9:27:40 AM
11/18/2026 9:27 AM DRB GROUP COLORADO LLC
repair letter completed
Contact Name: DRB GROUP COLORADO LLC
Site Address: 1025 COAL BANK TRL
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
11/20/2026 11:11:30 AM
Rough frame inspection approved
Engineer clarification letter has been uploaded to permit
All other corrections have been completed
Note
Cold water bond is located in north basement bedroom required to be accessible at final
|
|