| 08/28/2026 | TRAC:GROUND PLUMBING | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 8/27/2026 8:12:30 AM
8/27/2026 8:12 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 4994 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
8/28/2026 12:23:30 PM
APPROVED.
|
|
| 09/16/2026 | TRAC:WALL BRACING SHEATHING | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 9/15/2026 2:36:24 PM
9/15/2026 2:36 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 4994 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
9/16/2026 11:14:20 AM
Wall bracing approved
|
|
| 10/02/2026 | TRAC:WEATHER RESISTIVE BARRIER | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 10/1/2026 9:21:29 AM
10/1/2026 9:21 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 4994 JOLITY CT
Phone: 7206105596
e-Mail: coloradopermits@drbgroup.com
10/2/2026 1:34:06 PM
Weather resistive barrier inspection approved
|
|
| 10/02/2026 | TRAC:FIRE RESISTIVE | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 10/1/2026 9:20:45 AM
10/1/2026 9:20 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 4994 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/2/2026 1:34:08 PM
Fire resistive inspection approved
Notes
No burn spray in basement only required in unfinished areas as finished area will be protected by drywall
|
|
| 10/05/2026 | TRAC:REQUEST PRE ROUGH DOC | BUILDING COUNTER | APPROVED | eTRAKiT Inspection Request | 10/2/2026 8:40:44 AM
10/2/2026 8:40 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 4994 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
|
|
| 10/06/2026 | TRAC:ROUGH ELECTRICAL | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 10/5/2026 11:31:40 AM
10/5/2026 11:31 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 4994 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/6/2026 9:54:25 AM
Rough electrical approved
|
|
| 10/06/2026 | TRAC:ROUGH FRAME | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 10/5/2026 11:32:29 AM
10/5/2026 11:32 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 4994 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/6/2026 2:06:29 PM
NOT APPROVED-
1) MISSING FIRE BLOCKING AT DOUBLE TOP PLATE FOR ELECTRICAL PENETRATION/ KITCHEN PANTRY.
2) MISSING MECHANICAL HANGERS AT J1 TRUSSES/ RIGHT REAR ELEVATION PER PLANS PAGE S2.21
3) MISSING FIRE BLOCKING FOR FLOOR PENETRATIONS / IN BASEMENT.
4) MISSING STEEL MONO POST FOR STEEL I BEAM / BASEMENT NEXT TO BASEMENT STAIRS.
****5) WILL NEED A STAMPED (OBSERVATION LETTER) FROM A COLORADO DESIGN PROFESSIONAL FOR MISSED PLACE STRUCTURAL PAD/ NEXT TO BASEMENT-STAIRS****
REST OF RGH FRAME - OK.
GAS ON TEST - OK.
RGH PLUMBING-OK.
RGH MECHANICAL- OK.
ISO
FURNACE
WATER HEATER
GREAT ROOM FIREPLACE
RANGE
NOTE: UNFINISHED PARTIAL BASEMENT/ REAR LID & PORCH.
|
|
| 10/08/2026 | TRAC:RE ROUGH FRAME | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 10/7/2026 3:36:13 PM
10/7/2026 3:36 PM DRB GROUP COLORADO LLC
Letter pending mono post repair - L:ooking for the OK to insulate
Contact Name: DRB GROUP COLORADO LLC
Site Address: 4994 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/8/2026 1:02:35 PM
NOT APPROVED-
1) ATTACH STAMPED ( OBSERVATION LETTER) STRUCTURAL PAD FOR STILL ON POST BY STAIRS IN BASEMENT.
REST OF RGH FRAME - OK.
|
|
| 10/13/2026 | TRAC:INSULATION | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 10/12/2026 10:32:51 AM
10/12/2026 10:32 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 4994 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/13/2026 12:18:54 PM
Insulation inspection approved
|
|
| 10/20/2026 | TRAC:SHEAR WALL DRYWALL | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 10/19/2026 11:51:38 AM
10/19/2026 11:51 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 4994 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/20/2026 11:55:50 AM
Shear wall/ drywall inspection approved
|
|
| 10/20/2026 | TRAC:RE ROUGH FRAME | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 10/19/2026 11:50:17 AM
10/19/2026 11:50 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 4994 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/20/2026 11:55:53 AM
Rough frame inspection approved
All corrections have been completed
Electrical, plumbing, mechanical approved
|
|
| 10/21/2026 | TRAC:LATH STONE BRICK TIE | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 10/20/2026 10:12:46 AM
10/20/2026 10:12 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 4994 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/21/2026 10:49:27 AM
Lath inspection approved
|
|