| 09/04/2026 | TRAC:GROUND PLUMBING | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 9/3/2026 1:04:19 PM
9/3/2026 1:04 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
9/4/2026 1:24:51 PM
APPROVED-
NOTE: EXPOSED FOUNDATION WALL STEEL WHERE COPPER SUPPLY LINE WAS RELOCATED DUE TO FOUNDATION WALL STEEL REINFORCEMENT.
PLEASE CHECK AT NEXT INSPECTION THAT ITEM HAS BEEN CORRECTED.
|
|
| 09/16/2026 | TRAC:TEMPORARY CONSTRUCTION METER | SHAWN VALENZUELA | CANCEL | eTRAKiT Inspection Request | 9/15/2026 8:27:58 AM
9/15/2026 8:27 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
9/16/2026 7:29:28 AM
PER SCOTT
Electricians were not able to set pole
|
|
| 09/17/2026 | TRAC:TEMPORARY CONSTRUCTION METER | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 9/16/2026 6:10:24 PM
9/16/2026 6:10 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: shark1342@comcast.net
9/17/2026 1:03:16 PM
Temporary construction inspection approved
|
|
| 10/02/2026 | TRAC:POST REAR | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 10/1/2026 9:39:16 AM
10/1/2026 9:39 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/2/2026 12:43:38 PM
APPROVED.
|
|
| 10/02/2026 | TRAC:PORCH POST FRONT | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 10/1/2026 9:38:22 AM
10/1/2026 9:38 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/2/2026 12:43:40 PM
APPROVED.
|
|
| 10/02/2026 | TRAC:WALL BRACING SHEATHING | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 10/1/2026 9:37:26 AM
10/1/2026 9:37 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
10/2/2026 1:33:58 PM
Wall bracing inspection approved
|
|
| 11/04/2026 | TRAC:ROUGH ELECTRICAL | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 11/3/2026 2:11:16 PM
11/3/2026 2:11 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
11/4/2026 2:32:00 PM
Rough electrical inspection approved
Note
Fireplace not installed at time of inspection
120v wire installed ready to land in fireplace with bushing on wire
|
|
| 11/04/2026 | TRAC:WEATHER RESISTIVE BARRIER | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 11/3/2026 2:12:19 PM
11/3/2026 2:12 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
11/4/2026 3:29:21 PM
APPROVED.
|
|
| 11/04/2026 | TRAC:FIRE RESISTIVE | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 11/3/2026 2:12:59 PM
11/3/2026 2:12 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
11/4/2026 3:29:23 PM
APPROVED.
|
|
| 11/04/2026 | TRAC:ROUGH FRAME | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 11/3/2026 2:10:22 PM
11/3/2026 2:10 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
11/4/2026 3:29:26 PM
NOT APPROVED-
1) GREAT ROOM FIREPLACE & DUCTING NOT INSTALLED AT TIME OF RGH FRAME.
2) MISSING CORRECT NUMBER OF LEDGER CONNECTIONS AT BASEMENT STAIR LANDING.
3) MISSING EXHAUST CONNECTION / IN BASEMENT BATHROOM. ( IF ELBOW IS INSTALLED EXHAUST DIAMETER SIZE IS TOO SMALL.).
4) MISSING FIRE BLOCKING IN CONCEALED SPACE / IN BASEMENT BY BATHROOM.
5) WET VENT FOR SECOND FLOOR FULL BATHROOM LEFT ELEVATION DOES NOT COMPLY WITH WET-VENT & DRY-VENT PER CODE CHAPER 31.
RGH MECHANICAL- NOT APPROVED.
GAS ON TEST - OK.
ISO
GREAT ROOM FIREPLACE
FURNACE
2ND FURNACE
DRYER
NOTE: PARTIAL FINISHED BASEMENT/ CRAWL SPACE / REAR LID.
|
|
| 11/09/2026 | TRAC:RE ROUGH FRAME | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 11/6/2026 1:47:02 PM
11/6/2026 1:47 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
11/9/2026 1:55:10 PM
APPROVED.
|
|
| 11/12/2026 | TRAC:INSULATION | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 11/10/2026 6:08:28 PM
11/10/2026 6:08 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
11/12/2026 11:44:53 AM
APPROVED.
|
|
| 11/19/2026 | TRAC:SHEAR WALL DRYWALL | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 11/19/2026 2:27:16 AM
11/19/2026 2:27 AM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: shark1342@comcast.net
11/19/2026 12:59:43 PM
Approved
|
|
| 11/20/2026 | TRAC:LATH STONE BRICK TIE | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 11/19/2026 1:01:07 PM
11/19/2026 1:01 PM DRB GROUP COLORADO LLC
Contact Name: DRB GROUP COLORADO LLC
Site Address: 5060 JOLITY CT
Phone: 7206105596
e-Mail: sharkins@drbgroup.com
11/20/2026 11:11:24 AM
Lath inspection approved
|
|