Permit No. 26-2016 Permit Type   RESIDENTIAL ACCESSORY STRUCTURE Site Address   4324 MANORBRIER CIR
CASTLE ROCK, CO 80104
Applied   06/05/2026 Applicant   Rosa Hammerquist
Approved   08/03/2026 Owner   HAMMERQUIST FAMILY TRUST
Issued   08/03/2026 Contractor  
Parent Permit No.   Description   DECK
  Notes   New deck
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 08/05/2026R:CAISSONSSHAWN VALENZUELANOT APPROVEDcaissons inspection8/3/2026 6:02:52 PM 8/3/2026 6:02 PM Rosa Hammerquist Contact Name: Rosa Hammerquist Site Address: 4324 MANORBRIER CIR Phone: 3126562455 e-Mail: rosahammerquist@gmail.com 8/5/2026 9:43:16 AM Caisson inspection not approved 1. One of 4 caisson has been dug to the appropriate depth north east corner of deck. The other 3 caissons per contractor have hit foundation footing. Contractor has new set of plans on site showing the other 3 caisson as being deleted. Please upload new plans to the town of castle rock so they can be reviewed and approved. Will need engineer clarification stating that these are indeed foundation, footings, and adequate to support the deck. Notes Ok to pour 1 caisson at your own risk as these new plans have not been reviewed by the town of castle rock. Reschedule caisson inspection when corrections are completed.

 08/24/2026R:CAISSONSSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/21/2026 4:48:22 PM 8/21/2026 4:48 PM Rosa Hammerquist Contact Name: Rosa Hammerquist Site Address: 4324 MANORBRIER CIR Phone: 3126562455 e-Mail: rosahammerquist@gmail.com 8/24/2026 9:38:25 AM Caisson inspection approved Verify bottom post connection Simpson strong tie abw66z esr- 2523 at 3 6x6 locations

 08/25/2026R:ROUGH DECKJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request8/24/2026 9:34:49 AM 8/24/2026 9:34 AM Rosa Hammerquist Contact Name: Rosa Hammerquist Site Address: 4324 MANORBRIER CIR Phone: 3126562455 e-Mail: rosahammerquist@gmail.com 8/25/2026 12:19:36 PM NOT APPROVED- 1) MISSING POST CAPS / POST CAPS TO BE IN PAIRS PER MANUFACTURER. 2) REST OF RGH DECK INSPECTION-OK. NOTE: RE RGH DECK & DECK FINAL CAN BE SCHEDULED AT THE SAME TIME.

 10/06/2026B:RE_RGH FRAMEJOE CARBAUGHAPPROVED10/6/2026 1:16:39 PM APPROVED.

 10/06/2026R:FINAL DECK**JOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request10/5/2026 11:56:09 AM 10/5/2026 11:56 AM Rosa Hammerquist final frame and final deck needed Contact Name: Rosa Hammerquist Site Address: 4324 MANORBRIER CIR Phone: 3126562455 e-Mail: rosahammerquist@gmail.com 10/6/2026 1:16:42 PM NOT APPROVED- 1) MISSING REQUIRED CONTINUES HANDRAIL FOR 4 RISERS OR MORE. 2) STAIR POST BASE CONNECTIONS INCOMPLETE. 3) REST OF FINAL - OK. NOTE: RECALL FINAL INSPECTION WHEN ITEMS HAVE BEEN CORRECTED.

 10/22/2026R:FINAL DECK**JOE CARBAUGHAPPROVEDeTRAKiT Inspection Request10/21/2026 7:48:01 AM 10/21/2026 7:48 AM Rosa Hammerquist Contact Name: Rosa Hammerquist Site Address: 4324 MANORBRIER CIR Phone: 3126562455 e-Mail: rosahammerquist@gmail.com 10/22/2026 1:55:28 PM APPROVED.