Permit No. 26-1899 Permit Type   RESIDENTIAL TRACT HOME Site Address   705 STICKSEED DR
CASTLE ROCK, CO 80104
Applied   05/29/2026 Applicant   TOLL BROTHERS
Approved   06/09/2026 Owner   TOLL SOUTHWEST LLC C/O PROPERTY TAX DEPARTMENT
Issued   06/23/2026 Contractor  
Parent Permit No.   Description   NEW SINGLE FAMILY DETACHED RESIDENCE W/CUSTOM TRUSSES
  Notes   705 Stickseed
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 07/08/2026TRAC:TEMPORARY CONSTRUCTION METERSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request7/7/2026 10:25:00 AM 7/7/2026 10:25 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Boeckers Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: JBoeckers@tollbrothers.com 7/8/2026 8:50:40 AM Temporary construction meter inspection not approved 1. No inspection card on site. Please reschedule inspection when corrections are completed

 07/14/2026TRAC:TEMPORARY CONSTRUCTION METERSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request7/13/2026 3:53:38 PM 7/13/2026 3:53 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Boeckers Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: jboeckers@tollbrothers.com 7/14/2026 12:40:17 PM Construction meter inspection approved

 07/15/2026TRAC:GROUND PLUMBINGJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request7/13/2026 4:07:20 PM 7/13/2026 4:07 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Boeckers Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: jboeckers@tollbrothers.com 7/15/2026 11:52:26 AM APPROVED. NOTE: NO PLUMBING PENETRATIONS THROUGH FOUNDATION STEM WALL AT TIME OF GROUND PLUMBING INSPECTION.

 09/01/2026TRAC:WALL BRACING SHEATHINGSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/31/2026 12:35:17 PM 8/31/2026 12:35 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Boeckers Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: JBoeckers@tollbrothers.com 9/1/2026 2:49:28 PM Wall brace and sheathing inspection approved

 09/18/2026TRAC:REQUEST PRE ROUGH DOCBUILDING COUNTERAPPROVEDCB9/17/2026 9:34:11 AM 9/17/2026 9:34 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Boeckers Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: jboeckers@tollbrothers.com

 09/18/2026TRAC:ROUGH DECKMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request9/17/2026 4:52:35 PM 9/17/2026 4:52 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Boeckers Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: JBoeckers@tollbrothers.com

 09/18/2026TRAC:POST REARMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request9/17/2026 4:52:35 PM 9/17/2026 4:52 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Boeckers Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: JBoeckers@tollbrothers.com

 09/18/2026TRAC:PORCH POST FRONTMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request9/17/2026 4:52:34 PM 9/17/2026 4:52 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Boeckers Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: JBoeckers@tollbrothers.com

 09/18/2026TRAC:FIRE RESISTIVEMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request9/17/2026 4:52:36 PM 9/17/2026 4:52 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Boeckers Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: JBoeckers@tollbrothers.com 9/18/2026 1:01:11 PM 1. Left, east, gable needs one sheet of drywall removed so second row and staggered seams can be verified. 2. Right, north west corner has unstaggered seams. 3. Right gable has no evidence of staggered seams. 4. Right rear, south west, corner is missing 2 layers of drywall.

 09/18/2026R:WEATHER RESISTIVE BARRIERMARTIN MAGERSAPPROVED

 09/24/2026TRAC:ROUGH ELECTRICALSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request9/22/2026 3:39:01 PM 9/22/2026 3:39 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: jboeckers@tollbrothers.com 9/24/2026 2:07:11 PM Rough electrical inspection not approved 1. Laterals installed for line side of meter are loose a phase and neutral 2. Add receptacle to the right of back door deck for 6/12 spacing 3. Cold water bond needs to bond below the lowest shut off Recall inspection when corrections are completed

 09/24/2026TRAC:ROUGH FRAMEJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request9/22/2026 3:39:02 PM 9/22/2026 3:39 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: jboeckers@tollbrothers.com 9/24/2026 2:21:24 PM NOT APPROVED- 1) MISSING SUPPORTS FOR GARAGE SHED ROOF. 2) MISSING HIGH STRENGTH APOXY FOR METAL SHIMS/ IN GARAGE RIGHT ELEVATION. 3) NOT DRIED IN / MISSING REAR WINDOWS AT DECK. 4) MISSING CORRECT NUMBER OF MECHANICAL ATTACHMENT FOR BASEMENT STAIR LANDING LEDGER. 5) COMPLETE RGH ELECTRICAL. RGH PLUMBING- OK. RGH MECHANICAL- OK. GAS ON TEST - OK. ISO- FURNACE WATER-HEATER DRYER KITCHEN VENT HOOD NOTE: UNFINISHED BASEMENT/ REAR LID & PORCH.

 09/28/2026TRAC:RE ROUGH ELECTRICALSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request9/25/2026 2:32:36 PM 9/25/2026 2:32 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Boeckers Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: jboeckers@tollbrothers.com 9/28/2026 10:05:16 AM Rough electrical inspection approved All corrections have been completed

 09/28/2026TRAC:RE ROUGH FRAMEJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/25/2026 2:32:36 PM 9/25/2026 2:32 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Boeckers Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: jboeckers@tollbrothers.com 9/28/2026 12:33:15 PM APPROVED.

 09/28/2026TRAC:INSULATIONJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/25/2026 2:32:36 PM 9/25/2026 2:32 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Boeckers Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: jboeckers@tollbrothers.com 9/28/2026 12:33:17 PM APPROVED.

 10/05/2026TRAC:SHEAR WALL DRYWALLVINCE RAPONEAPPROVEDeTRAKiT Inspection Request10/2/2026 12:44:18 PM 10/2/2026 12:44 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: Jason Boeckers Site Address: 705 STICKSEED DR Phone: 3037096246 e-Mail: jboeckers@tollbrothers.com 10/5/2026 10:29:18 AM Shear wall approved