| 07/22/2026 | R:ROUGH PLUMBING | MARTIN MAGERS | NOT APPROVED | Rough plumbing and gas inspection. | 7/21/2026 12:56:02 PM
7/21/2026 12:56 PM HONEYCOMB CONSTRUCTION LLC
I will be on site. Homowner is also on site. Work area is immediately inside the front door. Lockbox code if needed is 4158 and located next to the front door.
Contact Name: Alex Grisanti
Site Address: 455 ROSE QUARTZ PL
Phone: 5025534247
e-Mail: ALEX@HONEYCOMBCOLORADO.COM
7/23/2026 7:06:53 AM
1. No town approved plans on site.
Air and water tests for new water lines And drain lines as well as 3" drains moved from upstairs. Are approved.
|
|
| 07/22/2026 | R:GAS PIPE AIR TEST | MARTIN MAGERS | NOT APPROVED | Small FP relocation. New Stove location. | 7/21/2026 12:56:02 PM
7/21/2026 12:56 PM HONEYCOMB CONSTRUCTION LLC
I will be on site. Homowner is also on site. Work area is immediately inside the front door. Lockbox code if needed is 4158 and located next to the front door.
Contact Name: Alex Grisanti
Site Address: 455 ROSE QUARTZ PL
Phone: 5025534247
e-Mail: ALEX@HONEYCOMBCOLORADO.COM
7/23/2026 7:06:55 AM
1. No town approved plans on site.
2. Manifold is not sized correctly for all the pipes attached to it. See pictures.
Note gas test to 3/4" inch line to range approved.
|
|
| 07/28/2026 | R:ROUGH ELECTRICAL | VINCE RAPONE | APPROVED | Contractor will be on site | 7/27/2026 12:22:16 PM
7/27/2026 12:22 PM HONEYCOMB CONSTRUCTION LLC
New steel beam installed in opening. Engineer plans are on site for reference. The rest of the changes to framing are minimal and not on load bearing walls.
Contact Name: HONEYCOMB CONSTRUCTION LLC
Site Address: 455 ROSE QUARTZ PL
Phone: 5025534247
e-Mail: ALEX@HONEYCOMBCOLORADO.COM
7/28/2026 11:06:19 AM
Rough electrical approved
|
|
| 07/28/2026 | R:ROUGH FRAME | MARTIN MAGERS | NOT APPROVED | Contractor will be on site | 7/27/2026 12:22:16 PM
7/27/2026 12:22 PM HONEYCOMB CONSTRUCTION LLC
New steel beam installed in opening. Engineer plans are on site for reference. The rest of the changes to framing are minimal and not on load bearing walls.
Contact Name: HONEYCOMB CONSTRUCTION LLC
Site Address: 455 ROSE QUARTZ PL
Phone: 5025534247
e-Mail: ALEX@HONEYCOMBCOLORADO.COM
7/29/2026 7:08:09 AM
1. Fireplace on plans, not installed. If on a different permit , please supply permit number.
2. No fire blocking installed.
3. Please upload install manual for hood to help determine if make up air is sized correctly. .
4. Gas iso not approved in review and manifold not sized correctly. See picture.
5. Center of triple posting for I beam on the front ent is short, please shim.
6. Back side of I beam does not rest in triple 2x6 as shown on plans. It rests in a header with about 3 in of bearing. All posting is covered with drywall. Please have engineer evaluate if posting.
7. Kicker not installed to plan.
8. Missing all posting Squash blocking, to foundation at back exterior.
|
|
| 08/06/2026 | R:RE_ROUGH FRAME | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 8/5/2026 2:47:56 PM
8/5/2026 2:47 PM HONEYCOMB CONSTRUCTION LLC
Contact Name: HONEYCOMB CONSTRUCTION LLC
Site Address: 455 ROSE QUARTZ PL
Phone: 5025534247
e-Mail: ALEX@HONEYCOMBCOLORADO.COM
8/6/2026 3:29:40 PM
1. Fire place missing gas line, and excess-able shut off
2. Fireplace missing electrical connection.
3. Missing non combustible 7" above fireplace.
4. Frame in chase with 1" clearance around fireplace exhaust.
5. BTU for fireplace in living room is 42,500. Listed as 30,000 BTUs on isometric submitted for review.
6. Gas Manifold is under sized see picture
7. Make up air for the 900 cfm exhaust hood must be engineered per manufactures install manual.
Excepted engineers letter and verified all repairs.
|
|
| 11/06/2026 | R:FNL BUILDING | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 11/5/2026 7:42:51 AM
11/5/2026 7:42 AM HONEYCOMB CONSTRUCTION LLC
Contact Name: HONEYCOMB CONSTRUCTION LLC
Site Address: 455 ROSE QUARTZ PL
Phone: 5025534247
e-Mail: ALEX@HONEYCOMBCOLORADO.COM
11/6/2026 10:48:18 AM
No answer at the door.
|
|
| 11/06/2026 | R:FINAL ELECTRICAL | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 11/5/2026 7:42:51 AM
11/5/2026 7:42 AM HONEYCOMB CONSTRUCTION LLC
Contact Name: HONEYCOMB CONSTRUCTION LLC
Site Address: 455 ROSE QUARTZ PL
Phone: 5025534247
e-Mail: ALEX@HONEYCOMBCOLORADO.COM
11/6/2026 11:56:50 AM
Final electrical approved
|
|
| 11/19/2026 | R:FINAL BUILDING BASEMENT** | MARTIN MAGERS | NOT APPROVED | DAVID 3375784700 | 11/19/2026 7:41:48 AM
Inspector VIRA changed the inspection assignment from VIRA to MAM2
11/19/2026 10:32:05 AM
1. Make up air damper not connected.
2. Missing manual for clearance if mantel.
Items left from from rough frame
4. Frame in chase with 1%34 clearance around fireplace exhaust.
5. BTU for fireplace in living room is 42,500. Listed as 30,000 BTUs on isometric submitted for review.
|
|