11/21/2026
10:51 PM
 
Permit No. 26-1871 Permit Type   RESIDENTIAL TRACT HOME Site Address   1051 COAL BANK TRL
CASTLE ROCK, CO 80104
Applied   05/27/2026 Applicant   DRB GROUP COLORADO LLC
Approved   06/05/2026 Owner   GH COLORADO LLC
Issued   06/09/2026 Contractor  
Parent Permit No.   Description   NEW SINGLE FAMILY DETACHED RESIDENCE
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 07/15/2026TRAC:GROUND PLUMBINGJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request7/14/2026 3:49:03 PM 7/14/2026 3:49 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 7/15/2026 11:52:21 AM APPROVED.

 08/03/2026TRAC:WALL BRACING SHEATHINGCOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request8/3/2026 3:02:40 AM 8/3/2026 3:02 AM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 8/3/2026 11:52:59 AM 1. Rear of the house at the east side missing nailing in both hold Downs 2. Inside shear by the front door missing edge 3 in nailing at the corner 3. Detail 2/ s4.10 is not completed correctly it calls for CS to wrapped around beam and up 2in on each

 08/04/2026TRAC:POST REARCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request8/3/2026 11:23:47 AM 8/3/2026 11:23 AM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 8/4/2026 11:11:56 AM Approved

 08/04/2026TRAC:PORCH POST FRONTCOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request8/3/2026 11:23:07 AM 8/3/2026 11:23 AM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 8/4/2026 11:11:58 AM 1. Cannot verify both 2 2x6 headers or king and trim at the front side.

 08/04/2026TRAC:WALL BRACING SHEATHINGCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request8/3/2026 11:22:26 AM 8/3/2026 11:22 AM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 8/4/2026 11:12:01 AM Approved

 08/07/2026TRAC:PORCH POST FRONTSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/6/2026 3:38:35 PM 8/6/2026 3:38 PM DRB GROUP COLORADO LLC re-inspection Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 8/7/2026 12:17:36 PM Porch post front inspection approved

 08/19/2026TRAC:WEATHER RESISTIVE BARRIERJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request8/18/2026 2:43:27 PM 8/18/2026 2:43 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 8/19/2026 11:37:21 AM Inspector SHVA changed the inspection assignment from SHVA to JOCA 8/19/2026 12:46:08 PM APPROVED.

 08/19/2026TRAC:FIRE RESISTIVEJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request8/18/2026 2:42:34 PM 8/18/2026 2:42 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 8/19/2026 11:37:39 AM Inspector SHVA changed the inspection assignment from SHVA to JOCA 8/19/2026 12:46:11 PM APPROVED. NOTE: NO BURN IN MECHANICAL ROOM ONLY.

 08/28/2026TRAC:REQUEST PRE ROUGH DOCBUILDING COUNTERAPPROVEDCB8/27/2026 8:17:50 AM 8/27/2026 8:17 AM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com

TRAC:RE ROUGH ELECTRICALVINCE RAPONEeTRAKiT Inspection Request8/30/2026 2:29:14 PM 8/30/2026 2:29 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com

 09/01/2026TRAC:ROUGH ELECTRICALSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/30/2026 2:32:36 PM 8/30/2026 2:32 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 9/1/2026 1:40:43 PM Rough electrical inspection approved Will verify at final ac disconnect have the proper clearance

 09/01/2026TRAC:ROUGH FRAMEJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request8/30/2026 2:33:28 PM 8/30/2026 2:33 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 9/1/2026 2:38:18 PM NOT APPROVED- 1) MISSING THERMAL PLY AT AND BELOW FOOT OF TUB/ MAIN LEVEL N/E BATHROOM. 2) MISSING FIRE-BLOCKING AT BOTTOM/ FLOOR THROUGH PENETRATION/ MAIN LEVEL N/E BATHROOM INNER WALL. 3) MISSING FIRE-BLOCKING AT BOTTOM PLATE / LEFT ELEVATION N/E WALL. 4) COMBUSTIBLE'S ON GREAT ROOM FIREPLACE. 5) MISSING FIRE-BLOCKING AT BOTTOM PLATE THROUGH PENETRATION/ LEFT ELEVATION/ SOUTH DINNING ROOM EAST WALL. 6) MISSING GABLE END TRUSS LATERAL BRACING/ REAR ELEVATION ABOVE REAR SLIDER. 7) NOT DRIED IN / RIGHT ELEVATION FRONT RIGHT BEDROOM/ OFFICE UP AT RIM. 8) MISSING CORRECT DIRECTION & NUMBER OF SQUASH BLOCKING IN FRONT ROOM BEDROOM/ OFFICE. 9) MISSING FIRE-BLOCKING FOR LID IN CONCEALED SPACE/ BASEMENT, N/E CORNER CLOSET. 10) ROCK AT BASE BETWEEN FLOATING / BASEMENT S/E BATHROOM. 11) MISSING FIRE-BLOCKING AT DOUBLE TOP PLATE ELECTRICAL PENETRATION/ BASEMENT AT BOXED OUT STEEL BEAM S/E BEDROOM CLOSET. REST OF RGH FRAME - OK. RGH MECHANICAL- OK . RGH PLUMBING- OK. GAS AIR ON TEST ISO- FURNACE SECOND FLOOR FURNACE GREAT ROOM FIREPLACE KITCHEN RANGE DRYER NOTE: CRAWL SPACE/ FINISHED BASEMENT/ REAR LID & PORCH.

 09/04/2026TRAC:RE ROUGH FRAMEMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request9/3/2026 1:06:34 PM 9/3/2026 1:06 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 9/4/2026 11:21:08 AM Inspector JOCA changed the inspection assignment from JOCA to MAM2 9/4/2026 2:30:36 PM New item, please fire block wall to ceiling in 3 bays in the basement bedroom closet.

 09/09/2026TRAC:INSULATIONJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/8/2026 9:39:08 AM 9/8/2026 9:39 AM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 9/9/2026 1:43:34 PM APPROVED.

 09/09/2026TRAC:RE ROUGH FRAMEJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/8/2026 9:38:12 AM 9/8/2026 9:38 AM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 9/9/2026 1:43:37 PM APPROVED.

 09/10/2026TRAC:LATH STONE BRICK TIEVINCE RAPONEAPPROVEDeTRAKiT Inspection Request9/9/2026 8:57:10 AM 9/9/2026 8:57 AM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 206105596 e-Mail: sharkins@drbgroup.com 9/10/2026 1:32:18 PM Lath approved

 09/16/2026TRAC:SHEAR WALL DRYWALLVINCE RAPONENOT APPROVEDeTRAKiT Inspection Request9/15/2026 8:22:24 AM 9/15/2026 8:22 AM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 9/16/2026 11:14:17 AM Shear wall incomplete Reschedule when ready

 09/17/2026TRAC:SHEAR WALL DRYWALLMARTIN MAGERSCANCELeTRAKiT Inspection Request9/16/2026 2:47:00 PM 9/16/2026 2:47 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 9/17/2026 10:18:46 AM cancel per scott 9/17/2026 11:06:26 AM Canceled per call with Scott.

 09/21/2026TRAC:SHEAR WALL DRYWALLSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request9/20/2026 10:49:19 AM 9/20/2026 10:49 AM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 9/21/2026 12:38:30 PM Shear wall drywall inspection not approved 1. Drywall in garage incomplete unfinished Notes Rest of house ok to start mud and tape recall inspection to verify garage is complete

 09/23/2026TRAC:SHEAR WALL DRYWALLCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request9/22/2026 1:49:54 PM 9/22/2026 1:49 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 9/23/2026 10:10:50 AM Approved

 10/12/2026D:REQ GRADE CERT REVJOHN GRAHNNOT APPROVEDUnable to edit PDF, see notes10/9/2026 9:09:42 AM 10/9/2026 9:09 AM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 10/12/2026 7:24:42 AM Unable to edit PDF, Missing sump pump location discharge point on GC.

 10/13/2026D:REQ GRADE CERT REVADAN RIVASAPPROVEDeTRAKiT Inspection Request10/12/2026 6:21:45 PM 10/12/2026 6:21 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com

 10/21/2026D:FINAL DESCJOHN GRAHNAPPROVEDeTRAKiT Inspection Request10/20/2026 8:43:19 AM 10/20/2026 8:43 AM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 10/21/2026 11:26:49 AM Front and backyard are fully landscaped.

 11/02/2026U:HE TOILETWILLIAM BROWNAPPROVEDeTRAKiT Inspection Request10/30/2026 2:23:31 PM 10/30/2026 2:23 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com

 11/03/2026U: METER SETGRANT TAYLORAPPROVED

 11/05/2026TRAC: FINAL DOC REVIEWBUILDING COUNTERAPPROVEDCB11/4/2026 12:44:54 PM 11/4/2026 12:44 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com

 11/13/2026TRAC:FINAL ELECTRICALSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request11/12/2026 1:04:11 PM 11/12/2026 1:04 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 11/13/2026 11:51:19 AM Final electrical inspection not approved 1. AC one breaker prior to inspection is in the off position. All breakers must be on. 2. hardwired hood requires breaker lock. 3. Light in the attic is not trimmed out. 4. Receptacle cover plate above fire place not installed Recall inspection when corrections are completed

 11/13/2026TRAC:FINAL BUILDINGJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request11/12/2026 1:03:09 PM 11/12/2026 1:03 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 11/13/2026 1:30:34 PM NOT APPROVED- 1) MISSING WEATHER CAULKING FOR BOTH AC PENETRATIONS/RIGHT ELEVATION. 2) MISSING ELECTRICAL WALL PLATE COVERS OVER FIREPLACE. 3) MISSING COVER UPPER DOOR FOR FURNACE UP STAIRS. 4) COMPLETE FINAL ELECTRICAL. NOTE: FINISHED PARTIAL BASEMENT & CRAWLSPACE/ TWO A/C INSTALLED/ REAR LID & PORCH.

 11/17/2026TRAC:RE FINAL ELECTRICALSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request11/16/2026 1:09:03 PM 11/16/2026 1:09 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 11/17/2026 10:21:57 AM Final electrical inspection approved All corrections have been completed

 11/17/2026TRAC:RE FINAL BUILDINGSHAWN VALENZUELAAPPROVED FOR COeTRAKiT Inspection Request11/16/2026 1:08:00 PM 11/16/2026 1:08 PM DRB GROUP COLORADO LLC Contact Name: DRB GROUP COLORADO LLC Site Address: 1051 COAL BANK TRL Phone: 7206105596 e-Mail: sharkins@drbgroup.com 11/17/2026 10:22:00 AM Final building inspection approved All corrections have been completed Electrical, plumbing, mechanical approved