10/05/2026
3:47 PM
 
Permit No. 26-1849 Permit Type   RESIDENTIAL TRACT HOME Site Address   5883 RENBARGER ST
CASTLE ROCK, CO 80104
Applied   05/26/2026 Applicant   TOLL BROTHERS
Approved   06/11/2026 Owner   TOLL BROTHERS
Issued   06/23/2026 Contractor  
Parent Permit No.   Description   NEW SINGLE FAMILY DETACHED RESIDENCE
  Notes   5883 Renbarger
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 07/01/2026TRAC:TEMPORARY CONSTRUCTION METERSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request6/30/2026 8:50:06 AM 6/30/2026 8:50 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 5883 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 7/1/2026 12:39:34 PM Construction meter inspection approved

 08/11/2026TRAC:GROUND PLUMBINGCOLBY RIGGINSCANCELeTRAKiT Inspection Request8/10/2026 9:44:06 AM 8/10/2026 9:44 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 5883 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 8/11/2026 7:29:20 AM Canceled per superintendent Steve.

 08/12/2026TRAC:GROUND PLUMBINGCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request8/11/2026 7:25:17 AM 8/11/2026 7:25 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 5883 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 8/12/2026 1:28:17 PM Approved

 09/01/2026TRAC:WALL BRACING SHEATHINGCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request9/1/2026 6:24:06 AM 9/1/2026 6:24 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 5883 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 9/1/2026 1:45:14 PM Approved Note Missing 2x2 square washers at garage portal frames

 09/28/2026TRAC:POST REARSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request9/24/2026 6:03:13 AM 9/24/2026 6:03 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 5883 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 9/28/2026 11:21:59 AM Porch post rear inspection approved

 09/28/2026TRAC:FIRE RESISTIVESHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request9/24/2026 6:02:24 AM 9/24/2026 6:02 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 5883 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 9/28/2026 11:22:01 AM Fire resistive inspection approved

 09/28/2026TRAC:WEATHER RESISTIVE BARRIERSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request9/24/2026 6:01:17 AM 9/24/2026 6:01 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 5883 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 9/28/2026 11:22:05 AM Weather resistive barrier inspection approved

 10/01/2026TRAC:REQUEST PRE ROUGH DOCBUILDING COUNTERNOT APPROVEDeTRAKiT Inspection Request9/30/2026 8:18:22 AM 9/30/2026 8:18 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 5883 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 10/1/2026 8:08:04 AM Need water & sewer; no burn report

 10/02/2026TRAC:REQUEST PRE ROUGH DOCBUILDING COUNTERAPPROVEDCB10/1/2026 8:43:55 AM 10/1/2026 8:43 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 5883 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com

 10/05/2026TRAC:ROUGH ELECTRICALVINCE RAPONENOT APPROVEDeTRAKiT Inspection Request10/2/2026 11:25:53 AM 10/2/2026 11:25 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 5883 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 10/5/2026 10:29:16 AM Wrong wire nuts at dining room switch and garage hallway switch at bedroom side. Rest of rough is good Reschedule

 10/05/2026TRAC:ROUGH FRAMEJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request10/2/2026 11:25:13 AM 10/2/2026 11:25 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 5883 RENBARGER ST Phone: 303709894 e-Mail: shoogeboom@tollbrothers.com 10/5/2026 12:32:18 PM NOT APPROVED- 1) COMPLETE RGH ELECTRICAL. 2) BOTTOM OF BCI FLOOR JOIST SPLIT/ NEED COALIFICATION FROM MANUFACTURING. 3) MISSING FIRE BLOCKING AT DOUBLE TOP PLATE/ SINGLE CAR GARAGE TOP OF STAIRS RIGHT. 4) MISSING FIRE BLOCKING AT DRILLED BOTTOM PLATE/ MAIN FLOOR BATHROOM OFF OF SINGLE CAR GARAGE. 5) OVER DRILLED/BORED EXTERIOR LOAD BEARING STUD FOR PLUMBING PENETRATION/ OFFICE LEFT ELEVATION. 6) MISSING FIRE BLOCKING AT PLUMBING DOUBLE TOP PLATE PENETRATION/ MAIN LEVEL HALL CLOSET LEFT ELEVATION. 7) DUCT UNSUPPORTED/ NOT CONNECTED / IN BASEMENT. 8) MISSING FLOOR DRAIN COVER / BASEMENT RIGHT ELEVATION. 9) BEAM POCKET INCOMPLETE/ BASEMENT REAR ELEVATION INSIDE CORNER. 10) DAMAGED BCI FLOOR JOIST DO TO ELECTRICAL PENETRATIONS GREATER THAN 2 INCHES. 11) UNFINISHED SLAB / IN BASEMENT AT WATER TREE. 12) MISSING CORRECT NUMBER OF LEDGER CONNECTIONS / BASEMENT STAIR LANDING. 13) MISSING CORRECT ATTACHMENTS AT STEEL POST BASE / UNDER BASEMENT STAIR LANDING. REST OF FRAME OK. NOTE: UNFINISHED BASEMENT/ REAR LID & PORCH.