| 07/01/2026 | TRAC:TEMPORARY CONSTRUCTION METER | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 6/30/2026 8:50:06 AM
6/30/2026 8:50 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5883 RENBARGER ST
Phone: 3037098942
e-Mail: shoogeboom@tollbrothers.com
7/1/2026 12:39:34 PM
Construction meter inspection approved
|
|
| 08/11/2026 | TRAC:GROUND PLUMBING | COLBY RIGGINS | CANCEL | eTRAKiT Inspection Request | 8/10/2026 9:44:06 AM
8/10/2026 9:44 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5883 RENBARGER ST
Phone: 3037098942
e-Mail: shoogeboom@tollbrothers.com
8/11/2026 7:29:20 AM
Canceled per superintendent Steve.
|
|
| 08/12/2026 | TRAC:GROUND PLUMBING | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 8/11/2026 7:25:17 AM
8/11/2026 7:25 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5883 RENBARGER ST
Phone: 3037098942
e-Mail: shoogeboom@tollbrothers.com
8/12/2026 1:28:17 PM
Approved
|
|
| 09/01/2026 | TRAC:WALL BRACING SHEATHING | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 9/1/2026 6:24:06 AM
9/1/2026 6:24 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5883 RENBARGER ST
Phone: 3037098942
e-Mail: shoogeboom@tollbrothers.com
9/1/2026 1:45:14 PM
Approved
Note
Missing 2x2 square washers at garage portal frames
|
|
| 09/28/2026 | TRAC:POST REAR | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 9/24/2026 6:03:13 AM
9/24/2026 6:03 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5883 RENBARGER ST
Phone: 3037098942
e-Mail: shoogeboom@tollbrothers.com
9/28/2026 11:21:59 AM
Porch post rear inspection approved
|
|
| 09/28/2026 | TRAC:FIRE RESISTIVE | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 9/24/2026 6:02:24 AM
9/24/2026 6:02 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5883 RENBARGER ST
Phone: 3037098942
e-Mail: shoogeboom@tollbrothers.com
9/28/2026 11:22:01 AM
Fire resistive inspection approved
|
|
| 09/28/2026 | TRAC:WEATHER RESISTIVE BARRIER | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 9/24/2026 6:01:17 AM
9/24/2026 6:01 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5883 RENBARGER ST
Phone: 3037098942
e-Mail: shoogeboom@tollbrothers.com
9/28/2026 11:22:05 AM
Weather resistive barrier inspection approved
|
|
| 10/01/2026 | TRAC:REQUEST PRE ROUGH DOC | BUILDING COUNTER | NOT APPROVED | eTRAKiT Inspection Request | 9/30/2026 8:18:22 AM
9/30/2026 8:18 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5883 RENBARGER ST
Phone: 3037098942
e-Mail: shoogeboom@tollbrothers.com
10/1/2026 8:08:04 AM
Need water & sewer; no burn report
|
|
| 10/02/2026 | TRAC:REQUEST PRE ROUGH DOC | BUILDING COUNTER | APPROVED | CB | 10/1/2026 8:43:55 AM
10/1/2026 8:43 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5883 RENBARGER ST
Phone: 3037098942
e-Mail: shoogeboom@tollbrothers.com
|
|
| 10/05/2026 | TRAC:ROUGH ELECTRICAL | VINCE RAPONE | NOT APPROVED | eTRAKiT Inspection Request | 10/2/2026 11:25:53 AM
10/2/2026 11:25 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5883 RENBARGER ST
Phone: 3037098942
e-Mail: shoogeboom@tollbrothers.com
10/5/2026 10:29:16 AM
Wrong wire nuts at dining room switch and garage hallway switch at bedroom side. Rest of rough is good
Reschedule
|
|
| 10/05/2026 | TRAC:ROUGH FRAME | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 10/2/2026 11:25:13 AM
10/2/2026 11:25 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5883 RENBARGER ST
Phone: 303709894
e-Mail: shoogeboom@tollbrothers.com
10/5/2026 12:32:18 PM
NOT APPROVED-
1) COMPLETE RGH ELECTRICAL.
2) BOTTOM OF BCI FLOOR JOIST SPLIT/ NEED COALIFICATION FROM MANUFACTURING.
3) MISSING FIRE BLOCKING AT DOUBLE TOP PLATE/ SINGLE CAR GARAGE TOP OF STAIRS RIGHT.
4) MISSING FIRE BLOCKING AT DRILLED BOTTOM PLATE/ MAIN FLOOR BATHROOM OFF OF SINGLE CAR GARAGE.
5) OVER DRILLED/BORED EXTERIOR LOAD BEARING STUD FOR PLUMBING PENETRATION/ OFFICE LEFT ELEVATION.
6) MISSING FIRE BLOCKING AT PLUMBING DOUBLE TOP PLATE PENETRATION/ MAIN LEVEL HALL CLOSET LEFT ELEVATION.
7) DUCT UNSUPPORTED/ NOT CONNECTED / IN BASEMENT.
8) MISSING FLOOR DRAIN COVER / BASEMENT RIGHT ELEVATION.
9) BEAM POCKET INCOMPLETE/ BASEMENT REAR ELEVATION INSIDE CORNER.
10) DAMAGED BCI FLOOR JOIST DO TO ELECTRICAL PENETRATIONS GREATER THAN 2 INCHES.
11) UNFINISHED SLAB / IN BASEMENT AT WATER TREE.
12) MISSING CORRECT NUMBER OF LEDGER CONNECTIONS / BASEMENT STAIR LANDING.
13) MISSING CORRECT ATTACHMENTS AT STEEL POST BASE / UNDER BASEMENT STAIR LANDING.
REST OF FRAME OK.
NOTE: UNFINISHED BASEMENT/ REAR LID & PORCH.
|
|