11/21/2026
10:44 PM
 
Permit No. 26-1826 Permit Type   RESIDENTIAL TRACT HOME Site Address   1603 DEHERDER DR
CASTLE ROCK, CO 80104
Applied   05/21/2026 Applicant   TOLL BROTHERS
Approved   06/05/2026 Owner   TOLL SOUTHWEST LLC C/O PROPERTY TAX DEPARTMENT
Issued   06/10/2026 Contractor  
Parent Permit No.   Description   NEW SINGLE FAMILY DETACHED RESIDENCE
  Notes   1603 Deherder
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 07/08/2026TRAC:TEMPORARY CONSTRUCTION METERSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request7/7/2026 2:27:40 PM 7/7/2026 2:27 PM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 7/8/2026 9:23:34 AM Temporary construction meter inspection approved 7/8/2026 9:26:28 AM Temporary construction meter inspection approved

 07/24/2026TRAC:GROUND PLUMBINGCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request7/23/2026 9:43:42 AM 7/23/2026 9:43 AM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 7/24/2026 9:46:09 AM Approved

 08/19/2026TRAC:WALL BRACING SHEATHINGSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request8/18/2026 12:39:40 PM 8/18/2026 12:39 PM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 8/19/2026 11:13:39 AM Wall brace sheathing inspection not approved 1. Over hanging soul plate at 3 car garage Reschedule inspection when corrections are completed OK to start weather barrier as repair will be visible after weather barriers installed

 09/23/2026TRAC:REQUEST PRE ROUGH DOCBUILDING COUNTERAPPROVEDCB9/22/2026 2:36:29 PM 9/22/2026 2:36 PM Nick Keane Calling wall brace again with first rough inspection Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com

 09/25/2026TRAC:WALL BRACING SHEATHINGSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request9/24/2026 10:43:32 AM 9/24/2026 10:43 AM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 9/25/2026 2:24:24 PM Wall bracing sheathing inspection not approved 1. Could not verify repair, as repair has been covered. provide engineer clarification when repair is uncovered to verify repair was done appropriately. Recall inspection when corrections are completed

 09/25/2026TRAC:ROUGH ELECTRICALSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request9/24/2026 10:43:33 AM 9/24/2026 10:43 AM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 9/25/2026 2:24:26 PM Rough electrical inspection, not approved 1. Both garages 6 risers, or more require a switch at top and bottom of stairs 2. Missing support to Romax within 12 inches of where Romax enters fireplace 3. Smoke detector second floor front left elevation not made up 4. Cold water bond needs to bond below the lowest shut off. Recall inspections when all corrections are completed Notes Verify radon fan cord as long enough to plug into receptacle provided

 09/25/2026TRAC:WEATHER RESISTIVE BARRIERMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request9/24/2026 10:43:33 AM 9/24/2026 10:43 AM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 9/25/2026 3:40:10 PM Wall bracing not approved.

 09/25/2026TRAC:ROUGH FRAMEMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request9/24/2026 10:43:33 AM 9/24/2026 10:43 AM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 9/25/2026 3:40:13 PM 1. Kitchen window not on plans. Wrong plans on site per Nick Keene. 2. Rough Electric not passed. Please have most updated plans on site. Inspected to general code compliance only. There are many notes from the home owner to move plumbing and electric. Please have everything moved that you are going and give us note in the inspection request, letting us know if something was moved prior to inspecting. Rough Plumbing ok Rough Mechanical ok Gas ok

 09/25/2026TRAC:POST REARMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request9/24/2026 10:43:32 AM 9/24/2026 10:43 AM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com

 09/25/2026TRAC:FIRE RESISTIVEMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request9/24/2026 10:43:32 AM 9/24/2026 10:43 AM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com

 09/29/2026TRAC:RE ROUGH ELECTRICALVINCE RAPONEAPPROVEDeTRAKiT Inspection Request9/28/2026 1:20:07 PM 9/28/2026 1:20 PM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 9/29/2026 12:21:11 PM No inspection card Rough electrical approved

 09/29/2026TRAC:RE ROUGH FRAMEMARTIN MAGERSINCOMPLETE-85FEEeTRAKiT Inspection Request9/28/2026 1:20:07 PM 9/28/2026 1:20 PM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 9/29/2026 12:40:47 PM Corrections not made 1. Kitchen window not on plans. Wrong plans on site per Nick Keene. 2. Rough Electric not passed. Please have most updated plans on site. Inspected to general code compliance only. There are many notes from the home owner to move plumbing and electric. Please have everything moved that you are going and give us note in the inspection request, letting us know if something was moved prior to inspecting.

 10/01/2026TRAC:WEATHER RESISTIVE BARRIERJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/30/2026 11:04:31 AM 9/30/2026 11:04 AM Nick Keane Engineer Letter in Attachments/Repair deemed good Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 10/1/2026 11:31:53 AM APPROVED.

 10/01/2026TRAC:WALL BRACING SHEATHINGJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/30/2026 11:04:30 AM 9/30/2026 11:04 AM Nick Keane Engineer Letter in Attachments/Repair deemed good Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 10/1/2026 11:31:57 AM APPROVED.

 10/01/2026TRAC:RE ROUGH FRAMEJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request9/30/2026 11:04:30 AM 9/30/2026 11:04 AM Nick Keane Engineer Letter in Attachments/Repair deemed good Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 10/1/2026 12:57:25 PM NOT- APPROVED- 1) MISSING FIRE-BLOCKING FOR DOUBLE TOP PLATE PENETRATION / RIGHT-SIDE OF ACCESS DOOR TO LIVABLE SPACE FROM SINGLE CAR GARAGE. 2) LOAD BEARING STUD BORED GREAT THAN 40% FOR LOAD BEARING EXTERIOR WALLS FOR PLUMBING HORIZONTAL PENETRATION THATS ALLOWED PER CODE FIGURE R602.6(1) 3) MISSING FIRE BLOCKING FOR UNUSED FLOOR PENETRATIONS/ IN MAIN LEVEL, LEFT REAR ELEVATION BATHROOM. 4) COMBUSTIBLE'S ON GREAT ROOM FIREPLACE. 5) MISSING FIRE BLOCKING AT REPAIRED CUTT BOTTOM PLATE / LEFT OF GREAT ROOM FIREPLACE. 6) MISSING FIRE BLOCKING AT UNUSED FLOOR PENETRATIONS/ MASTER BATHROOM SINKS. 7) MISSING FIRE BLOCKING AT UNUSED FLOOR PENETRATIONS/ UPSTAIRS BATHROOM, LEFT REAR ELEVATION. 8) MISSING FIRE BLOCKING / BASEMENT MID STAIR LANDING AT CONCEALED SPACE / FOUNDATION WALL , TOP OF WALL. REST OF FRAME - OK. RGH PLUMBING- OK. RGH MECHANICAL- OK. GAS ON TEST APPROVED ON INSPECTION 9/25/26. ISO- FURNACE GREAT ROOM FIREPLACE SECOND FURNACE DRYER REAR BBQ NOTE: UNFINISHED BASEMENT & CRAWLSPACE/ REAR LID & PORCH.

 10/02/2026TRAC:RE ROUGH FRAMEJOE CARBAUGHINCOMPLETE-85FEEeTRAKiT Inspection Request10/1/2026 2:54:56 PM 10/1/2026 2:54 PM Nick Keane Corrections completed Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 10/2/2026 12:43:36 PM NOT APPROVED- ITEM FROM PREVIOUS INSPECTION NOT CORRECTED- LOAD BEARING STUD BORED GREATER THAN 40% FOR LOAD BEARING EXTERIOR WALLS FOR PLUMBING HORIZONTAL PENETRATION THATS ALLOWED. R602.6 DRILLING AND NOTCHING OF STUDS # 2 OR EXCEPTION. "STUD SHOE".

 10/05/2026TRAC:RE ROUGH FRAMEJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request10/4/2026 10:26:19 PM 10/4/2026 10:26 PM Nick Keane Additional stud placed in exterior wall Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 10/5/2026 12:32:12 PM APPROVED.

 10/07/2026TRAC:INSULATIONSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request10/7/2026 5:42:11 AM 10/7/2026 5:42 AM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 10/7/2026 1:24:23 PM Insulation inspection approved

 10/14/2026TRAC:SHEAR WALL DRYWALLJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request10/12/2026 12:06:35 PM 10/12/2026 12:06 PM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 10/12/2026 12:41:53 PM 10/12/2026 12:41 PM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 10/14/2026 2:15:39 PM APPROVED.

 10/15/2026TRAC:LATH STONE BRICK TIEJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request10/14/2026 11:24:37 AM 10/14/2026 11:24 AM Nick Keane Contact Name: Nick Keane Site Address: 1603 DEHERDER DR Phone: 2816787538 e-Mail: nkeane@tollbrothers.com 10/15/2026 10:30:35 AM APPROVED.