| 07/08/2026 | TRAC:TEMPORARY CONSTRUCTION METER | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 7/7/2026 2:27:40 PM
7/7/2026 2:27 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
7/8/2026 9:23:34 AM
Temporary construction meter inspection approved
7/8/2026 9:26:28 AM
Temporary construction meter inspection approved
|
|
| 07/24/2026 | TRAC:GROUND PLUMBING | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 7/23/2026 9:43:42 AM
7/23/2026 9:43 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
7/24/2026 9:46:09 AM
Approved
|
|
| 08/19/2026 | TRAC:WALL BRACING SHEATHING | SHAWN VALENZUELA | NOT APPROVED | eTRAKiT Inspection Request | 8/18/2026 12:39:40 PM
8/18/2026 12:39 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
8/19/2026 11:13:39 AM
Wall brace sheathing inspection not approved
1. Over hanging soul plate at 3 car garage
Reschedule inspection when corrections are completed
OK to start weather barrier as repair will be visible after weather barriers installed
|
|
| 09/23/2026 | TRAC:REQUEST PRE ROUGH DOC | BUILDING COUNTER | APPROVED | CB | 9/22/2026 2:36:29 PM
9/22/2026 2:36 PM Nick Keane
Calling wall brace again with first rough inspection
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
|
|
| 09/25/2026 | TRAC:WALL BRACING SHEATHING | SHAWN VALENZUELA | NOT APPROVED | eTRAKiT Inspection Request | 9/24/2026 10:43:32 AM
9/24/2026 10:43 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
9/25/2026 2:24:24 PM
Wall bracing sheathing inspection not approved
1. Could not verify repair, as repair has been covered. provide engineer clarification when repair is uncovered to verify repair was done appropriately.
Recall inspection when corrections are completed
|
|
| 09/25/2026 | TRAC:ROUGH ELECTRICAL | SHAWN VALENZUELA | NOT APPROVED | eTRAKiT Inspection Request | 9/24/2026 10:43:33 AM
9/24/2026 10:43 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
9/25/2026 2:24:26 PM
Rough electrical inspection, not approved
1. Both garages 6 risers, or more require a switch at top and bottom of stairs
2. Missing support to Romax within 12 inches of where Romax enters fireplace
3. Smoke detector second floor front left elevation not made up
4. Cold water bond needs to bond below the lowest shut off.
Recall inspections when all corrections are completed
Notes
Verify radon fan cord as long enough to plug into receptacle provided
|
|
| 09/25/2026 | TRAC:WEATHER RESISTIVE BARRIER | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 9/24/2026 10:43:33 AM
9/24/2026 10:43 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
9/25/2026 3:40:10 PM
Wall bracing not approved.
|
|
| 09/25/2026 | TRAC:ROUGH FRAME | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 9/24/2026 10:43:33 AM
9/24/2026 10:43 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
9/25/2026 3:40:13 PM
1. Kitchen window not on plans. Wrong plans on site per Nick Keene.
2. Rough Electric not passed.
Please have most updated plans on site. Inspected to general code compliance only. There are many notes from the home owner to move plumbing and electric. Please have everything moved that you are going and give us note in the inspection request, letting us know if something was moved prior to inspecting.
Rough Plumbing ok
Rough Mechanical ok
Gas ok
|
|
| 09/25/2026 | TRAC:POST REAR | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 9/24/2026 10:43:32 AM
9/24/2026 10:43 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
|
|
| 09/25/2026 | TRAC:FIRE RESISTIVE | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 9/24/2026 10:43:32 AM
9/24/2026 10:43 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
|
|
| 09/29/2026 | TRAC:RE ROUGH ELECTRICAL | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 9/28/2026 1:20:07 PM
9/28/2026 1:20 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
9/29/2026 12:21:11 PM
No inspection card
Rough electrical approved
|
|
| 09/29/2026 | TRAC:RE ROUGH FRAME | MARTIN MAGERS | INCOMPLETE-85FEE | eTRAKiT Inspection Request | 9/28/2026 1:20:07 PM
9/28/2026 1:20 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
9/29/2026 12:40:47 PM
Corrections not made
1. Kitchen window not on plans. Wrong plans on site per Nick Keene.
2. Rough Electric not passed.
Please have most updated plans on site. Inspected to general code compliance only. There are many notes from the home owner to move plumbing and electric. Please have everything moved that you are going and give us note in the inspection request, letting us know if something was moved prior to inspecting.
|
|
| 10/01/2026 | TRAC:WEATHER RESISTIVE BARRIER | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 9/30/2026 11:04:31 AM
9/30/2026 11:04 AM Nick Keane
Engineer Letter in Attachments/Repair deemed good
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
10/1/2026 11:31:53 AM
APPROVED.
|
|
| 10/01/2026 | TRAC:WALL BRACING SHEATHING | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 9/30/2026 11:04:30 AM
9/30/2026 11:04 AM Nick Keane
Engineer Letter in Attachments/Repair deemed good
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
10/1/2026 11:31:57 AM
APPROVED.
|
|
| 10/01/2026 | TRAC:RE ROUGH FRAME | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 9/30/2026 11:04:30 AM
9/30/2026 11:04 AM Nick Keane
Engineer Letter in Attachments/Repair deemed good
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
10/1/2026 12:57:25 PM
NOT- APPROVED-
1) MISSING FIRE-BLOCKING FOR DOUBLE TOP PLATE PENETRATION / RIGHT-SIDE OF ACCESS DOOR TO LIVABLE SPACE FROM SINGLE CAR GARAGE.
2) LOAD BEARING STUD BORED GREAT THAN 40% FOR LOAD BEARING EXTERIOR WALLS FOR PLUMBING HORIZONTAL PENETRATION THATS ALLOWED
PER CODE FIGURE R602.6(1)
3) MISSING FIRE BLOCKING FOR UNUSED FLOOR PENETRATIONS/ IN MAIN LEVEL, LEFT REAR ELEVATION BATHROOM.
4) COMBUSTIBLE'S ON GREAT ROOM FIREPLACE.
5) MISSING FIRE BLOCKING AT REPAIRED CUTT BOTTOM PLATE / LEFT OF GREAT ROOM FIREPLACE.
6) MISSING FIRE BLOCKING AT UNUSED FLOOR PENETRATIONS/ MASTER BATHROOM SINKS.
7) MISSING FIRE BLOCKING AT UNUSED FLOOR PENETRATIONS/ UPSTAIRS BATHROOM, LEFT REAR ELEVATION.
8) MISSING FIRE BLOCKING / BASEMENT MID STAIR LANDING AT CONCEALED SPACE / FOUNDATION WALL , TOP OF WALL.
REST OF FRAME - OK.
RGH PLUMBING- OK.
RGH MECHANICAL- OK.
GAS ON TEST APPROVED ON INSPECTION 9/25/26.
ISO-
FURNACE
GREAT ROOM FIREPLACE
SECOND FURNACE
DRYER
REAR BBQ
NOTE: UNFINISHED BASEMENT & CRAWLSPACE/ REAR LID & PORCH.
|
|
| 10/02/2026 | TRAC:RE ROUGH FRAME | JOE CARBAUGH | INCOMPLETE-85FEE | eTRAKiT Inspection Request | 10/1/2026 2:54:56 PM
10/1/2026 2:54 PM Nick Keane
Corrections completed
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
10/2/2026 12:43:36 PM
NOT APPROVED-
ITEM FROM PREVIOUS INSPECTION NOT CORRECTED- LOAD BEARING STUD BORED GREATER THAN 40% FOR LOAD BEARING EXTERIOR WALLS FOR PLUMBING HORIZONTAL PENETRATION THATS ALLOWED. R602.6 DRILLING AND NOTCHING OF STUDS # 2 OR EXCEPTION. "STUD SHOE".
|
|
| 10/05/2026 | TRAC:RE ROUGH FRAME | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 10/4/2026 10:26:19 PM
10/4/2026 10:26 PM Nick Keane
Additional stud placed in exterior wall
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
10/5/2026 12:32:12 PM
APPROVED.
|
|
| 10/07/2026 | TRAC:INSULATION | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 10/7/2026 5:42:11 AM
10/7/2026 5:42 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
10/7/2026 1:24:23 PM
Insulation inspection approved
|
|
| 10/14/2026 | TRAC:SHEAR WALL DRYWALL | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 10/12/2026 12:06:35 PM
10/12/2026 12:06 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
10/12/2026 12:41:53 PM
10/12/2026 12:41 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
10/14/2026 2:15:39 PM
APPROVED.
|
|
| 10/15/2026 | TRAC:LATH STONE BRICK TIE | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 10/14/2026 11:24:37 AM
10/14/2026 11:24 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1603 DEHERDER DR
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
10/15/2026 10:30:35 AM
APPROVED.
|
|