| 06/18/2026 | TRAC:TEMPORARY CONSTRUCTION METER | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 6/17/2026 2:41:11 PM
6/17/2026 2:41 PM TOLL BROTHERS
PM inspection please
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
6/18/2026 11:37:17 AM
Temporary construction meter approved
|
|
| 07/10/2026 | TRAC:GROUND PLUMBING | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 7/8/2026 2:17:01 PM
7/8/2026 2:17 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
7/10/2026 11:20:39 AM
APPROVED.
NOTE: NO FOUNDATION, PLUMBING PENETRATIONS AT TIME OF GROUND PLUMB INSPECTION.
|
|
| 08/06/2026 | TRAC:ILC REVIEW | BUILDING COUNTER | NOT APPROVED | CB | 8/5/2026 11:30:18 AM
8/5/2026 11:30 AM TOLL BROTHERS
Is there no longer a grade cert review?
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
8/6/2026 8:17:06 AM
TOO EARLY FOR ILC REVIEW; NO ILC UPLAODED
|
|
| 08/06/2026 | TRAC:WALL BRACING SHEATHING | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 8/5/2026 11:21:33 AM
8/5/2026 11:21 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
8/6/2026 12:47:42 PM
Approved
|
|
| 08/17/2026 | TRAC:REQUEST PRE ROUGH DOC | JASON SMITH | APPROVED | eTRAKiT Inspection Request | 8/14/2026 10:11:08 AM
8/14/2026 10:11 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
|
|
| 09/02/2026 | TRAC:ROUGH FRAME | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 9/1/2026 10:34:38 AM
9/1/2026 10:34 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
9/2/2026 1:06:19 PM
NOT APPROVED.
1) MISSING BLOCKING BETWEEN TOP CORD EJ1 TRUSSES / S/ W REAR ELEVATION.
2) UNABLE TO VERIFY STEEL BEAMS BEARING DUE TO GROUT ALREADY IN PLACE AT RGH FRAME.
3) DRYING IN FROM THE OUTSIDE IN/ BASEMENT RIGHT ELEVATION.
4) COMPLETE RGH ELECTRICAL.
RGH PLUMBING- OK.
RGH MECHANICAL- OK.
GAS ON TEST - OK.
GAS ISO
FURNACE
RANGE
GREAT ROOM FIREPLACE
DRYER
NOTE: UNFINISHED WALK-OUT BASEMENT/ REAR LID & DECK.
|
|
| 09/02/2026 | TRAC:ROUGH DECK | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 9/1/2026 10:34:38 AM
9/1/2026 10:34 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
9/2/2026 1:06:21 PM
APPROVED.
|
|
| 09/02/2026 | TRAC:POST REAR | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 9/1/2026 10:34:37 AM
9/1/2026 10:34 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
9/2/2026 1:06:24 PM
APPROVED.
|
|
| 09/02/2026 | TRAC:WEATHER RESISTIVE BARRIER | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 9/1/2026 10:34:38 AM
9/1/2026 10:34 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
9/2/2026 1:25:12 PM
Weather resistant approved
|
|
| 09/02/2026 | TRAC:ROUGH ELECTRICAL | VINCE RAPONE | NOT APPROVED | eTRAKiT Inspection Request | 9/1/2026 10:34:38 AM
9/1/2026 10:34 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
9/2/2026 1:25:14 PM
Bond cold water
Add whip for low volt panel
Reschedule
|
|
| 09/02/2026 | TRAC:FIRE RESISTIVE | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 9/1/2026 10:34:37 AM
9/1/2026 10:34 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
9/2/2026 1:25:17 PM
Fire resistant approved
|
|
| 09/09/2026 | TRAC:RE ROUGH FRAME | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 9/8/2026 10:16:25 AM
9/8/2026 10:16 AM TOLL BROTHERS
Need to make we are are okay to move forward with the exception of the missing basement window. This is on order.
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
9/9/2026 11:29:11 AM
Rough frame approved
Rough electrical approved
|
|
| 09/15/2026 | TRAC:INSULATION | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 9/14/2026 9:19:03 AM
9/14/2026 9:19 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
9/15/2026 2:15:54 PM
APPROVED.
|
|
| 09/23/2026 | TRAC:LATH STONE BRICK TIE | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 9/22/2026 9:39:07 AM
9/22/2026 9:39 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: Cgetzinger@tollbrothers.com
9/23/2026 1:30:27 PM
APPROVED.
|
|
| 09/23/2026 | TRAC:SHEAR WALL DRYWALL | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 9/22/2026 8:06:12 AM
9/22/2026 8:06 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: Cgetzinger@tollbrothers.com
9/23/2026 1:30:30 PM
APPROVED.
|
|
| 10/08/2026 | D:REQ GRADE CERT REV | ADAN RIVAS | APPROVED | eTRAKiT Inspection Request | 10/7/2026 1:54:08 PM
10/7/2026 1:54 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
|
|
| 10/13/2026 | U: METER SET | GRANT TAYLOR | APPROVED | | |
|
| 10/29/2026 | D:FINAL DESC | JOHN GRAHN | APPROVED | eTRAKiT Inspection Request | 10/28/2026 9:17:44 AM
10/28/2026 9:17 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
|
|
| 11/04/2026 | U:HE TOILET | MICHAEL MURPHREE | APPROVED | eTRAKiT Inspection Request | 11/3/2026 1:58:47 PM
11/3/2026 1:58 PM TOLL SOUTHWEST SEE CR25-0649
3 toilets installed
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5539 VERVAIN TRL
Phone: 8123435401
e-Mail: cmay1@tollbrothers.com
11/4/2026 9:28:03 AM
Pass .8 gpf x 3
|
|
| 11/12/2026 | TRAC: FINAL DOC REVIEW | BUILDING COUNTER | APPROVED | CB | 11/11/2026 1:05:37 PM
11/11/2026 1:05 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
|
|
| 11/18/2026 | TRAC:FINAL ELECTRICAL | SHAWN VALENZUELA | NOT APPROVED | eTRAKiT Inspection Request | 11/17/2026 11:19:43 AM
11/17/2026 11:19 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
11/18/2026 12:24:21 PM
Final electrical inspection not approved
1. Dead front cover needs to be adjusted to avoid interfering with the top breaker handle.
2. Re-label panel schedule for surge protector and garage GFI is not legible
3. AC requires GFCI protection. AC unit capacity is between a 20 and 30 amp.
4. Unable to verify Ufer
5. Washer breaker at time of inspection is in the trip position. All breakers required to be on. Unable to test.
6. Keyless light in attic is damaged needs to be replaced
7. Single switched can light back deck not sealed properly.
Recall inspection when ready
|
|
| 11/18/2026 | TRAC:FINAL BUILDING | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 11/17/2026 11:19:43 AM
11/17/2026 11:19 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5539 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
11/18/2026 1:58:08 PM
NOT APPROVED-
1) OUTSIDE CORNER / S/W AT POST CAP &LID NOT SEALED.
2) MISSING FIRE BLOCKING / IN GARAGE FOR GARAGE DOOR OPENER LOW VOLT PENETRATIONS.
3) LOOSE ATTIC INSULATION NOT TO SPEC THICKNESS PER INSULATION CERTIFICATE.
4) COMPLETE FINAL ELECTRICAL.
REST OF FINAL - OK.
NOTE: UNFINISHED WALK-OUT BASEMENT/ REAR LID & DECK/ A/C INSTALLED.
|
|