  Date of Inspection Inspection Type Inspector Result Remarks Notes

 06/16/2026TRAC:TEMPORARY CONSTRUCTION METERSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request6/15/2026 11:36:51 AM 6/15/2026 11:36 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com 6/16/2026 11:02:45 AM Temporary construction meter not approved 1. No inspection card on site Recall inspection when corrections are completed

 06/18/2026TRAC:TEMPORARY CONSTRUCTION METERSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request6/17/2026 3:20:04 PM 6/17/2026 3:20 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com 6/18/2026 12:51:04 PM Temporary construction meter approved

 07/06/2026TRAC:GROUND PLUMBINGMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request7/6/2026 6:17:57 AM 7/6/2026 6:17 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@TOLLBROTHERS.COM

 07/30/2026TRAC:WALL BRACING SHEATHINGSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request7/29/2026 11:09:08 AM 7/29/2026 11:09 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com 7/30/2026 12:16:17 PM Wall brace and sheathing inspection not approved 1. 1 1/4 inch over hang soul plate at back left side of house. Need engineer clarification on overhanging soul plate Note OK to start Weather barrier at your own risk depending on engineer clarification repairs may have to be made Recall wall brace sheeting inspection when ready

 08/06/2026TRAC:WALL BRACING SHEATHINGSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/5/2026 10:12:40 AM 8/5/2026 10:12 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com 8/6/2026 1:49:04 PM Wall bracing inspection approved All corrections have been completed

 08/11/2026TRAC:REQUEST PRE ROUGH DOCBUILDING COUNTERAPPROVEDCB8/10/2026 12:09:32 PM 8/10/2026 12:09 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com

 08/19/2026TRAC:ROUGH FRAMEMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request8/18/2026 7:43:31 PM 8/18/2026 7:43 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@TOLLBROTHERS.COM 8/19/2026 11:15:05 AM 1. Missing 2x2 washers x 2 at each side of both portal frames at garage overhead doors. 2. Header at garage entry door requires 4 jack studs, only 1 installed. 3. Missing point load blocking, squash blocking under all 14 2 stud jack Stu's under living room. 4. Finish point load blocking, squash blocking;, under 8 stud post, 6 install, please fill missing areas to spread point load. At entry to living room. 5. All hot water pipes 3/4 in or larger must be insulated. Rough electric not passed at time of inspection Rough Mechanical ok Gas ok

 08/19/2026R:WEATHER RESISTIVE BARRIERMARTIN MAGERSAPPROVED

 08/19/2026TRAC:PRE ROCKMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request8/18/2026 7:43:31 PM 8/18/2026 7:43 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@TOLLBROTHERS.COM 8/19/2026 10:35:28 AM Inspector JOCA changed the inspection assignment from JOCA to MAM2

 08/19/2026TRAC:POST REARMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request8/18/2026 7:43:31 PM 8/18/2026 7:43 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@TOLLBROTHERS.COM 8/19/2026 10:35:54 AM Inspector JOCA changed the inspection assignment from JOCA to MAM2

 08/19/2026TRAC:PORCH POST FRONTMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request8/18/2026 7:43:31 PM 8/18/2026 7:43 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@TOLLBROTHERS.COM 8/19/2026 10:36:14 AM Inspector JOCA changed the inspection assignment from JOCA to MAM2

 08/19/2026TRAC:ROUGH ELECTRICALSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request8/18/2026 7:43:31 PM 8/18/2026 7:43 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@TOLLBROTHERS.COM 8/19/2026 12:46:03 PM Rough electrical inspection, not approved 1. Secondaries entering meter housing are loose check all 2. Wire is not landed into fireplace first floor Recall rough electrical inspection when all corrections are completed Second floor, furnace, and basement furnace not time of inspection

 08/19/2026TRAC:FIRE RESISTIVESHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/18/2026 7:43:30 PM 8/18/2026 7:43 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@TOLLBROTHERS.COM 8/19/2026 12:46:07 PM Fire resistive inspection approved

 08/20/2026TRAC:RE ROUGH FRAMESHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/19/2026 2:45:44 PM 8/19/2026 2:45 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com 8/20/2026 1:20:39 PM Rough frame inspection approved Electrical, plumbing, mechanical approved

 08/26/2026TRAC:INSULATIONSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/25/2026 3:29:58 PM 8/25/2026 3:29 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@TOLLBROTHERS.COM 8/26/2026 7:25:42 AM Inspector JOCA changed the inspection assignment from JOCA to SHVA 8/26/2026 10:44:21 AM Insulation inspection approved

 09/02/2026TRAC:SHEAR WALL DRYWALLSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request9/1/2026 1:40:23 PM 9/1/2026 1:40 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com 9/2/2026 2:54:05 PM Shear wall drywall inspection approved

 09/17/2026TRAC:LATH STONE BRICK TIEJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/16/2026 12:55:03 PM 9/16/2026 12:55 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com 9/17/2026 1:23:08 PM APPROVED.

 10/14/2026D:REQ GRADE CERT REVJOHN GRAHNAPPROVEDeTRAKiT Inspection Request10/13/2026 1:35:08 PM 10/13/2026 1:35 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com

 10/14/2026TRAC:ILC REVIEWBUILDING COUNTERAPPROVEDeTRAKiT Inspection Request10/13/2026 1:35:09 PM 10/13/2026 1:35 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com

 10/14/2026D:FINAL DESCADAN RIVASAPPROVEDeTRAKiT Inspection Request10/13/2026 1:35:40 PM 10/13/2026 1:35 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com 10/14/2026 4:07:30 PM Remove stockpile in the tract behind this address.

 10/20/2026TRAC:SHOWER PANSHAWN VALENZUELACANCELeTRAKiT Inspection Request10/19/2026 1:20:06 PM 10/19/2026 1:20 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com 10/20/2026 10:11:33 AM Requested to cancel inspection per contractor a shower pan inspection is not required underneath this permit

 10/21/2026U: METER SETGRANT TAYLORAPPROVED

 10/23/2026U:HE TOILETWILLIAM BROWNAPPROVED

TRAC:FINAL BUILDINGTRACT INSPECTOR BeTRAKiT Inspection Request10/26/2026 11:00:04 AM 10/26/2026 11:00 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com

 10/26/2026TRAC: FINAL DOC REVIEWBUILDING COUNTERAPPROVEDCB10/25/2026 9:31:01 PM 10/25/2026 9:31 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@TOLLBROTHERS.COM

TRAC:FINAL ELECTRICALTRACT INSPECTOR BeTRAKiT Inspection Request10/26/2026 11:00:04 AM 10/26/2026 11:00 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com

 10/28/2026TRAC:FINAL BUILDINGSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request10/27/2026 12:58:51 PM 10/27/2026 12:58 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@tollbrothers.com 10/28/2026 1:58:58 PM Final building inspection not approved 1. Kitchen hood not installed that time of inspection unable to test 2. Electric oven not installed at that time of inspection 3. Recirculating, hot water line requires all hot water lines to be insulated 4. Install shut off at bottom of hot water heater for recirculating line 5. ICC label missing at basement furnace 6. Damper for make up air for hood incomplete in basement 7. Could not verify gas shut off for fireplace on first floor 8. Can not verify that master bathroom shower glass is provided with safety glazing on two small end panels 9. Drywall needs to be patched on second floor, mechanical furnace room 10. ICC label missing at second floor furnace 11. Water tree in basement leaking 12. Water heater exhaust needs to be 3 feet away from operable window 13. At next inspection have all drywall patches complete. 14. Insulation in attic by radon fan has been pushed down. Recall inspection when all corrections are complete completed Electrical approved

 10/30/2026TRAC:RE FINAL BUILDINGSHAWN VALENZUELAAPPROVED FOR COeTRAKiT Inspection Request10/29/2026 6:45:27 PM 10/29/2026 6:45 PM TOLL SOUTHWEST SEE CR25-0649 - Cook top is installed and functional - Gas shut of is internal, front grate will be removed for inspection - Glass is tempered with stamp in bottom right corner Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 818 DUNLAP RD Phone: 7204802834 e-Mail: phart@TOLLBROTHERS.COM 10/30/2026 1:27:06 PM Final building inspection approved All corrections have been completed Electrical, plumbing, mechanical approved