| 06/18/2026 | TRAC:TEMPORARY CONSTRUCTION METER | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 6/17/2026 2:40:16 PM
6/17/2026 2:40 PM TOLL BROTHERS
PM inspection please
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
6/18/2026 11:45:18 AM
Temporary construction meter approved
|
|
| 07/09/2026 | TRAC:GROUND PLUMBING | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 7/8/2026 11:55:11 AM
7/8/2026 11:55 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
7/9/2026 1:38:20 PM
APPROVED.
|
|
| 07/20/2026 | TRAINING_JOE | JOE CARBAUGH | APPROVED | | 7/20/2026 2:33:28 PM
TRAINING.
|
|
| 08/04/2026 | TRAC:WALL BRACING SHEATHING | COLBY RIGGINS | NOT APPROVED | eTRAKiT Inspection Request | 8/3/2026 1:08:44 PM
8/3/2026 1:08 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
8/4/2026 2:26:44 PM
1. Garage rear wall call for 3in edge nailing
2. Single car garage exterior is missing two rows of vertical nailing
|
|
| 08/06/2026 | TRAC:WALL BRACING SHEATHING | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 8/5/2026 11:20:33 AM
8/5/2026 11:20 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
8/6/2026 12:47:39 PM
Approved
|
|
| TRAC:REQUEST PRE ROUGH DOC | BUILDING COUNTER | | VOIDED (CB 8/13/2026) | 8/13/2026 1:34:05 PM
8/13/2026 1:34 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
8/13/2026 4:20:36 PM
Inspection voided by CB. Most recent remarks follow: eTRAKiT Inspection Request
|
|
| TRAC:RE ROUGH ELECTRICAL | VINCE RAPONE | | eTRAKiT Inspection Request | 8/18/2026 3:22:30 PM
8/18/2026 3:22 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
|
|
| 08/14/2026 | TRAC:REQUEST PRE ROUGH DOC | BUILDING COUNTER | APPROVED | eTRAKiT Inspection Request | 8/13/2026 1:31:19 PM
8/13/2026 1:31 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
|
|
| TRAC:POST REAR | MICHAEL RANKIN | | eTRAKiT Inspection Request | 8/18/2026 3:22:30 PM
8/18/2026 3:22 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
|
|
| TRAC:RE ROUGH FRAME | MICHAEL RANKIN | | eTRAKiT Inspection Request | 8/18/2026 3:22:30 PM
8/18/2026 3:22 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
|
|
| TRAC:FIRE RESISTIVE | MICHAEL RANKIN | | eTRAKiT Inspection Request | 8/18/2026 3:22:30 PM
8/18/2026 3:22 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
|
|
| TRAC:WEATHER RESISTIVE BARRIER | MICHAEL RANKIN | | eTRAKiT Inspection Request | 8/18/2026 3:22:30 PM
8/18/2026 3:22 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
|
|
| 08/21/2026 | TRAC:WEATHER RESISTIVE BARRIER | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 8/19/2026 1:55:00 PM
8/19/2026 1:54 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
8/21/2026 1:21:25 PM
Weather resistive barrier inspection approved
|
|
| 08/21/2026 | TRAC:ROUGH ELECTRICAL | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 8/19/2026 1:54:59 PM
8/19/2026 1:54 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
8/21/2026 1:21:30 PM
Rough electrical inspection approved
Note
Cold water, bond, incomplete at time of inspection will verify it final
|
|
| 08/21/2026 | TRAC:FIRE RESISTIVE | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 8/19/2026 1:54:59 PM
8/19/2026 1:54 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
8/21/2026 1:21:33 PM
Fire resistive inspection approved
|
|
| 08/21/2026 | TRAC:ROUGH FRAME | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 8/19/2026 1:54:59 PM
8/19/2026 1:54 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
8/21/2026 3:07:34 PM
NOT APPROVED-
1) WATER NOT ON TEST.
2) DRAIN FOR FURNACE TO FLOOR DRAIN TO BE SUPPORTED BY FINAL.
3) MISSING FIRE BLOCKING FOR ELECTRICAL FLOOR PENETRATIONS/ IN BASEMENT N/ E CORNER.
4) TWO CAR GARAGE PORTAL FRAME MISSING 2x2x3/16" WASHERS PER APA PORTAL FRAME DETAIL FR-165
5) COMPLETE RGH ELECTRICAL.
6) MISSING MECHANICAL CONNECTIONS AT POST CAP FOR REAR LID.
REST OF FRAME - OK.
RGH MECHANICAL- OK.
RGH PLUMBING-NOT APPROVED.
GAS ON TEST - OK.
ISO-
FURNACE
WATER HEATER
GREAT ROOM FIREPLACE
DRYER
RANGE
REAR OPT PATIO
NOTE: CRAWLSPACE & UNFINISHED BASEMENT/ REAR LID & PORCH.
|
|
| 08/21/2026 | TRAC:POST REAR | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 8/19/2026 1:54:59 PM
8/19/2026 1:54 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
8/21/2026 3:07:37 PM
NOT APPROVED-
1) MISSING REAR LID POST CAP MECHANICAL CONNECTIONS.
2) POST BASE CONNECTIONS- OK.
|
|
| 08/25/2026 | TRAC:RE ROUGH FRAME | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 8/24/2026 10:50:52 AM
8/24/2026 10:50 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
8/25/2026 1:10:42 PM
Rough frame inspection approved
Electrical plumbing, mechanical approved
|
|
| 08/25/2026 | TRAC:POST REAR | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 8/24/2026 10:50:52 AM
8/24/2026 10:50 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
8/25/2026 1:10:46 PM
Rear porch post inspection approved
|
|
| 09/01/2026 | TRAC:INSULATION | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 8/31/2026 2:59:46 PM
8/31/2026 2:59 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
9/1/2026 11:21:52 AM
Insulation approved
|
|
| 09/08/2026 | TRAC:SHEAR WALL DRYWALL | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 9/7/2026 8:45:30 PM
9/7/2026 8:45 PM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: Cgetzinger@tollbrothers.com
9/8/2026 1:30:33 PM
APPROVED.
|
|
| 09/29/2026 | REQ REPLACEMENT INSP CARD | BUILDING COUNTER | APPROVED | | 9/28/2026 10:42:45 AM
called in by Carrie. cant add to etrakit anymore
|
|
| 09/29/2026 | TRAC:LATH STONE BRICK TIE | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 9/28/2026 10:34:51 AM
9/28/2026 10:34 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: Cgetzinger@tollbrothers.com
9/29/2026 12:21:09 PM
No inspection card
Lath approved
|
|
| 10/13/2026 | U: METER SET | GRANT TAYLOR | METER INSP FAIL 1 | | 10/13/2026 1:07:25 PM
A $50.00 re-inspection fee will be charged to the building permit. Once corrections have been made, please email your request for a re-inspection to meterset@crgov.com. Please note that we have up to four business days from the initial request to complete the re-inspection.
Can't have a plastic PRV, must be brass.
|
|
| 10/21/2026 | U: METER SET | GRANT TAYLOR | APPROVED | | |
|
| 10/29/2026 | D:REQ GRADE CERT REV | JOHN GRAHN | APPROVED | eTRAKiT Inspection Request | 10/28/2026 12:33:41 PM
10/28/2026 12:33 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7203523051
e-Mail: cgetzinger@TOLLBROTHERS.COM
|
|
| 11/04/2026 | U:HE TOILET | MICHAEL MURPHREE | APPROVED | eTRAKiT Inspection Request | 11/3/2026 9:51:02 AM
11/3/2026 9:51 AM TOLL SOUTHWEST SEE CR25-0649
Contact Name: TOLL SOUTHWEST SEE CR25-0649
Site Address: 5675 VERVAIN TRL
Phone: 8123435401
e-Mail: cmay1@tollbrothers.com
11/4/2026 9:28:00 AM
Pass .8 gpf x 3
|
|
| 11/12/2026 | D:FINAL DESC | LUKE HALVORSON | APPROVED | eTRAKiT Inspection Request | 11/11/2026 1:07:06 PM
11/11/2026 1:07 PM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
|
|
| 11/16/2026 | TRAC: FINAL DOC REVIEW | BUILDING COUNTER | APPROVED | cb | 11/13/2026 9:33:23 AM
11/13/2026 9:33 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
|
|
| 11/18/2026 | TRAC:FINAL ELECTRICAL | SHAWN VALENZUELA | NOT APPROVED | eTRAKiT Inspection Request | 11/17/2026 11:19:04 AM
11/17/2026 11:19 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
11/18/2026 1:34:02 PM
Final electrical inspection not approved
1. Missing inner system bond
2. AC requires GFCI protection
3. Dead front cover, not sitting flush to breakers dead front interfering with bath GFI breaker handle
4. All exterior receptacles have no power
5. Rear patio receptacle, bubble cover will not closing properly
6. Rear patio can light exterior lid, not sealed properly
7. Basement GFI receptacle will not reset
Recall inspection when ready
|
|
| 11/18/2026 | TRAC:FINAL BUILDING | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 11/17/2026 11:19:04 AM
11/17/2026 11:19 AM TOLL BROTHERS
Contact Name: TOLL BROTHERS
Site Address: 5675 VERVAIN TRL
Phone: 7204418128
e-Mail: cgetzinger@TOLLBROTHERS.COM
11/18/2026 1:39:30 PM
NOT APPROVED-
1) MISSING FALL PROTECTION FOR 30" AND HIGHER AT LEFT REAR ELEVATION WITH IN 3' OF A DESIGNATED WALKING PATH.
2) MISSING GFCI PER NEC210.8 (f)
3) CAN LIGHT NOT FULLY RECESSED / REAR PORCH LID COVER.
4) COMPLETE FINAL ELECTRICAL.
REST OF FINAL - OK.
NOTE: DAMAGED FLOOR SHEATHING/ IN BASEMENT REAR RIGHT ELEVATION.
CRAWLSPACE/ UNFINISHED BASEMENT/ REAR LID & PORCH/ A/C INSTALLED.
|
|