11/21/2026
10:43 PM
 
Permit No. 26-1702 Permit Type   RESIDENTIAL TRACT HOME Site Address   266 ALUMROOT ST
CASTLE ROCK, CO 80104
Applied   05/12/2026 Applicant   TOLL BROTHERS
Approved   07/17/2026 Owner   TOLL SOUTHWEST LLC C/O PROPERTY TAX DEPARTMENT
Issued   07/21/2026 Contractor  
Parent Permit No.   Description   NEW SINGLE FAMILY DETACHED RESIDENCE CUSTOM HOME - MODEL
  Notes   Not a master permit home applying under 2018 codes
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 07/22/2026TRAC:TEMPORARY CONSTRUCTION METERVINCE RAPONEAPPROVEDeTRAKiT Inspection Request7/21/2026 11:35:29 AM 7/21/2026 11:35 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM 7/22/2026 10:59:18 AM Temp meter approved Okay to release meter

 07/27/2026TRAC:GROUND PLUMBINGJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request7/23/2026 12:18:32 PM 7/23/2026 12:18 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM 7/27/2026 11:43:12 AM APPROVED.

 08/11/2026TRAC:WALL BRACING SHEATHINGSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/10/2026 8:29:03 AM 8/10/2026 8:29 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 8/11/2026 1:41:40 PM Wall brace inspection approved

 08/19/2026TRAC:WEATHER RESISTIVE BARRIERVINCE RAPONEAPPROVEDeTRAKiT Inspection Request8/18/2026 9:29:38 AM 8/18/2026 9:29 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM 8/19/2026 10:01:20 AM Weather barrier approved

 08/19/2026TRAC:FIRE RESISTIVEVINCE RAPONEAPPROVEDeTRAKiT Inspection Request8/18/2026 9:29:38 AM 8/18/2026 9:29 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM 8/19/2026 10:01:23 AM Fire resistant approved

 08/24/2026TRAC:POST REARSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/21/2026 10:05:49 AM 8/21/2026 10:05 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 8/24/2026 10:28:28 AM Rear porch post inspection approved

 09/10/2026TRAC:REQUEST PRE ROUGH DOCBUILDING COUNTERAPPROVEDCB9/9/2026 12:44:08 PM 9/9/2026 12:44 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM

 09/11/2026TRAC:ROUGH ELECTRICALSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request9/9/2026 12:12:05 PM 9/9/2026 12:12 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 9/11/2026 11:44:54 AM Rough electrical inspection approved

 09/11/2026TRAC:ROUGH FRAMEJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/9/2026 12:12:04 PM 9/9/2026 12:12 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 9/11/2026 12:37:12 PM APPROVED- RGH PLUMBING- APPROVED. RGH MECHANICAL- APPROVED. GAS ON TEST - OK. ISO FURNACE GREAT ROOM FIREPLACE DRYER RANGE TANKLESS WATER HEATER BBQ NOTE: UNFINISHED BASEMENT/ REAR LID & PORCH.

 09/15/2026TRAC:INSULATIONJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/14/2026 10:36:23 AM 9/14/2026 10:36 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM 9/15/2026 12:32:42 PM APPROVED.

D:REQ BOND REVIEWKIM GUITEVOIDED (KIGU 9/17/2026)9/17/2026 10:41:24 AM Inspection voided by KIGU. Most recent remarks follow: SEE SUBPERMIT SP26-0242

 09/21/2026TRAC:SHEAR WALL DRYWALLJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/18/2026 8:56:36 AM 9/18/2026 8:56 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM 9/21/2026 10:05:49 AM APPROVED.

 09/21/2026U: METER SETGRANT TAYLORAPPROVED

 09/24/2026D:REQ GRADE CERT REVJOHN GRAHNAPPROVEDVOIDED (KIGU 9/29/2026)9/23/2026 8:13:13 AM 9/23/2026 8:13 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM 9/29/2026 4:35:40 PM Inspection voided by KIGU. Most recent remarks follow: Model home

 10/01/2026TRAC:SHOWER PANJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/30/2026 10:40:55 AM 9/30/2026 10:40 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 10/1/2026 11:31:50 AM APPROVED- CUSTOM SHOWER PAN IS IN CONFORMANCE WITH THE IRC / P 2708 THROUGH P 2709.4.1

 09/30/2026TRAC:SHOWER PANMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request9/29/2026 9:32:26 AM 9/29/2026 9:32 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM 10/1/2026 2:47:03 PM Master shower approved, Hall bath shower incomplete.

 10/13/2026D:REQ GRADE CERT REVJOHN GRAHNCANCELSee Sub Permit SP26-024210/12/2026 12:09:09 PM 10/12/2026 12:09 PM TOLL BROTHERS Model home. Driveway bonds are in place. Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 10/13/2026 12:42:21 PM Model home with missing driveway see sub permit SP26-0242 10/13/2026 12:59:19 PM No need to call in another GC review as this is covered under the sub-permit because you bonded this. Please get a hold of the Town Bond Request Form for instructions. See the September review to direct you to the sub permit.

 10/26/2026U:HE TOILETWILLIAM BROWNAPPROVED

 11/05/2026TRAC:FINAL BUILDINGJOE CARBAUGHNOT APPROVEDStock furniture only11/5/2026 1:24:20 PM NOT APPROVED- BUILDING FINAL LIFE SAFETY INSPECTION ONLY. 1) MISSING FALL PROTECTION FOR 30" OR GREATER/ FRONT ENTRANCE. 2) MISSING CODE COMPLIANT GUARD FOR 30" OR GREATER ON / RIGHT ELEVATION OF REAR PORCH. 3) MISSING CODE COMPLIANT HAND RAIL FOR BASEMENT STAIRS. 4) RE- SCHEDULE BUILDING LIFE SAFETY FINAL WHEN ITEMS HAVE BEEN CORRECTED.

 11/05/2026TRAC:FINAL ELECTRICALSHAWN VALENZUELANOT APPROVEDStock furniture only11/5/2026 2:20:14 PM Final electrical inspection not approved 1. Support pvc entering meter housing 2. Missing inter system bond 3. Bedroom 2 breaker will not reset 4. Ac requires gfci protection breaker is over sized ac unit calls for 17.3 minimum of 30 maximum 40 installed 5. Emergency disconnect sticker missing 6. Exterior light east side above electrical panel missing 7. Front stair lighting incomplete 8. Front bedroom all receptacle have no power 9. Clothes washer missing receptacle cover plate and spark ring 10. Dryer receptacle missing plate and spark ring 11. Laundry room exhaust fan is tripping circuit when in high speed 12. Tape light unfinished in primary closet 13. No ladder to verify attic 14. Primary bathroom missing vanity lights not installed Recall inspection when corrections are completed Notes Garage inspection not completed at this time. Due to garage is now sales office Ok to stock furniture except front bedroom due to all receptacles not working. Pending final building

 11/12/2026TRAC: FINAL DOC REVIEWBUILDING COUNTERAPPROVEDCB11/10/2026 6:26:16 PM 11/10/2026 6:26 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM

 11/16/2026TRAC:FINAL ELECTRICALSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request11/12/2026 1:14:57 PM 11/12/2026 1:14 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 11/16/2026 11:30:07 AM Final electrical inspection approved All corrections have been completed

 11/16/2026TRAC:FINAL BUILDINGJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request11/12/2026 1:14:57 PM 11/12/2026 1:14 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 266 ALUMROOT ST Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 11/16/2026 1:51:22 PM NOT APPROVED- 1) FINAL BUILDING OK PENDING SIGNATURE FROM FIRE DEPT. NOTE: MISSING HARDWARE FOR INTERIOR GLASS DOORS, PASSED BECAUSE THEY SWING BOTH DIRECTIONS.