Permit No. 26-1572 Permit Type   RESIDENTIAL TRACT HOME Site Address   5525 VERVAIN TRL
CASTLE ROCK, CO 80104
Applied   05/04/2026 Applicant   TOLL BROTHERS
Approved   05/20/2026 Owner   TOLL BROTHERS
Issued   05/27/2026 Contractor  
Parent Permit No.   Description   NEW SINGLE FAMILY DETACHED RESIDENCE W/ CUSTOM TRUSSES
  Notes   5525 Vervain
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 05/29/2026TRAC:TEMPORARY CONSTRUCTION METERSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request5/28/2026 11:13:43 AM 5/28/2026 11:13 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM 5/29/2026 12:28:54 PM Temp construction meter inspection approved

 06/17/2026TRAC:GROUND PLUMBINGJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request6/16/2026 1:06:02 PM 6/16/2026 1:06 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM 6/17/2026 2:55:20 PM APPROVED.

 07/10/2026TRAC:WALL BRACING SHEATHINGJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request7/8/2026 12:06:31 PM 7/8/2026 12:06 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 7/10/2026 11:20:35 AM APPROVED.

 07/22/2026TRAC:REQUEST PRE ROUGH DOCBUILDING COUNTERAPPROVEDeTRAKiT Inspection Request7/21/2026 11:02:20 AM 7/21/2026 11:02 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM

 07/22/2026TRAC:FIRE RESISTIVESHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request7/21/2026 10:46:22 AM 7/21/2026 10:46 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 7/22/2026 1:37:19 PM Fire assistive inspection approved Note No fire protection is required on exterior eaves. No burn spray has been installed in basement.

 07/22/2026TRAC:POST REARSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request7/21/2026 10:42:24 AM 7/21/2026 10:42 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 7/22/2026 1:37:21 PM Porch post rear inspection approved

 07/22/2026TRAC:PORCH POST FRONTSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request7/21/2026 10:42:24 AM 7/21/2026 10:42 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 7/22/2026 1:37:23 PM Porch post front inspection approved

 07/22/2026TRAC:ROUGH DECKSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request7/21/2026 10:47:27 AM 7/21/2026 10:47 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 7/22/2026 2:25:20 PM Rough deck inspection approved Lid of deck has not been inspected at this time

 07/22/2026TRAC:WEATHER RESISTIVE BARRIERSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request7/21/2026 10:46:23 AM 7/21/2026 10:46 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 7/23/2026 2:29:11 PM Weather barrier inspection not approved 1. Above 2 car garage exposed plywood 2. Weather barrier cut short on single car garage north bottom 3. Pluming stub out missing flashing on north side 4. Exposed plywood basement windows x2 5. Weather barrier cut short south side of house 6. Multiple rips and tears on south side of house 7. missing stub out for all electrical/ flashing 8. missing back sliding glass door Please recall inspection when corrections are completed ok to release water meter

 07/31/2026TRAC:WEATHER RESISTIVE BARRIERJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request7/30/2026 7:09:53 AM 7/30/2026 7:09 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 7/31/2026 10:19:43 AM APPROVED.

 08/12/2026TRAC:ROUGH ELECTRICALSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request8/10/2026 9:14:54 AM 8/10/2026 9:14 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 8/12/2026 11:09:32 AM Rough electrical inspection not approved 1. Flex in garage for future solar not fully set into flex connector. 2. Lights in cover deck lid incomplete missing light brackets. 3. Coiled romex in basement in front of slider incomplete. Recall rough electrical inspection when corrections are completed

 08/12/2026TRAC:ROUGH FRAMECOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request8/10/2026 9:14:54 AM 8/10/2026 9:14 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 8/12/2026 1:28:14 PM 1. Missing 3 2x6 at double ply girder at two car garage. 2. Double ply girder the trusses are not fully seated in the hangers 3. Missing gable end bracing above two car garage 4. Front porch trusses missing side nailing 5. Remove combustibles off the fireplace 6. Need an fha plate at the dryer duct at the bearing wall 7. No gas iso onsite 8. Trusses A5 web 4 to 18 is missing lateral bracing Water ok Dwv ok Need gas

 08/13/2026TRAC:LATH STONE BRICK TIEJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request8/12/2026 7:55:11 AM 8/12/2026 7:55 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 8/13/2026 1:45:22 PM NOT APPROVED- 1) MISSING METAL LATH AT TIME OF INSPECTION. 2) RE-CALL WHEN READY.

 08/14/2026TRAC:RE ROUGH ELECTRICALVINCE RAPONEAPPROVEDeTRAKiT Inspection Request8/12/2026 11:56:27 AM 8/12/2026 11:56 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 8/14/2026 10:02:11 AM Rough electrical approved

 08/14/2026TRAC:RE ROUGH FRAMECOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request8/12/2026 11:56:27 AM 8/12/2026 11:56 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 8/14/2026 2:07:44 PM 4. Front porch trusses missing side nailing, cannot verify because lid is covered now 5. Remove combustibles off the fireplace 6. Need an fha plate at the dryer duct at the bearing wall Water ok Dwv ok gas ok Gas appliances installed furnace, water heater, fireplace, range

 08/17/2026TRAC:RE ROUGH FRAMECOLBY RIGGINSINCOMPLETE-85FEEeTRAKiT Inspection Request8/14/2026 11:32:13 AM 8/14/2026 11:32 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 8/17/2026 10:48:10 AM 4. Front porch trusses missing side nailing, cannot verify because lid is covered now 5. Remove combustibles off the fireplace Water ok Dwv ok gas ok Gas appliances installed furnace, water heater, fireplace, range

 08/19/2026TRAC:LATH STONE BRICK TIEBRETT LONGNECKERAPPROVEDeTRAKiT Inspection Request8/18/2026 6:29:09 AM 8/18/2026 6:29 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: SCOOLEY@TOLLBROTHERS.COM

 08/19/2026TRAC:RE ROUGH FRAMEBRETT LONGNECKERAPPROVEDeTRAKiT Inspection Request8/18/2026 6:28:26 AM 8/18/2026 6:28 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM

 08/25/2026TRAC:INSULATIONSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request8/24/2026 7:48:20 AM 8/24/2026 7:48 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 8/25/2026 12:45:59 PM Insulation inspection approved

 08/28/2026TRAC:SHEAR WALL DRYWALLJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request8/27/2026 3:15:56 PM 8/27/2026 3:15 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 8/28/2026 12:23:25 PM APPROVED

TRAC:ILC REVIEWBUILDING COUNTEReTRAKiT Inspection Request9/15/2026 1:44:08 PM 9/15/2026 1:44 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM

 09/16/2026D:REQ GRADE CERT REVJOHN GRAHNAPPROVED

 09/22/2026U: METER SETGRANT TAYLORMETER INSP FAIL 19/22/2026 11:31:17 AM A $50.00 re-inspection fee will be charged to the building permit. Once corrections have been made, please email your request for a re-inspection to meterset@crgov.com. Please note that we have up to four business days from the initial request to complete the re-inspection. Meter tree leaking

 10/05/2026U: METER SETGRANT TAYLORMETER INSP FAIL 210/5/2026 1:49:27 PM A $50.00 re-inspection fee will be charged to the building permit. Once corrections have been made, please email your request for a re-inspection to meterset@crgov.com. Please note that we have up to four business days from the initial request to complete the re-inspection. Curbstop needs to be visible and accessible upon arrival

 10/09/2026U: METER SETGRANT TAYLORMETER INSP FAIL 310/9/2026 11:28:56 AM A $50.00 re-inspection fee will be charged to the building permit. Once corrections have been made, please email your request for a re-inspection to meterset@crgov.com. Please note that we have up to four business days from the initial request to complete the re-inspection. Need to have TOCR placard in the garage.

 10/13/2026U: METER SETGRANT TAYLORAPPROVED

 10/13/2026D:FINAL DESCJOHN GRAHNAPPROVEDeTRAKiT Inspection Request10/12/2026 8:43:20 AM 10/12/2026 8:43 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 10/13/2026 3:33:04 PM Front and backyard are fully landscaped.

 10/21/2026U:HE TOILETWILLIAM BROWNAPPROVED

 10/27/2026TRAC: FINAL DOC REVIEWBUILDING COUNTERAPPROVEDeTRAKiT Inspection Request10/26/2026 2:52:15 PM 10/26/2026 2:52 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: jfiscus@TOLLBROTHERS.COM

 10/29/2026TRAC:FINAL BUILDINGSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request10/28/2026 11:26:46 AM 10/28/2026 11:26 AM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3039948274 e-Mail: cdawson@TOLLBROTHERS.COM 10/29/2026 2:23:15 PM Final building inspection not approved Electrical corrections 1. Dead front not sitting flush/interfering with kitchen island breaker needs to be adjusted 2. AC requires GFCI protection 3. 125 amp subpanel breaker in main exterior panel in the off position all breakers required to be on 4. Low voltage stub not terminated in junction box on north east exterior of home/not sealed 5. Receptacle south east corner of home in Eve painters Tape is covering bell box unable to verify a receptacle is installed. 6. Lighting controlled outlet in attic is not switched from attic entry point 7. Hardwired oven requires breaker lock 8. Receptacle above fireplace is loose 9. Cord for sump pump has been cut 10. Receptacle for sub pump cord does not reach receptacle location Final building corrections 11. Exhaust vent for water heater required to be 10 feet horizontal or 3 feet vertical from make up air intake 12. Sub pump drain needs to extend 5 feet past foundation 13. Seal exterior penetration where line set is coming through 14. Insulation needs to be permanently attached to attic lid access 15. Recirculating pump installed at hot water heater requires all hot water lines to be insulated in basement. Shut off is required to be installed underwater heater for recirculating line. 16. Fire blocking missing in basement above stair ceiling 17. No burn spray missing in basement and one location bottom of stair ceiling Recall inspection when corrections are completed

 11/02/2026TRAC:RE FINAL BUILDINGSHAWN VALENZUELAINCOMPLETE-85FEEeTRAKiT Inspection Request10/29/2026 2:25:51 PM 10/29/2026 2:25 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3038980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 11/2/2026 12:42:20 PM Final building inspection not approved Corrections from 1st inspection 1. Recirculating pump installed all hot water lines required to be insulated in the basement including half-inch. 2. Install a shut-off below the water heater for the recirculating line. 3. Receptacle supplying sub pump is too far away for sub pump cord extension cord is not a permanent means of power. 4. Missing fire blocking above stair landing in basement ceiling unfinished to finish areas. Recall inspection when corrections are completed Rest of final building OK

 11/03/2026TRAC:RE FINAL BUILDINGSHAWN VALENZUELAAPPROVED FOR COeTRAKiT Inspection Request11/2/2026 1:57:15 PM 11/2/2026 1:57 PM TOLL BROTHERS Contact Name: TOLL BROTHERS Site Address: 5525 VERVAIN TRL Phone: 3938980006 e-Mail: Jfiscus@TOLLBROTHERS.COM 11/3/2026 11:12:30 AM Final building inspection approved All corrections have been completed Electrical, plumbing, mechanical approved