Permit No. 26-1533 Permit Type   RESIDENTIAL REMODEL Site Address   1463 MULLIGAN PL
CASTLE ROCK, CO 80104
Applied   04/30/2026 Applicant   BENNETT BUILDING & DESIGN LLC
Approved   05/13/2026 Owner   DOUGLAS J MACHIN & SUZANNE M MACHIN
Issued   05/14/2026 Contractor  
Parent Permit No.   Description   REMODEL OF KITCHEN AND LIVING ROOM
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 05/18/2026R:ROUGH ELECTRICALVINCE RAPONEAPPROVEDeTRAKiT Inspection Request5/17/2026 9:27:56 AM 5/17/2026 9:27 AM BENNETT BUILDING & DESIGN LLC Contact Name: BENNETT BUILDING & DESIGN LLC Site Address: 1463 MULLIGAN PL Phone: 3032509732 e-Mail: LARRY@BENNETTBUILDINGDESIGN.COM 5/18/2026 1:42:43 PM Rough electrical approved If hard wiring the double oven you will need a breaker lock Future kitchen island circuit

 05/18/2026R:ROUGH FRAMECOLBY RIGGINSPARTIALeTRAKiT Inspection Request5/17/2026 9:27:56 AM 5/17/2026 9:27 AM BENNETT BUILDING & DESIGN LLC Contact Name: BENNETT BUILDING & DESIGN LLC Site Address: 1463 MULLIGAN PL Phone: 3032509732 e-Mail: LARRY@BENNETTBUILDINGDESIGN.COM 5/18/2026 2:16:15 PM 1. Need to inspect fireplace framing and flue 2. Fire blocking needed every ten ft horizontally Kitchen exhaust will be set at 390 cfm, if not able to verify that it is set at 390 cfm make air will need to be provided. Gas ok Dwv ok Water ok

 06/23/2026R:ROUGH FRAMECOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request6/22/2026 5:08:02 AM 6/22/2026 5:08 AM BENNETT BUILDING & DESIGN LLC Contact Name: BENNETT BUILDING & DESIGN LLC Site Address: 1463 MULLIGAN PL Phone: 3032509732 e-Mail: LARRY@BENNETTBUILDINGDESIGN.COM 6/23/2026 2:10:45 PM Approved Check at final and have proof that the fan is set at 390 cfm.

 09/09/2026R:FNL BUILDINGVINCE RAPONECANCELeTRAKiT Inspection Request9/8/2026 12:25:05 PM 9/8/2026 12:25 PM Larry Bennett Kevin 303-618-8333 Contact Name: Larry Bennett Site Address: 1463 MULLIGAN PL Phone: 3032509732 e-Mail: larry@bennettbuildingdesign.com 9/9/2026 8:10:27 AM KEVIN CALLED TO CANCEL 9/9/2026 8:15:10 AM Called building counter to cancel Reschedule

 09/29/2026R:FINAL ELECTRICALVINCE RAPONENOT APPROVED9/29/2026 3:16:34 PM Dish disposal needs gfci protection breaker 35/37 Coffee bar receptacles in kitchen need gfci protection Reschedule final electrical when ready

 09/29/2026R:FNL BUILDINGCOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request9/28/2026 2:36:39 PM 9/28/2026 2:36 PM BENNETT BUILDING & DESIGN LLC Contact Name: BENNETT BUILDING & DESIGN LLC Site Address: 1463 MULLIGAN PL Phone: 3032509732 e-Mail: LARRY@BENNETTBUILDINGDESIGN.COM 9/30/2026 7:26:09 AM 1. Final building ok pending Final electrical.

 10/19/2026R:FINAL ELECTRICALVINCE RAPONEAPPROVEDeTRAKiT Inspection Request10/16/2026 3:05:32 PM 10/16/2026 3:05 PM BENNETT BUILDING & DESIGN LLC Contact Name: BENNETT BUILDING & DESIGN LLC Site Address: 1463 MULLIGAN PL Phone: 3032509732 e-Mail: LARRY@BENNETTBUILDINGDESIGN.COM 10/19/2026 1:51:00 PM Final electrical approved

 10/19/2026R:FNL BUILDINGVINCE RAPONEAPPROVED10/19/2026 2:58:54 PM Final building approved