| 07/28/2026 | R:ROUGH ELECTRICAL | SHAWN VALENZUELA | PARTIAL | Rough electrical in bathroom remodeling | 7/27/2026 6:54:19 AM
7/27/2026 6:54 AM THE AFFORDABLE HANDY COMPANY LLC
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
7/29/2026 7:10:25 AM
Rough electrical inspection partial approved
Notes
1. At time of inspection, new bedroom does not have smoke detector installed talked with contractor and homeowner. Homeowner is opting to do wireless smoke detectors that are integrated throughout the house. Will verify at final these are installed. If hard wire smoke detectors / carbon monoxide are installed schedule rough electrical inspection before drywall is installed.
2. Smoke detectors/carbon monoxide one needed in each new bedroom and 1 within 15 feet of each sleeping area.
3. any electrical circuit that is new/ altered/ extended/ will have to be brought up to current codes 2023 nec.
First floor bathroom and half bathroom electrical approved first floor bedroom electrical approved bedroom addition on west side of home is not complete at this time or basement. Please recall in rough electrical when addition is ready.
|
|
| 07/28/2026 | R:RE-ROUGH MECH | COLBY RIGGINS | NOT APPROVED | water heater vent & bathrooms fan vents | 7/27/2026 10:21:24 PM
7/27/2026 10:21 PM THE AFFORDABLE HANDY COMPANY LLC
Bathrooms remodeling
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
7/28/2026 2:53:10 PM
1. Both exhaust fans in the master bathroom are out of limit per table M 1504.2, please change pipe to 5 in
2. Water heater exhaust pipe can not transition from metal to pvc and please provide combustion air. Make sure the exhaust duct is rigid or flexible Type B Gas Vent material.
|
|
| 07/24/2026 | R:ROUGH PLUMBING | COLBY RIGGINS | PARTIAL | Need rough plumbing in bathroom remodel | 7/23/2026 10:56:50 PM
7/23/2026 10:56 PM THE AFFORDABLE HANDY COMPANY LLC
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
7/30/2026 7:16:06 AM
Master bathroom plumbing ok.
|
|
| 07/30/2026 | R:ROUGH FRAME | COLBY RIGGINS | PARTIAL | Rough frame on bathroom remodel | 7/29/2026 9:42:45 PM
7/29/2026 9:42 PM THE AFFORDABLE HANDY COMPANY LLC
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
7/30/2026 1:25:44 PM
Approved for two added walls in the master bathroom and a small closet in the basement bedroom.
|
|
| 07/30/2026 | R:RE_ROUGH MECH | COLBY RIGGINS | NOT APPROVED | vents in bathrooms & water heater | 7/29/2026 9:36:11 PM
7/29/2026 9:36 PM THE AFFORDABLE HANDY COMPANY LLC
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
7/30/2026 3:09:30 PM
1. Still working on the changing of the pipe of the two exhaust fans in the master bathroom. And the water heater exhaust duct.
|
|
| 07/31/2026 | R:ROUGH MECHANICAL | COLBY RIGGINS | PARTIAL | Air vents in bathroom and water heater | 7/30/2026 9:04:54 PM
7/30/2026 9:04 PM THE AFFORDABLE HANDY COMPANY LLC
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
7/31/2026 1:46:40 PM
Approved
Bathroom exhaust fans ok, water heater pipe ok
|
|
| 08/28/2026 | R:GRND PLUMBING | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 8/27/2026 10:42:47 PM
8/27/2026 10:42 PM THE AFFORDABLE HANDY COMPANY LLC
Grnd plumbing on addition
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
8/28/2026 2:39:01 PM
Ground plumbing not on test.
|
|
| 09/01/2026 | R:GRND PLUMBING | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 8/31/2026 1:34:39 PM
8/31/2026 1:34 PM THE AFFORDABLE HANDY COMPANY LLC
Ground plumbing on addition
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
9/1/2026 12:15:37 PM
Approved
|
|
| 09/30/2026 | R:WALL BRACING | COLBY RIGGINS | NOT APPROVED | eTRAKiT Inspection Request | 9/29/2026 9:38:38 PM
9/29/2026 9:38 PM THE AFFORDABLE HANDY COMPANY LLC
I would like to cover exterior with moisture barrier and start roof. I need to have it look at before it gets covered.
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
9/30/2026 2:56:23 PM
1. All hold downs missing nailing, everything else ok.
|
|
| 10/07/2026 | R:MIDROOF | SHAWN VALENZUELA | APPROVED | Mid roof | 10/6/2026 11:24:36 AM
10/6/2026 11:24 AM THE AFFORDABLE HANDY COMPANY LLC
I would like to have mid roof inspection
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
10/7/2026 8:51:49 AM
Mid roof inspection approved
Notes
Half inch secure shield installed under laminate flat roofing 16 plates per board will verify roof at final inspection
|
|
| 10/16/2026 | R:WTHR RESIS BARRIER | BRETT LONGNECKER | APPROVED | eTRAKiT Inspection Request | 10/15/2026 11:19:15 PM
10/15/2026 11:19 PM THE AFFORDABLE HANDY COMPANY LLC
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
10/16/2026 9:48:25 AM
Wall bracing approved.
Weather barrier approved with conditions:
1. Email photos of incomplete areas within photos uploaded to inspection report.
|
|
| 10/20/2026 | R:PORCH POST REAR | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 10/19/2026 9:48:26 PM
10/19/2026 9:48 PM THE AFFORDABLE HANDY COMPANY LLC
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
|
|
| 11/04/2026 | R:ROUGH PLUMBING | COLBY RIGGINS | NOT APPROVED | Rough plumbing on addition | 11/3/2026 9:12:15 PM
11/3/2026 9:12 PM THE AFFORDABLE HANDY COMPANY LLC
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
11/5/2026 7:17:19 AM
1. Reconnect all plumbing pipes
2. Shower pan test needed
3. Nail plates needed at top plate of master sink
4. Nail plate needed at laundry room at p trap upper floor
5. Nail plates needed at vent at library room upper floor
6. Water lines not complete in basement floor will need to check lines going into the mechanical room
8. Add boka plates at bottom plates of plumbing pipes
Water lines are ok for radiator heat. Need water lines to mechanical room
|
|
| 11/10/2026 | R:ROUGH ELECTRICAL | VINCE RAPONE | NOT APPROVED | eTRAKiT Inspection Request | 11/9/2026 11:33:23 PM
11/9/2026 11:33 PM THE AFFORDABLE HANDY COMPANY LLC
Rough electrical on Addition
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
11/10/2026 1:26:20 PM
Rough electrical is good
Need to stub the 3 exterior lights. Have j box and flashing installed. Reschedule rough electrical when ready.
|
|
| 11/16/2026 | R:ROUGH ELECTRICAL | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 11/15/2026 9:50:01 PM
11/15/2026 9:50 PM THE AFFORDABLE HANDY COMPANY LLC
Flashing on exterior door lights
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
11/16/2026 11:18:53 AM
Rough electrical approved
|
|
| 11/16/2026 | R:ROUGH FRAME | COLBY RIGGINS | NOT APPROVED | eTRAKiT Inspection Request | 11/15/2026 9:56:08 PM
11/15/2026 9:56 PM THE AFFORDABLE HANDY COMPANY LLC
Addition rough frame
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
11/16/2026 2:31:45 PM
Plumbing ok
Did not look at anything else due to no structural plans onsite.
|
|
| 11/17/2026 | R:ROUGH FRAME | COLBY RIGGINS | NOT APPROVED | eTRAKiT Inspection Request | 11/16/2026 9:50:12 PM
11/16/2026 9:50 PM THE AFFORDABLE HANDY COMPANY LLC
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
11/17/2026 1:12:00 PM
Upper floor
1. Ledger at the rear door to the existing house needs 3 ledger locks every 16 in
2. North side window and northeast window calls for 2 kings each side
3. Consult engineer on lvls installed are 3 2x12 at the east window and rear patio door calls for 2 lvl installed 2 2x8
4. Two west side windows call for detail W the Lsta 18 on kings to header, also east window both sides calls for detail
5. Foam needed at all top and bottom plate penetrations
6. H2.5 or strap needed at double roof joist by north east window and southeast double joist
Lower floor
1. Door header on east side calls for 4 2x6 each side of the header installed is 2x4s on one side missing on other side please consult engineer
2. 4 ledger locks on 16 center at east 2x14 ledger
3. Basement east door calls for 2 kings each side
Plumbing ok
Mechanical ok
Deck rough ok
|
|
| 11/19/2026 | R:ROUGH FRAME | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 11/18/2026 3:23:03 PM
11/18/2026 3:23 PM THE AFFORDABLE HANDY COMPANY LLC
Contact Name: THE AFFORDABLE HANDY COMPANY LLC
Site Address: 441 SENTER DR
Phone: 7196443701
e-Mail: CLIVAR02@GMAIL.COM
11/19/2026 12:57:57 PM
Approved
|
|