11/21/2026
10:44 PM
 
Permit No. 26-1396 Permit Type   RESIDENTIAL TRACT Site Address   6057 RENBARGER ST
CASTLE ROCK, CO 80104
Applied   04/20/2026 Applicant   TOLL BROTHERS
Approved   05/05/2026 Owner   TOLL SOUTHWEST LLC C/O PROPERTY TAX DEPARTMENT
Issued   05/13/2026 Contractor  
Parent Permit No.   Description   NEW SINGLE FAMILY DETACHED RESIDENCE
  Notes   6057 Renbarger
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 06/09/2026TRAC:ELEC CONSTR METERSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request6/8/2026 8:35:54 AM 6/8/2026 8:35 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 6/9/2026 10:09:32 AM Construction meter inspection approved

 06/24/2026TRAC:GROUND PLUMBJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request6/23/2026 6:05:19 AM 6/23/2026 6:05 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 6/24/2026 9:57:58 AM APPROVED.

 07/15/2026TRAC:WALL BRACE_SHEATHMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request7/14/2026 6:06:48 AM 7/14/2026 6:06 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com

 07/22/2026TRAC:REQ PRE ROUGH DOCBUILDING COUNTERAPPROVEDeTRAKiT Inspection Request7/21/2026 12:21:29 PM 7/21/2026 12:21 PM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com

 08/10/2026TRAC:WEATHER RESISTIVE BARRJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request8/10/2026 6:02:40 AM 8/10/2026 6:02 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 8/10/2026 1:06:00 PM APPROVED.

 08/11/2026TRAC:ROUGH ELECTRICALVINCE RAPONEAPPROVEDeTRAKiT Inspection Request8/10/2026 10:31:44 AM 8/10/2026 10:31 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 8/11/2026 11:11:56 AM Rough electrical approved

 08/11/2026TRAC:ROUGH FRAMECOLBY RIGGINSINCOMPLETE-85FEEeTRAKiT Inspection Request8/10/2026 10:30:50 AM 8/10/2026 10:30 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 8/11/2026 3:25:34 PM 1. Missing rear deck ledger lag bolts at the house at all trusses. 2. Trusses E 05 at the rear porch not sitting fully in the hangers 3. Rear first floor of the house at 3 2x6 headers the trimmers are not tight to the bottom plate please shim 4. Remove combustibles off the fireplace 5. FHA plate needed at 3in plumbing pipe on the exterior inside entry door of two car side garage, and double 2 in plumbing pipes next to it 6. At two ply girder in the two car side garage the trusses are not fully sitting in the hangers 7. missing screws at fha plate at kitchen exhaust fha plate on the back side 8. Missing front deck ledger bolts 9. Missing 3 2x6 stud pack at front door for the steel ibeam 10. Upper stair stringers not fully bearing 11. Trusses B 02 missing lateral bracing at web 5 to 8 at second story rear north side 12. Both Front bathrooms first floor next to single car garage exhaust fan is out of limit per table m1504.2 13. South upper room window missing a second king 14. Bearing block at two ply girder south upper room missing nailing per plans 15. Upper studs above multi slide door are not sitting directly on the bottom plate throughout 16. 3 2x8 needed at windows above multi slide 17. Stud at living room at second floor 3 rd from the rear triple girder at west side 18. Missing fire blocking at yellow wire at closet rear north side 18.5 rear west upper studs at window not fully bearing and need shims 19. Bearing blocks at triple girder rear south and north side missing nailing detail 20. Front elevation triple upper girder north n bathroom one truss is not fully seated in its hanger 21. First floor stair stringers not fully bearing 22. Lower stair stringers not fully bearing 23. Cs missing on both sides of the stair landing and are not long enough at the top for connection 24. Missing 2 hts20s and 2 cs16 at multiple stair locations 25. Gas iso does not match what is installed. Water ok Dwv ok Need gas

 08/11/2026TRAC:PORCH POST REARCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request8/11/2026 6:05:50 AM 8/11/2026 6:05 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 8/11/2026 3:26:14 PM Approved

 08/11/2026TRAC:FIRE RESISTCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request8/11/2026 6:05:11 AM 8/11/2026 6:05 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 8/11/2026 3:26:17 PM Approved

 08/17/2026TRAC:RE-ROUGH FRAMECOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request8/13/2026 8:22:48 AM 8/13/2026 8:22 AM TOLL SOUTHWEST SEE CR25-0649 Colby or CR inspector, please do a 30 minute call of text ahead, plumber wants to go over the Iso with you, he sized the gas to 1.25, and the HO eliminated the gas stub at the porch and Carlos needs to see what item 17 is? could not determine what this was for? thank you Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 8/17/2026 10:48:07 AM Approved Dwv ok Water ok Gas ok Gas appliances installed furnace, furnace, water heater, fireplace, range

 08/20/2026TRAC:INSULATIONJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request8/19/2026 6:00:19 AM 8/19/2026 6:00 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 8/20/2026 11:50:16 AM APPROVED.

 09/01/2026TRAC:LATH_STONE_BRICK_STUCCOVINCE RAPONEAPPROVEDeTRAKiT Inspection Request8/31/2026 7:48:27 AM 8/31/2026 7:48 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 9/1/2026 1:34:44 PM Lath approved

 09/02/2026TRAC:SHEAR WALLSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request9/1/2026 8:24:11 AM 9/1/2026 8:24 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 9/2/2026 12:03:25 PM Shear wall inspection approved

 10/01/2026TRAC:ILC REVIEWBUILDING COUNTERAPPROVEDCB9/30/2026 7:52:18 AM 9/30/2026 7:52 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com

 10/01/2026D:REQ GRADE CERT REVADAN RIVASAPPROVEDeTRAKiT Inspection Request9/30/2026 7:48:58 AM 9/30/2026 7:48 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com

 10/19/2026U:HE TOILETWILLIAM BROWNAPPROVEDeTRAKiT Inspection Request10/14/2026 8:36:19 AM 10/14/2026 8:36 AM TOLL SOUTHWEST SEE CR25-0649 5 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com

 10/19/2026D:FINAL DESCJOHN GRAHNAPPROVEDeTRAKiT Inspection Request10/14/2026 8:35:25 AM 10/14/2026 8:35 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com

 10/21/2026U: METER SETGRANT TAYLORAPPROVED

 10/27/2026TRAC: FINAL DOC REVIEWBUILDING COUNTERAPPROVEDCB10/27/2026 6:05:00 AM 10/27/2026 6:04 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com

 11/10/2026TRAC:FINAL BUILDINGSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request11/9/2026 7:43:42 AM 11/9/2026 7:43 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 11/10/2026 2:58:25 PM Final Building inspection not approved electrical corrections 1. west ac does not have proper clearance of 3 feet 2. both ac required gfci protection 3. both ac breakers are oversized 4. breakers in 2 car garage panel are in the off position all breakers required to be turned on 5. light switch located on 1st floor closet by rv garage door buried light behind drywall 6. receptacle for light up mirror 1st floor full bath require gfci protection 7. light switch for fireplace not sitting flush 8. hardwire oven requires breaker lock 9. all receptacles in primary bathroom required gfci protection including receptacles for light up mirrors notes update electrical contractor info on permit sub pump receptacle has double gfci protection. protected at the device and breaker may cause unnecessary troubleshooting and confusion for homeowner final building corrections 1. hose bib at front north west corner loose 2. seal all holes in rv garage including attic access 3. hood damper not functioning properly recall inspection when all corrections are completed

 11/12/2026TRAC:RE-FINAL BUILDINGSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request11/11/2026 11:43:23 AM 11/11/2026 11:43 AM TOLL SOUTHWEST SEE CR25-0649 Note- item 5 under electrical, light switch is for holiday lights in the soffits, per the HO selections, and the electric contractor information should now be updated Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 11/12/2026 9:56:45 AM Final building inspection not approved. 1. Seal attic access in RV garage. 2. Switched outlets for future light-up mirrors; GFCI needs to be readily accessible in the first-floor first bath and primary bath. 3. Receptacle in primary bath outside of toilet room requires GFCI protection. Recall final building inspection when all corrections are completed. Plumbing, mechanical approved.

TRAC:RE-FINAL BUILDINGTRACT INSPECTOR BeTRAKiT Inspection Request11/12/2026 9:58:08 AM 11/12/2026 9:58 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com

 11/17/2026TRAC:RE-FINAL BUILDINGSHAWN VALENZUELAAPPROVED FOR COeTRAKiT Inspection Request11/16/2026 6:10:13 AM 11/16/2026 6:10 AM TOLL SOUTHWEST SEE CR25-0649 Contact Name: TOLL SOUTHWEST SEE CR25-0649 Site Address: 6057 RENBARGER ST Phone: 3037098942 e-Mail: shoogeboom@tollbrothers.com 11/17/2026 9:49:11 AM Final building inspection approved All corrections have been completed Electrical, plumbing, mechanical approved