| 06/09/2026 | TRAC:ELEC CONSTR METER | SHAWN VALENZUELA | NOT APPROVED | eTRAKiT Inspection Request | 6/8/2026 3:30:26 PM
6/8/2026 3:30 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
6/9/2026 12:47:56 PM
Electrical construction meter not approved
1. Receptacle that is installed in temp meter needs to be replaced. Hot terminal is damaged/ melted
Please recall inspection when receptacle is replaced
|
|
| 06/10/2026 | TRAC:ELEC CONSTR METER | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 6/9/2026 12:57:53 PM
6/9/2026 12:57 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
6/10/2026 2:53:40 PM
Electrical construction meter inspection approved
|
|
| 06/23/2026 | TRAC:GROUND PLUMB | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 6/22/2026 10:56:09 PM
6/22/2026 10:56 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
6/23/2026 1:38:07 PM
APPROVED.
|
|
| 07/13/2026 | TRAC:WALL BRACE_SHEATH | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 7/10/2026 2:12:14 PM
7/10/2026 2:12 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
7/13/2026 1:34:52 PM
1. HD strap at the NE corner of the base,ent is missing double stud backing. Only penetrating 1 stud.
|
|
| 07/15/2026 | TRAC:WALL BRACE_SHEATH | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 7/14/2026 9:10:06 AM
7/14/2026 9:10 AM Nick Keane
Correction made
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
7/15/2026 12:14:13 PM
Corrections made
7/15/2026 12:26:03 PM
Corrections made
|
|
| 08/07/2026 | TRAC:REQ PRE ROUGH DOC | BUILDING COUNTER | NOT APPROVED | CB | 8/6/2026 1:05:33 PM
8/6/2026 1:05 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
8/7/2026 8:15:22 AM
MISSING NO BURN DOCUMENT
|
|
| TRAC:ROUGH ELECTRICAL | TRACT INSPECTOR B | | eTRAKiT Inspection Request | 8/10/2026 10:18:22 AM
8/10/2026 10:18 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
|
|
| TRAC:ROUGH FRAME | TRACT INSPECTOR B | | eTRAKiT Inspection Request | 8/10/2026 10:18:22 AM
8/10/2026 10:18 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
|
|
| 08/11/2026 | TRAC:REQ PRE ROUGH DOC | BUILDING COUNTER | APPROVED | CB | 8/10/2026 10:18:22 AM
8/10/2026 10:18 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
|
|
| 08/11/2026 | TRAC:WEATHER RESISTIVE BARR | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 8/10/2026 10:18:22 AM
8/10/2026 10:18 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
8/10/2026 10:53:27 PM
8/10/2026 10:53 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
8/11/2026 1:54:02 PM
APPROVED
UPDATE: BY INSPECTOR JOE CARBAUGH, 08/11/26 12:20 WEATHER RESISTANCE BARRIER CHANGED FROM APPROVED TO NOT APPROVED DUE TO MISSING WINDOW ON RIGHT ELEVATION WALKOUT BASEMENT.
NOTE: PLEASE RECALL WHEN ITEM HAS BEEN CORRECTED.
|
|
| 08/11/2026 | TRAC:ROUGH DECK | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 8/10/2026 10:18:23 AM
8/10/2026 10:18 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
8/11/2026 1:54:04 PM
APPROVED.
|
|
| 08/11/2026 | TRAC:PORCH POST REAR | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 8/10/2026 10:18:22 AM
8/10/2026 10:18 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
8/11/2026 1:54:07 PM
APPROVED.
|
|
| 08/11/2026 | TRAC:FIRE RESIST | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 8/10/2026 10:18:22 AM
8/10/2026 10:18 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
8/11/2026 1:54:09 PM
APPROVED-
|
|
| 08/12/2026 | TRAC:ROUGH FRAME | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 8/11/2026 11:16:35 PM
8/11/2026 11:16 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
8/12/2026 12:00:40 PM
1. Steel posting for option 26373, 16' slider in great room is missing. Also no plan for post in in walk out basement with this option.
2. Missing window in basement.
3. Clean flammables off fireplace.
Note: furnace exhaust is within 3 ft vertically and 3 ft horizontally of an operable window.
Gas approved
Rough Plumbing approved
Rough Mechanical approved ( Pending moving exhaust for final)
8/12/2026 1:38:29 PM
1. Steel posting for option 26373, 16' slider in great room is missing. Also no plan for post in in walk out basement with this option.
2. Missing window in basement.
3. Clean flammables off fireplace.
Note: furnace exhaust is within 3 ft vertically and 3 ft horizontally of an operable window.
Gas approved
Rough Plumbing approved
Rough Mechanical approved ( Pending moving exhaust for final)
8/12/2026 2:09:18 PM
1. Steel posting for option 26373, 16' slider in great room is missing. Also no plan for post in in walk out basement with this option.
2. Missing window in basement.
3. Clean flammables off fireplace.
Note: furnace exhaust is within 3 ft vertically and 3 ft horizontally of an operable window.
Gas approved
Rough Plumbing approved
Rough Mechanical approved ( Pending moving exhaust for final)
|
|
| 08/12/2026 | TRAC:ROUGH ELECTRICAL | SHAWN VALENZUELA | NOT APPROVED | eTRAKiT Inspection Request | 8/11/2026 11:16:35 PM
8/11/2026 11:16 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
8/12/2026 1:15:46 PM
Rough electrical inspection, not approved
1. Add receptacle 2nd floor right back bedroom for wall space 24inches or larger
2. Radon fan in attic 2nd floor left front bedroom no junction box or power installed
3. Future solar flex missing j box in attic
4. Missing ceiling junction box for light above sink in 2nd floor right front bathroom
Recall rough electrical inspection when corrections are completed
Notes
Upload new documentation of wire nuts being used as material has changed to what was originally submitted to the town of Castle rock.
|
|
| 08/17/2026 | TRAC:RE-ROUGH ELECTRICAL | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 8/16/2026 8:44:02 PM
8/16/2026 8:44 PM Nick Keane
Engineer letter for double stacked slider in attachments
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
8/17/2026 12:27:57 PM
Rough electrical inspection approved
All corrections have been completed
|
|
| 08/17/2026 | TRAC:RE-ROUGH FRAME | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 8/16/2026 8:44:02 PM
8/16/2026 8:44 PM Nick Keane
Engineer letter for double stacked slider in attachments
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
8/17/2026 1:25:44 PM
Missing window in basement, if window is dried in and rough electric passes, you are good for insulation. Please recall rough frame with insulation.
|
|
| 08/24/2026 | TRAC:RE-ROUGH FRAME | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 8/23/2026 10:09:35 PM
8/23/2026 10:09 PM Nick Keane
Window in basement covered
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
8/24/2026 9:38:00 AM
Rough frame approved
|
|
| 08/24/2026 | TRAC:INSULATION | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 8/23/2026 10:09:35 PM
8/23/2026 10:09 PM Nick Keane
Window in basement covered
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
8/24/2026 9:38:03 AM
Insulation approved
|
|
| 09/01/2026 | TRAC:WEATHER RESISTIVE BARR | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 8/31/2026 1:57:42 PM
8/31/2026 1:57 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
9/1/2026 1:34:39 PM
Weather resistant approved
|
|
| 09/01/2026 | TRAC:SHEAR WALL | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 8/31/2026 1:57:42 PM
8/31/2026 1:57 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
9/1/2026 1:34:42 PM
Shear wall approved
|
|
| 09/10/2026 | TRAC:LATH_STONE_BRICK_STUCCO | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 9/9/2026 2:08:55 PM
9/9/2026 2:08 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
9/10/2026 10:48:50 AM
Lath approved
|
|
| 10/13/2026 | U: METER SET | GRANT TAYLOR | METER INSP FAIL 1 | | 10/13/2026 1:07:14 PM
A $50.00 re-inspection fee will be charged to the building permit. Once corrections have been made, please email your request for a re-inspection to meterset@crgov.com. Please note that we have up to four business days from the initial request to complete the re-inspection.
No placard in the garage, must have placard.
|
|
| 10/19/2026 | U: METER SET | ADRIAN GODINEZ | APPROVED | | |
|
| 11/03/2026 | U:HE TOILET | WILLIAM BROWN | APPROVED | eTRAKiT Inspection Request | 11/2/2026 2:48:24 PM
11/2/2026 2:48 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
|
|
| 11/12/2026 | TRAC:ILC REVIEW | BUILDING COUNTER | APPROVED | CB | 11/10/2026 2:11:08 PM
11/10/2026 2:11 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
|
|
| 11/12/2026 | D:REQ GRADE CERT REV | JOHN GRAHN | APPROVED | eTRAKiT Inspection Request | 11/10/2026 2:11:07 PM
11/10/2026 2:11 PM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
|
|
| 11/13/2026 | D:FINAL DESC | LUKE HALVORSON | APPROVED | eTRAKiT Inspection Request | 11/12/2026 9:46:58 AM
11/12/2026 9:46 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
|
|
| 11/16/2026 | TRAC: FINAL DOC REVIEW | BUILDING COUNTER | APPROVED | CB | 11/13/2026 9:21:52 AM
11/13/2026 9:21 AM Nick Keane
Contact Name: Nick Keane
Site Address: 1436 OREHOSKY PL
Phone: 2816787538
e-Mail: nkeane@tollbrothers.com
|
|