Permit No. 26-0642 Permit Type   BASEMENT FINISH Site Address   3140 MASTERS PT
CASTLE ROCK, CO 80104
Applied   02/24/2026 Applicant  
Approved   03/17/2026 Owner   GAY C BOCKS & DAVID M BOCKS
Issued   03/19/2026 Contractor  
Parent Permit No.   Description   BASEMENT FINISH
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 03/20/2026R:ROUGH ELECTRICALSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request3/19/2026 1:02:31 PM 3/19/2026 1:02 PM 5 STAR BASEMENT FINISH Contact Name: 5 STAR BASEMENT FINISH Site Address: 3140 MASTERS PT Phone: 7206718984 e-Mail: 303CONTRACTOR@GMAIL.COM 3/20/2026 12:19:32 PM Rough electrical not approved 1: wire above smoke detector junction box needs to be terminated into a junction box. Please call in rough electrical when corrections have been completed

 03/20/2026R:ROUGH FRAMEJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request3/19/2026 1:07:27 PM 3/19/2026 1:07 PM 5 STAR BASEMENT FINISH Contact Name: 5 STAR BASEMENT FINISH Site Address: 3140 MASTERS PT Phone: 7206718984 e-Mail: 303CONTRACTOR@GMAIL.COM 3/20/2026 2:15:39 PM NOT APPROVED- 1) COMPLETE ROUGH ELECTRIC ELECTRICAL INSPECTION. 2) MISSING FIRE-BLOCKING IN CONCEALED SPACES AND TOP PLATE PENETRATIONS. REST OF FROUGH FRAME - OK. NOTE: REVIEWED SMOKE ALARM AND CARBON MONOXIDE REQUIREMENTS WITH CONTRACTOR FOR FINAL.

 04/09/2026R:RGH FRAMESHAWN VALENZUELANOT APPROVED72067189484/9/2026 11:35:22 AM Inspector JOCA changed the inspection assignment from JOCA to SHVA 4/9/2026 12:21:44 PM Rough frame not approved 1. Please add draft stopping/ fire blocking above sump pump. 2. Please add draft stopping/ fire blocking in basement bedroom above concealed spaces south west corner of bedroom in furred out wall.

 04/09/2026R:RGH ELECTSHAWN VALENZUELAAPPROVED72067189484/9/2026 12:21:47 PM Rough electrical approved All connections have been completed Will verify on final electrical inspection that access panel is installed in basement bedroom south west corner of wall. Electrical junction box is located behind the framing. Will need to be accessible.

 04/13/2026R:RE_ROUGH FRAMECOLBY RIGGINSAPPROVED72067189484/13/2026 1:03:58 PM Approved

 10/26/2026R:FINAL BUILDING BASEMENT**SHAWN VALENZUELANOT APPROVED10/26/2026 3:20:59 PM Final building basement inspection not approved 1. Revise plans showing basement as one room when new plans are up loaded contact front building counter for plans to be reviewed 2. Add weather stripping to mechanical room doors x2 doors. 3. Smoke detectors and carbon monoxide detectors are not communicating with each other or through out the house 4. Receptacle buried behind drywall in the back room left of the mechanical room door. Recall inspection when corrections are completed Plumbing, mechanical approved