| 06/03/2026 | R:GRND PLUMBING | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 6/2/2026 10:36:33 AM
6/2/2026 10:36 AM ALLEN & SONS PLUMBING AND HEATING
Contact Name: ALLEN & SONS PLUMBING AND HEATING
Site Address: 595 GRANGER CT
Phone: 3032630142
e-Mail: ADMIN@ALLENSONSPLUMBING.COM
|
|
| 07/28/2026 | D:FINAL DESC | ADAN RIVAS | CANCEL | Need inspection of outlook connections | 7/27/2026 11:30:47 AM
7/27/2026 11:30 AM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Need inspection of soffits and eaves framing so we can install soffit and eave finish material.
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9702489512
e-Mail: RICK@NSCMLLC.COM
7/28/2026 1:23:09 PM
Called in the wrong inspection. You need a building inspection not DESC inspection. Not close to a Final DESC Inspection yet. Cancelling DESC INSPECTION
|
|
| 07/29/2026 | R:FIRE RESISTIVE | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 7/28/2026 12:32:31 PM
7/28/2026 12:32 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Inspection of soffit and eaves only, so we can start installing finish material.
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
7/29/2026 11:04:52 AM
Approved
Side eves ok
Looked at the rear eves, front eve and there hangers, do not cover the porches.
|
|
| 07/31/2026 | R:ROUGH ELECTRICAL | VINCE RAPONE | PARTIAL | eTRAKiT Inspection Request | 7/30/2026 10:19:35 AM
7/30/2026 10:19 AM I&C POWER
Partial rough for exterior soffit deck lighting, on site is Kaden 575-706-7315
Contact Name: I&C POWER
Site Address: 595 GRANGER CT
Phone: 7196960495
e-Mail: accountspayable@I-CPOWER.COM
7/31/2026 7:18:30 AM
Inspector SHVA changed the inspection assignment from SHVA to VIRA
7/31/2026 10:35:24 AM
Soffits and above deck rough electrical approved
Schedule rough electrical when ready
|
|
| 08/03/2026 | R:ROUGH PLUMBING | MARTIN MAGERS | CANCEL | partial rough for gas line for fire pit | 7/31/2026 3:57:43 PM
7/31/2026 3:57 PM ALLEN & SONS PLUMBING AND HEATING
Contact Name: ALLEN & SONS PLUMBING AND HEATING
Site Address: 595 GRANGER CT
Phone: 3032630142
e-Mail: ADMIN@ALLENSONSPLUMBING.COM
8/3/2026 8:02:31 AM
amanda called to cancel
|
|
| 08/07/2026 | R:ROUGH PLUMBING | MARTIN MAGERS | PARTIAL | Partial- gas line for exterior fire pit | 8/3/2026 3:44:28 PM
8/3/2026 3:44 PM ALLEN & SONS PLUMBING AND HEATING
pressure test prior to pouring patio
Contact Name: ALLEN & SONS PLUMBING AND HEATING
Site Address: 595 GRANGER CT
Phone: 3032630142
e-Mail: ADMIN@ALLENSONSPLUMBING.COM
8/10/2026 7:07:20 AM
Gas line from house to fire pit approved.
|
|
| 08/11/2026 | R:PORCH POST FRONT | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 8/10/2026 8:52:48 PM
8/10/2026 8:52 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
8/11/2026 3:26:08 PM
Approved
|
|
| 08/11/2026 | R:PORCH POST REAR | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 8/10/2026 8:51:47 PM
8/10/2026 8:51 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
8/11/2026 3:26:10 PM
Approved
|
|
| 08/17/2026 | R:WALL BRACING | COLBY RIGGINS | NOT APPROVED | eTRAKiT Inspection Request | 8/15/2026 9:29:06 AM
8/15/2026 9:29 AM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Partial sheathing and sheer wall, so we can Lath for Stucco.
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
8/17/2026 11:58:18 AM
1. Consult engineer on all over hangs at the bottom plate on the exterior.
|
|
| 08/17/2026 | R:GAS PIPE AIR TEST | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 8/12/2026 11:38:34 AM
8/12/2026 11:38 AM ALLEN & SONS PLUMBING AND HEATING
Contact Name: ALLEN & SONS PLUMBING AND HEATING
Site Address: 595 GRANGER CT
Phone: 3032630142
e-Mail: ADMIN@ALLENSONSPLUMBING.COM
|
|
| 08/17/2026 | R:RE-ROUGH PLUMB | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 8/12/2026 11:26:50 AM
8/12/2026 11:26 AM ALLEN & SONS PLUMBING AND HEATING
Contact Name: ALLEN & SONS PLUMBING AND HEATING
Site Address: 595 GRANGER CT
Phone: 3032630142
e-Mail: ADMIN@ALLENSONSPLUMBING.COM
|
|
| 08/17/2026 | R:RGH ELECT | VINCE RAPONE | CANCEL | | 8/17/2026 1:30:52 PM
No rough electrical at this time
|
|
| 08/18/2026 | R:ELEC CONSTR MTR | VINCE RAPONE | NOT APPROVED | eTRAKiT Inspection Request | 8/17/2026 2:22:19 PM
8/17/2026 2:22 PM I&C POWER
Service inspection on main meter
Call Kaden 575-706-7315
Contact Name: I&C POWER
Site Address: 595 GRANGER CT
Phone: 7196960495
e-Mail: accountspayable@I-CPOWER.COM
8/18/2026 11:03:44 AM
Need electrical rough complete before I can release the meter
Schedule rough electrical when ready
|
|
| 08/20/2026 | R:ROUGH MECHANICAL | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 8/19/2026 10:12:58 AM
8/19/2026 10:12 AM GENTLE WIND LLC HEATING & AC
Contact Name: GENTLE WIND LLC HEATING & AC
Site Address: 595 GRANGER CT
Phone: 7192899855
e-Mail: GENTLEWIND2019@GMAIL.COM
|
|
| 08/21/2026 | R:WALL BRACING | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 8/20/2026 12:49:01 PM
8/20/2026 12:49 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
8/21/2026 9:52:31 AM
Approved
Engineer letter uploaded
|
|
| 08/21/2026 | R:ROUGH ELECTRICAL | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 8/21/2026 4:53:32 AM
8/21/2026 4:53 AM I&C POWER
Rough inspection, onsite contact Kaden 575-706-7315
Contact Name: I&C POWER
Site Address: 595 GRANGER CT
Phone: 7196960495
e-Mail: accountspayable@I-CPOWER.COM
8/21/2026 12:58:18 PM
Rough electrical approved
Okay to release meter
Note -
remove island plug and put in j box underneath for future use - will check at final (2023 Nec 210.52)
Add receptacle at garage entry - will check at final
|
|
| 08/24/2026 | R:ROUGH FRAME | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 8/21/2026 2:48:21 PM
8/21/2026 2:48 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
8/24/2026 11:19:03 AM
NOT APPROVED-
1) ROOF JACKS NOT DRIED IN / MASTER BEDROOM & MASTER HALL.
2) MISSING COMPLETE FIRE BLOCKING FOR LID / AT GREAT ROOM FIRE.
3) COMBUSTIBLES ON GREAT ROOM FIREPLACE.
4) MISSING NAILS IN BOTTOM LSSR410Z HANGERS AT ALL TGI ROOF JOISTS. NOT THE LVL 'S.
5) MISSING LID FOR FIRE-BLOCKING ABOVE WINE WAGON WHEEL/ DINNING ROOM.
6) MISSING FIRE-BLOCKING FOR ELECTRICAL SOLE PLATE PENETRATION/ MAIN ENTRANCE RIGHT WALL.
7) MISSING FIRE BLOCKING AT CONCEALED SPACE LID / BASEMENT BATHROOM.
8) MISSING FIRE BLOCKING AT T.O.W. / IN BASEMENT WEST/ BEDROOM 5 / ABOVE WINDOW.
9) H2.5A'S AT 4x4 POST FOR BASEMENT STAIRS HAVE BEEN ALTERED FROM MANUFACTURING SPECS/ PLEASE VERIFY FROM A COLORADO DESIGN PROFESSIONAL IF OK AS IT STANDS OR REPAIR.
10) REST OF FRAME - OK.
NOTE: 1) ALL DRAIN CLEAN OUTS TO BE ACCESSIBLE AND CHECKED AT FINAL. LIST BELOW.
LOUNGE SOUTH WALL
GOLF SIMULATOR ROOM / SOUTH WALL.
GYM/ EAST WALL.
NOTE: 2, CRAWL SPACE & FINISHED BASEMENT/ REAR LID & PORCH,
|
|
| 08/26/2026 | R:LATH_STONE_BRICK | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 8/25/2026 1:04:45 PM
8/25/2026 1:04 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Lath for Stucco for all exterior.
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
8/26/2026 11:02:39 AM
APPROVED.
|
|
| 08/26/2026 | R:INSULATION | JOE CARBAUGH | PARTIAL | eTRAKiT Inspection Request | 8/25/2026 1:03:30 PM
8/25/2026 1:03 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Partial for Foam Spray. Hybrid system so need to inspect foam spray first, so we can batt for final inpsection.
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
8/26/2026 11:02:42 AM
PARTIAL-
NOTE: SPRAY FOAM INSULATION IN WALLS & CEILING OK PER INSULATION CERTIFICATE. BATT INSULATION TO BE INSPECTED AT FUTURE INSPECTION.
|
|
| 08/26/2026 | R:WTHR RESIS BARRIER | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 8/25/2026 1:02:20 PM
8/25/2026 1:02 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
8/26/2026 11:02:44 AM
APPROVED-
1) ALL PENETRATIONS & WINDOW WTHR RESIS - OK.
|
|
| 08/26/2026 | R:ROUGH FRAME | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 8/25/2026 1:01:51 PM
8/25/2026 1:01 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
8/26/2026 11:02:47 AM
APPROVED-
NOTE: ALL RGH MEP'S HAVE BEEN APPROVED.
CRAWL SPACE & FINISHED BASEMENT / FRONT & REAR LID & PORCH.
|
|
| 09/01/2026 | R:INSULATION | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 8/31/2026 8:07:25 AM
8/31/2026 8:07 AM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
9/1/2026 12:15:34 PM
Approved
ESR and installer certificate uploaded to the site.
|
|
| 09/04/2026 | R:SHEAR WALL_DRYWALL | COLBY RIGGINS | CANCEL | eTRAKiT Inspection Request | 9/3/2026 11:37:17 AM
9/3/2026 11:37 AM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
9/4/2026 7:25:41 AM
Canceled per superintendent Rick
|
|
| 09/08/2026 | R:SHEAR WALL_DRYWALL | COLBY RIGGINS | PARTIAL | eTRAKiT Inspection Request | 9/4/2026 12:16:37 PM
9/4/2026 12:16 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
9/8/2026 2:24:33 PM
1. Master bathroom is going to have a dry sauna and is installing different materials then moisture barrier drywall. Please uploaded manufacturer specs.
|
|
| 09/16/2026 | R:SHEAR WALL_DRYWALL | COLBY RIGGINS | NOT APPROVED | eTRAKiT Inspection Request | 9/15/2026 7:41:19 AM
9/15/2026 7:41 AM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
9/16/2026 10:55:33 AM
1. Master shower not complete yet. Architect letter uploaded, please call in the inspection once complete.
|
|
| 10/05/2026 | U: METER SET | GRANT TAYLOR | METER INSP FAIL 1 | | 10/5/2026 1:49:24 PM
A $50.00 re-inspection fee will be charged to the building permit. Once corrections have been made, please email your request for a re-inspection to meterset@crgov.com. Please note that we have up to four business days from the initial request to complete the re-inspection.
Need placard in garage, also need another copper securement on other side of meter.
|
|
| 10/12/2026 | U: METER SET | GRANT TAYLOR | APPROVED | | |
|
| 10/23/2026 | D:REQ GRADE CERT REV | ADAN RIVAS | NOT APPROVED | eTRAKiT Inspection Request | 10/22/2026 7:12:25 AM
10/22/2026 7:12 AM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
10/23/2026 9:04:02 AM
Need more information. See drawing for comments.
|
|
| 10/23/2026 | R:SHEAR WALL_DRYWALL | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 10/21/2026 10:17:25 AM
10/21/2026 10:17 AM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
|
|
| 10/23/2026 | D:FINAL DESC | ADAN RIVAS | APPROVED | eTRAKiT Inspection Request | 10/22/2026 7:12:46 AM
10/22/2026 7:12 AM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
|
|
| 10/26/2026 | D:REQ GRADE CERT REV | ADAN RIVAS | NOT APPROVED | Revise GC. See drawing | |
|
| 10/28/2026 | D:REQ GRADE CERT REV | JOHN GRAHN | NOT APPROVED | eTRAKiT Inspection Request | 10/28/2026 5:52:03 AM
10/28/2026 5:52 AM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
|
|
| 10/28/2026 | R:FINAL ELECTRICAL | VINCE RAPONE | NOT APPROVED | eTRAKiT Inspection Request | 10/27/2026 11:51:41 AM
10/27/2026 11:51 AM I&C POWER
Luke 719-568-4067
Contact Name: I&C POWER
Site Address: 595 GRANGER CT
Phone: 7196960495
e-Mail: accountspayable@I-CPOWER.COM
10/28/2026 12:51:41 PM
Front porch receptacle needs gfci protection
Recepts under outside panel need WR receptacles
Add light in attic off laundry
Label smokes
Blank future kit circuit under sink
Reschedule when ready
|
|
| 10/29/2026 | R:FINAL ELECTRICAL | VINCE RAPONE | APPROVED | eTRAKiT Inspection Request | 10/28/2026 1:21:08 PM
10/28/2026 1:21 PM I&C POWER
Contact Name: I&C POWER
Site Address: 595 GRANGER CT
Phone: 7196960495
e-Mail: accountspayable@I-CPOWER.COM
10/29/2026 9:25:34 AM
Final electrical approved
|
|
| 10/29/2026 | D:REQ GRADE CERT REV | ADAN RIVAS | NOT APPROVED | | 10/29/2026 12:20:41 PM
Get with your engineer to ensure that swale design still meets the requirements to handle the 100 year rain event. Plats show a swale design to convey flows into the Type C inlet.
|
|
| 10/29/2026 | D:FINAL DESC | ADAN RIVAS | APPROVED | eTRAKiT Inspection Request | 8/19/2026 10:12:58 AM
8/19/2026 10:12 AM GENTLE WIND LLC HEATING & AC
Contact Name: GENTLE WIND LLC HEATING & AC
Site Address: 595 GRANGER CT
Phone: 7192899855
e-Mail: GENTLEWIND2019@GMAIL.COM
10/28/2026 7:39:12 AM
10/28/2026 7:39 AM GENTLE WIND LLC HEATING & AC
Contact Name: GENTLE WIND LLC HEATING & AC
Site Address: 595 GRANGER CT
Phone: 7192899855
e-Mail: GENTLEWIND2019@GMAIL.COM
|
|
| 10/30/2026 | R:FINAL MECHANICAL | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 10/29/2026 10:06:05 AM
10/29/2026 10:06 AM GENTLE WIND LLC HEATING & AC
Contact Name: GENTLE WIND LLC HEATING & AC
Site Address: 595 GRANGER CT
Phone: 7192899855
e-Mail: GENTLEWIND2019@GMAIL.COM
10/30/2026 1:28:50 PM
APPROVED.
|
|
| D:REQ GRADE CERT REV | ADAN RIVAS | | VOIDED (AD 11/2/2026) | 10/30/2026 1:18:49 PM
10/30/2026 1:18 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
11/2/2026 5:45:54 PM
Inspection voided by AD. Most recent remarks follow: eTRAKiT Inspection Request
|
|
| 11/03/2026 | R:RE-FINAL BLDG | MARTIN MAGERS | APPROVED FOR CO | eTRAKiT Inspection Request | 11/2/2026 3:18:53 PM
11/2/2026 3:18 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
11/3/2026 1:02:28 PM
All inspections approved.
|
|
| 11/03/2026 | R:FINAL PLUMBING | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 10/28/2026 2:53:24 PM
10/28/2026 2:53 PM ALLEN & SONS PLUMBING AND HEATING
Contact Name: ALLEN & SONS PLUMBING AND HEATING
Site Address: 595 GRANGER CT
Phone: 3032630142
e-Mail: ADMIN@ALLENSONSPLUMBING.COM
|
|
| 11/04/2026 | U:HE TOILET | MICHAEL MURPHREE | NOT APPROVED | eTRAKiT Inspection Request | 11/3/2026 1:21:04 PM
11/3/2026 1:21 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
11/4/2026 9:27:57 AM
Failed x 5 Swiss Madison toilets min of 1.1 gpf. .8 gpf is required to pass inspection
|
|
| 11/04/2026 | D:REQ GRADE CERT REV | ADAN RIVAS | APPROVED | | 11/3/2026 8:15:39 AM
11/3/2026 8:15 AM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
|
|
| D:FINAL DESC | STORMWATER INSPECTOR | | eTRAKiT Inspection Request | 11/4/2026 4:20:13 PM
11/4/2026 4:20 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
5 toilets in total. We are changing out all toilets tomorrow to meet the .8 requirement.
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
|
|
| 11/05/2026 | U:HE TOILET REINSPECTION | WILLIAM BROWN | APPROVED | eTRAKiT Inspection Request | 11/4/2026 4:21:50 PM
11/4/2026 4:21 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
5 Toilets in Total. Where are replacing the toilets tomorrow 11/5 to meet the .8 town requirement
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
|
|
| 11/06/2026 | R:REQ CO REVIEW | BUILDING COUNTER | APPROVED | eTRAKiT Inspection Request | 11/5/2026 2:39:04 PM
11/5/2026 2:39 PM NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Contact Name: NORTHSTAR CONSTRUCTION MANAGEMENT LLC
Site Address: 595 GRANGER CT
Phone: 9703908306
e-Mail: RICK@NSCMLLC.COM
|
|