11/21/2026
10:53 PM
 
Permit No. 26-0433 Permit Type   COMMERCIAL NEW Site Address   2020 TIMBER MILL PKWY
CASTLE ROCK, CO 80109
Applied   02/06/2026 Applicant   John Mahoney
Approved   05/28/2026 Owner   FINDLAY FAMILY PROPERTIES LIMITED PARTNERSHIP
Issued   05/28/2026 Contractor  
Parent Permit No.   Description   FINDLAY TOYOTA AUTOMOTIVE DEALERSHIP MAIN BUILDING
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 06/18/2026B:UFERVINCE RAPONENOT APPROVEDeTRAKiT Inspection Request6/17/2026 2:29:29 PM 6/17/2026 2:29 PM MV POWER SOLUTIONS Site contact: Kelly S - 720-398-7774 Contact Name: MV POWER SOLUTIONS Site Address: 2020 TIMBER MILL PKWY Phone: 7202872305 e-Mail: PROJECTS@MVP-EC.COM 6/18/2026 7:32:18 AM Inspector SHVA changed the inspection assignment from SHVA to VIRA 6/18/2026 9:06:14 AM Ufer needs to extend 20' into the foundation. Move from mason wall to concrete footing. Stub into electrical room Reschedule when ready

 06/24/2026B:UFERVINCE RAPONEAPPROVEDLUCAS 62020220766/24/2026 2:39:48 PM Ufer approved

 07/14/2026B:UNGRD PLUMBMARTIN MAGERSPARTIAL7/14/2026 8:24:27 AM called 7.11 for underground sanitary bathrooms etc Lucas 6202022076 7/14/2026 11:02:37 AM All DWV and Sand Oil in the service reception and show room areas. Water not on test.

 07/15/2026B:UNGRD PLUMBBRETT LONGNECKERPARTIALunder slab water pipe7/14/2026 5:17:39 PM 7/14/2026 5:17 PM MAI MECHANICAL Underground inspection Contact Name: MAI MECHANICAL Site Address: 2020 TIMBER MILL PKWY Phone: 3032899866 e-Mail: INFO@MAI-MECHANICAL.COM 7/15/2026 3:44:16 PM 1 inch and 3/4 inch underground copper pipe ok.

 07/23/2026B:UNGRD PLUMBMARTIN MAGERSPARTIALeTRAKiT Inspection Request7/22/2026 11:22:22 AM 7/22/2026 11:22 AM MAI MECHANICAL LLC (P) Underground Contact Name: MAI MECHANICAL LLC (P) Site Address: 2020 TIMBER MILL PKWY Phone: 3032899866 e-Mail: INFO@MAI-MECHANICAL.COM 7/23/2026 1:26:16 PM Shop underground drains, and show room sand oil, complete and approved. A few pipes were not properly bedded and sloped. Plumbing foreman, Brett, got his crew right on making repairs. Repairs were made before I left.

 07/30/2026B:GROUND PLUMBINGMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request7/29/2026 2:54:07 PM 7/29/2026 2:54 PM MAI MECHANICAL Underground Contact Name: MAI MECHANICAL Site Address: 2020 TIMBER MILL PKWY Phone: 3032899866 e-Mail: INFO@MAI-MECHANICAL.COM 7/30/2026 12:13:10 PM Inspection of car wash ground plumbing. Water line approved. Vents missing bedding and are slopped backwards.

 07/31/2026B:ELECTRICAL UNDERGRVINCE RAPONEPARTIALLUCAS 62020220767/31/2026 7:19:09 AM Inspector SHVA changed the inspection assignment from SHVA to VIRA 7/31/2026 10:35:22 AM Show room under slab 2" data sleeves 3/4 pvc to floor boxes

 08/04/2026B:GROUND PLUMBINGMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request8/3/2026 12:40:01 PM 8/3/2026 12:40 PM Austin Russell Re-inspection of our underground plumbing in the car wash building. Contact Name: Austin Russell Site Address: 2020 TIMBER MILL PKWY Phone: 8282286078 e-Mail: arussell@crossland.com 8/4/2026 2:17:13 PM Corrections made all ground plumbing complete. Ok to cover. 8/4/2026 2:21:07 PM Corrections made all ground plumbing complete. Ok to cover.

 08/06/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALeTRAKiT Inspection Request8/5/2026 7:03:02 AM 8/5/2026 7:03 AM Austin Russell Underground plumbing in our showroom Contact Name: Austin Russell Site Address: 2020 TIMBER MILL PKWY Phone: 8282286078 e-Mail: arussell@crossland.com 8/6/2026 12:10:24 PM Underslab rough electrical- showroom and parts area Branch circuits and feeder pvc

 08/20/2026B:PRECON MEETINGBRETT LONGNECKERAPPROVED8/20/2026 8:49:31 AM Building pre-con with Crossland construction at 8:00 am in Town Council Conference Room. Sign in sheet uploaded to permit.

 09/28/2026B:ELECTRICAL TRENCHVINCE RAPONEPARTIALCOLBY 62021075919/25/2026 3:52:58 PM WEST & NORTH SIDE 9/28/2026 1:21:41 PM 4 - 4" data sleeves from pedestal to building only 1" pvc Site lighting from electrical room to west side - trench only no caissons

 09/30/2026B:RE ROUGH ELECTRICALVINCE RAPONEPARTIALeTRAKiT Inspection Request9/29/2026 3:28:37 PM 9/29/2026 3:28 PM Austin Russell Underground elecrtical for site Contact Name: Austin Russell Site Address: 2020 TIMBER MILL PKWY Phone: 8282286078 e-Mail: arussell@crossland.com 9/30/2026 1:47:15 PM Stubs for SES - 8 - 4" pvc Secondary side SES - to electrical room panel hp hl1 hl2 Surge protector He1 hm2 300kva transformer Once prints have been approved - have a printed set - I want to highlight the one line I've already inspected

 10/07/2026B:ELECTRICAL TRENCHVINCE RAPONEPARTIALeTRAKiT Inspection Request10/6/2026 2:08:19 PM 10/6/2026 2:08 PM Austin Russell Underground site electrical on north side of building Contact Name: Austin Russell Site Address: 2020 TIMBER MILL PKWY Phone: 8282286078 e-Mail: arussell@crossland.com 10/7/2026 10:51:13 AM Site lighting / cameras / gate controls approved to jog road crossing 2 - 1-1/2 lighting controls 8 - 1" pvc

 10/30/2026B:ROUGH ELECTRICALSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request10/29/2026 8:43:44 AM 10/29/2026 8:43 AM Austin Russell Site light pole electrical inspection Contact Name: Austin Russell Site Address: 2020 TIMBER MILL PKWY Phone: 8282286078 e-Mail: arussell@crossland.com 10/30/2026 3:02:50 PM Rough electrical inspection, not approved Note 1. This is a caisson inspection to verify bonding of rebar and light poles. on detail ES 100 shows Cadwell attachment to rebar what is currently installed does not match that detail rebar clamps installed. Recall inspection when corrections are complete completed At next inspection, please have caisson detail on site showing to match what's installed.

 11/06/2026B:ELECTRICAL TRENCHJON WHITEPARTIALeTRAKiT Inspection Request11/5/2026 8:02:51 AM 11/5/2026 8:02 AM Austin Russell Underground site electrical trenches on the north east part of our site. Contact Name: Austin Russell Site Address: 2020 TIMBER MILL PKWY Phone: 8282286078 e-Mail: arussell@crossland.com 11/6/2026 11:19:47 AM Partial Electrical U/G Trench - Inspected trenches for parking lighting only, no caisson at NE Corner of Parking Lot as marked on electrical site plans. OK to cover