11/21/2026
10:44 PM
 
Permit No. 26-0319 Permit Type   RESIDENTIAL ADDITION Site Address   5246 FAIRFIELD CIR
CASTLE ROCK, CO 80104
Applied   01/28/2026 Applicant   ZELEM CONSTRUCTION LLC
Approved   06/10/2026 Owner   DENISE M TRIBA & JASON L PALMER
Issued   06/12/2026 Contractor  
Parent Permit No.   Description   ADDITION TO RESIDENCE WITH POOL
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 07/28/2026R:GRND PLUMBINGMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request7/27/2026 4:36:04 PM 7/27/2026 4:36 PM CELTIC IRON PLUMBING LLC Contact Name: CELTIC IRON PLUMBING LLC Site Address: 5246 FAIRFIELD CIR Phone: 7204507710 e-Mail: CELTICIRONPLUMBING@GMAIL.COM 7/28/2026 10:13:42 AM Ground plumbing approved. No permit on site.

 09/15/2026R:WALL BRACINGCOLBY RIGGINSPARTIALeTRAKiT Inspection Request9/14/2026 2:32:40 PM 9/14/2026 2:32 PM ZELEM CONSTRUCTION LLC Contact Name: ZELEM CONSTRUCTION LLC Site Address: 5246 FAIRFIELD CIR Phone: 3034354330 e-Mail: JOHN@ZELEMCONSTRUCTION.COM 9/15/2026 11:49:14 AM Exterior ok to wrap 1. Still need interior shear walls and interior drywall at a few locations.

 09/22/2026R:WTHR RESIS BARRIERCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request9/21/2026 11:18:55 AM 9/21/2026 11:18 AM ZELEM CONSTRUCTION LLC Contact Name: ZELEM CONSTRUCTION LLC Site Address: 5246 FAIRFIELD CIR Phone: 3034354330 e-Mail: JOHN@ZELEMCONSTRUCTION.COM 9/22/2026 3:25:27 PM Approved

R:FINAL PLUMBINGJONATHON WEIKLEeTRAKiT Inspection Request9/29/2026 2:03:44 PM 9/29/2026 2:03 PM CELTIC IRON PLUMBING LLC Contact Name: CELTIC IRON PLUMBING LLC Site Address: 5246 FAIRFIELD CIR Phone: 7204507710 e-Mail: CELTICIRONPLUMBING@GMAIL.COM

 09/30/2026R:ROUGH PLUMBINGCOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request9/29/2026 2:05:10 PM 9/29/2026 2:05 PM CELTIC IRON PLUMBING LLC Contact Name: CELTIC IRON PLUMBING LLC Site Address: 5246 FAIRFIELD CIR Phone: 7204507710 e-Mail: CELTICIRONPLUMBING@GMAIL.COM 9/30/2026 2:52:58 PM 1. Dwv test under 5 psi 2. In crawl space/ basement area needs nail plates on at all the plumbing pipes 3. Water line at at small rear wall needs a nail plate at the bottom plate Did not inspect pool area, or crawl space, gas line not looked at.

 10/01/2026R:RE-ROUGH PLUMBCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request9/30/2026 1:39:55 PM 9/30/2026 1:39 PM CELTIC IRON PLUMBING LLC Contact Name: CELTIC IRON PLUMBING LLC Site Address: 5246 FAIRFIELD CIR Phone: 7204507710 e-Mail: CELTICIRONPLUMBING@GMAIL.COM 10/1/2026 1:21:04 PM Approved Pool water lines and pipe was inspected on 7/28/26 by MM

 10/02/2026R:GAS PIPE AIR TESTJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request10/1/2026 3:10:54 PM 10/1/2026 3:10 PM CELTIC IRON PLUMBING LLC Contact Name: CELTIC IRON PLUMBING LLC Site Address: 5246 FAIRFIELD CIR Phone: 7204507710 e-Mail: CELTICIRONPLUMBING@GMAIL.COM 10/2/2026 9:49:47 AM APPROVED.

 10/12/2026R:ROUGH MECHANICALMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request10/11/2026 2:50:28 PM 10/11/2026 2:50 PM ZELEM CONSTRUCTION LLC Contact Name: ZELEM CONSTRUCTION LLC Site Address: 5246 FAIRFIELD CIR Phone: 3034354330 e-Mail: JOHN@ZELEMCONSTRUCTION.COM 10/12/2026 3:12:23 PM 1. Ductwork over the pool area incomplete. 2. Missing the dehumidifier and heat recovery unit that is shown on V5 M1 of the most recent approved plans.

 10/12/2026R:ROUGH ELECTRICALSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request10/11/2026 2:50:27 PM 10/11/2026 2:50 PM ZELEM CONSTRUCTION LLC Contact Name: ZELEM CONSTRUCTION LLC Site Address: 5246 FAIRFIELD CIR Phone: 3034354330 e-Mail: JOHN@ZELEMCONSTRUCTION.COM 10/12/2026 3:11:49 PM Rough electrical inspection, not approved 1. Provide 6/12 wall spacing for electrical outlets second floor loft. Recall inspection when corrections are completed Notes Swim spa is accessible from crawlspace, please have installation manual/instructions on site at next inspection to verify the requirements for the swim spa insulation. New 200 amp subpanel added in crawlspace of new addition 400 amp new service has not been completed at this time

 10/13/2026R:RE-ROUGH ELECSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request10/12/2026 3:57:22 PM 10/12/2026 3:57 PM ZELEM CONSTRUCTION LLC Contact Name: ZELEM CONSTRUCTION LLC Site Address: 5246 FAIRFIELD CIR Phone: 3034354330 e-Mail: JOHN@ZELEMCONSTRUCTION.COM 10/13/2026 2:36:55 PM Rough electrical inspection not approved Notes Ok to start drywall in new addition only ***** pending rough mechanical, rough plumbing, rough frame***** Have stamped plans on site at next inspection Sub panel feed incomplete will verify when ready need to inspect how Ser was ran through finished basement Have pool specs on site at next inspection to verify bonding requirements Update plans showing what size sub panel is added in pool room/ mechanical room. Wire size, destination of origin. Updated notes by inspector Plans do not show a service upgrade to 400 amps. A permit needs to be issued for this work being completed. this will hold up final inspection

 10/20/2026R:ROUGH FRAMEMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request10/19/2026 5:12:16 PM 10/19/2026 5:12 PM ZELEM CONSTRUCTION LLC Contact Name: ZELEM CONSTRUCTION LLC Site Address: 5246 FAIRFIELD CIR Phone: 3034354330 e-Mail: JOHN@ZELEMCONSTRUCTION.COM 10/20/2026 11:55:14 AM 1. Point load , squash blocking, missing for west loft window. 2. Missing fire blocking in HVAC Chase. 3. Complete point load blocking, squash blocking, from 4 of the large posts down to foundation in crawl space. 4. Consult engineer on attachment of 2 beams the west side of the crawl space. Rough mechanical not passed. Rough electric not passed.

 10/26/2026R:RE ROUGH FRAMEMARTIN MAGERSINCOMPLETE-85FEE10/26/2026 4:03:42 PM 2. Missing fire blocking in HVAC Chase. 3. Complete point load blocking, squash blocking, from 4 of the large posts down to foundation in crawl space. No access to crawl space. Please have ladder set 4. Consult engineer on attachment of 2 beams the west side of the crawl space.

 10/26/2026R:INSULATIONMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request10/22/2026 12:11:22 PM 10/22/2026 12:11 PM ZELEM CONSTRUCTION LLC Contact Name: ZELEM CONSTRUCTION LLC Site Address: 5246 FAIRFIELD CIR Phone: 3034354330 e-Mail: JOHN@ZELEMCONSTRUCTION.COM 10/26/2026 4:03:45 PM Insulation not complete. Rough Frame not approved. Do not proceed to drywall. Please have an ESR, insulation certificate, and paint irredecent spray as needed.

 10/29/2026R:INSULATIONJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request10/28/2026 1:19:15 PM 10/28/2026 1:19 PM ZELEM CONSTRUCTION LLC Contact Name: ZELEM CONSTRUCTION LLC Site Address: 5246 FAIRFIELD CIR Phone: 3034354330 e-Mail: JOHN@ZELEMCONSTRUCTION.COM 10/29/2026 2:32:55 PM APPROVED- 1) MEASURED SPRAY FOAM TO BE AT A MINIMUM OF 3" THICK , PER MANUFACTURER R- VALUES 3" EQUALS R20 PER STAMPED PLANS. NOTE: PLEASE ATTACH ESR TO PERMIT BEFORE FINAL..

 11/10/2026R:SHEAR WALL_DRYWALLMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request11/9/2026 10:47:22 AM 11/9/2026 10:47 AM ZELEM CONSTRUCTION LLC Contact Name: ZELEM CONSTRUCTION LLC Site Address: 5246 FAIRFIELD CIR Phone: 3034354330 e-Mail: JOHN@ZELEMCONSTRUCTION.COM