| 07/28/2026 | R:GRND PLUMBING | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 7/27/2026 4:36:04 PM
7/27/2026 4:36 PM CELTIC IRON PLUMBING LLC
Contact Name: CELTIC IRON PLUMBING LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 7204507710
e-Mail: CELTICIRONPLUMBING@GMAIL.COM
7/28/2026 10:13:42 AM
Ground plumbing approved. No permit on site.
|
|
| 09/15/2026 | R:WALL BRACING | COLBY RIGGINS | PARTIAL | eTRAKiT Inspection Request | 9/14/2026 2:32:40 PM
9/14/2026 2:32 PM ZELEM CONSTRUCTION LLC
Contact Name: ZELEM CONSTRUCTION LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 3034354330
e-Mail: JOHN@ZELEMCONSTRUCTION.COM
9/15/2026 11:49:14 AM
Exterior ok to wrap
1. Still need interior shear walls and interior drywall at a few locations.
|
|
| 09/22/2026 | R:WTHR RESIS BARRIER | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 9/21/2026 11:18:55 AM
9/21/2026 11:18 AM ZELEM CONSTRUCTION LLC
Contact Name: ZELEM CONSTRUCTION LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 3034354330
e-Mail: JOHN@ZELEMCONSTRUCTION.COM
9/22/2026 3:25:27 PM
Approved
|
|
| R:FINAL PLUMBING | JONATHON WEIKLE | | eTRAKiT Inspection Request | 9/29/2026 2:03:44 PM
9/29/2026 2:03 PM CELTIC IRON PLUMBING LLC
Contact Name: CELTIC IRON PLUMBING LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 7204507710
e-Mail: CELTICIRONPLUMBING@GMAIL.COM
|
|
| 09/30/2026 | R:ROUGH PLUMBING | COLBY RIGGINS | NOT APPROVED | eTRAKiT Inspection Request | 9/29/2026 2:05:10 PM
9/29/2026 2:05 PM CELTIC IRON PLUMBING LLC
Contact Name: CELTIC IRON PLUMBING LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 7204507710
e-Mail: CELTICIRONPLUMBING@GMAIL.COM
9/30/2026 2:52:58 PM
1. Dwv test under 5 psi
2. In crawl space/ basement area needs nail plates on at all the plumbing pipes
3. Water line at at small rear wall needs a nail plate at the bottom plate
Did not inspect pool area, or crawl space, gas line not looked at.
|
|
| 10/01/2026 | R:RE-ROUGH PLUMB | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 9/30/2026 1:39:55 PM
9/30/2026 1:39 PM CELTIC IRON PLUMBING LLC
Contact Name: CELTIC IRON PLUMBING LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 7204507710
e-Mail: CELTICIRONPLUMBING@GMAIL.COM
10/1/2026 1:21:04 PM
Approved
Pool water lines and pipe was inspected on 7/28/26 by MM
|
|
| 10/02/2026 | R:GAS PIPE AIR TEST | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 10/1/2026 3:10:54 PM
10/1/2026 3:10 PM CELTIC IRON PLUMBING LLC
Contact Name: CELTIC IRON PLUMBING LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 7204507710
e-Mail: CELTICIRONPLUMBING@GMAIL.COM
10/2/2026 9:49:47 AM
APPROVED.
|
|
| 10/12/2026 | R:ROUGH MECHANICAL | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 10/11/2026 2:50:28 PM
10/11/2026 2:50 PM ZELEM CONSTRUCTION LLC
Contact Name: ZELEM CONSTRUCTION LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 3034354330
e-Mail: JOHN@ZELEMCONSTRUCTION.COM
10/12/2026 3:12:23 PM
1. Ductwork over the pool area incomplete.
2. Missing the dehumidifier and heat recovery unit that is shown on V5 M1 of the most recent approved plans.
|
|
| 10/12/2026 | R:ROUGH ELECTRICAL | SHAWN VALENZUELA | NOT APPROVED | eTRAKiT Inspection Request | 10/11/2026 2:50:27 PM
10/11/2026 2:50 PM ZELEM CONSTRUCTION LLC
Contact Name: ZELEM CONSTRUCTION LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 3034354330
e-Mail: JOHN@ZELEMCONSTRUCTION.COM
10/12/2026 3:11:49 PM
Rough electrical inspection, not approved
1. Provide 6/12 wall spacing for electrical outlets second floor loft.
Recall inspection when corrections are completed
Notes
Swim spa is accessible from crawlspace, please have installation manual/instructions on site at next inspection to verify the requirements for the swim spa insulation.
New 200 amp subpanel added in crawlspace of new addition 400 amp new service has not been completed at this time
|
|
| 10/13/2026 | R:RE-ROUGH ELEC | SHAWN VALENZUELA | NOT APPROVED | eTRAKiT Inspection Request | 10/12/2026 3:57:22 PM
10/12/2026 3:57 PM ZELEM CONSTRUCTION LLC
Contact Name: ZELEM CONSTRUCTION LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 3034354330
e-Mail: JOHN@ZELEMCONSTRUCTION.COM
10/13/2026 2:36:55 PM
Rough electrical inspection not approved
Notes
Ok to start drywall in new addition only ***** pending rough mechanical, rough plumbing, rough frame*****
Have stamped plans on site at next inspection
Sub panel feed incomplete will verify when ready need to inspect how Ser was ran through finished basement
Have pool specs on site at next inspection to verify bonding requirements
Update plans showing what size sub panel is added in pool room/ mechanical room. Wire size, destination of origin.
Updated notes by inspector
Plans do not show a service upgrade to 400 amps. A permit needs to be issued for this work being completed. this will hold up final inspection
|
|
| 10/20/2026 | R:ROUGH FRAME | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 10/19/2026 5:12:16 PM
10/19/2026 5:12 PM ZELEM CONSTRUCTION LLC
Contact Name: ZELEM CONSTRUCTION LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 3034354330
e-Mail: JOHN@ZELEMCONSTRUCTION.COM
10/20/2026 11:55:14 AM
1. Point load , squash blocking, missing for west loft window.
2. Missing fire blocking in HVAC Chase.
3. Complete point load blocking, squash blocking, from 4 of the large posts down to foundation in crawl space.
4. Consult engineer on attachment of 2 beams the west side of the crawl space.
Rough mechanical not passed.
Rough electric not passed.
|
|
| 10/26/2026 | R:RE ROUGH FRAME | MARTIN MAGERS | INCOMPLETE-85FEE | | 10/26/2026 4:03:42 PM
2. Missing fire blocking in HVAC Chase.
3. Complete point load blocking, squash blocking, from 4 of the large posts down to foundation in crawl space. No access to crawl space. Please have ladder set
4. Consult engineer on attachment of 2 beams the west side of the crawl space.
|
|
| 10/26/2026 | R:INSULATION | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 10/22/2026 12:11:22 PM
10/22/2026 12:11 PM ZELEM CONSTRUCTION LLC
Contact Name: ZELEM CONSTRUCTION LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 3034354330
e-Mail: JOHN@ZELEMCONSTRUCTION.COM
10/26/2026 4:03:45 PM
Insulation not complete.
Rough Frame not approved.
Do not proceed to drywall.
Please have an ESR, insulation certificate, and paint irredecent spray as needed.
|
|
| 10/29/2026 | R:INSULATION | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 10/28/2026 1:19:15 PM
10/28/2026 1:19 PM ZELEM CONSTRUCTION LLC
Contact Name: ZELEM CONSTRUCTION LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 3034354330
e-Mail: JOHN@ZELEMCONSTRUCTION.COM
10/29/2026 2:32:55 PM
APPROVED-
1) MEASURED SPRAY FOAM TO BE AT A MINIMUM OF 3" THICK , PER MANUFACTURER R- VALUES 3" EQUALS R20 PER STAMPED PLANS.
NOTE: PLEASE ATTACH ESR TO PERMIT BEFORE FINAL..
|
|
| 11/10/2026 | R:SHEAR WALL_DRYWALL | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 11/9/2026 10:47:22 AM
11/9/2026 10:47 AM ZELEM CONSTRUCTION LLC
Contact Name: ZELEM CONSTRUCTION LLC
Site Address: 5246 FAIRFIELD CIR
Phone: 3034354330
e-Mail: JOHN@ZELEMCONSTRUCTION.COM
|
|