11/21/2026
10:44 PM
 
Permit No. 26-0034 Permit Type   RESIDENTIAL TRACT Site Address   5725 PLEASANT VIEW DR
CASTLE ROCK, CO 80108
Applied   01/05/2026 Applicant   RICHMOND AMERICAN HOMES
Approved   01/20/2026 Owner   RICHMOND AMERICAN HOMES OF COLORADO LLC
Issued   01/20/2026 Contractor  
Parent Permit No.   Description   NEW SINGLE FAMILY DETACHED RESIDENCE
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

TRAC:ELEC CONSTR METERTRACT INSPECTOReTRAKiT Inspection Request2/10/2026 1:36:13 PM 2/10/2026 1:36 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@mdch.com

 02/11/2026TRAC:ELEC CONSTR METERSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request2/10/2026 1:47:19 PM 2/10/2026 1:47 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@mdch.com 2/11/2026 11:49:12 AM Construction meter not approved Per core requirements no ground rods allowed. #6 ground needs to be in same raceway as meter service feed Meter housing is not bounded. Meter housing needs to be bonded to the #6 ground

 02/17/2026TRAC:ELEC CONSTR METERVINCE RAPONEAPPROVEDeTRAKiT Inspection Request2/16/2026 7:40:23 AM 2/16/2026 7:40 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@mdch.com 2/17/2026 10:32:59 AM Meter good No card

 02/18/2026TRAC:GROUND PLUMBCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request2/17/2026 4:17:17 AM 2/17/2026 4:17 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@mdch.com 2/18/2026 3:14:50 PM Approved

 03/02/2026TRAC:WALL BRACE_SHEATHSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request3/1/2026 9:27:39 AM 3/1/2026 9:27 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@mdch.com 3/3/2026 7:04:11 AM Wall brace not approved Over exposed hold downs Back side of single car garage ok to start weather barrier can verify holds if thats installed

 03/05/2026TRAC:WEATHER RESISTIVE BARRCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request3/4/2026 2:21:36 PM 3/4/2026 2:21 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 3/5/2026 1:22:19 PM Approved

 03/05/2026TRAC:WALL BRACE_SHEATHCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request3/4/2026 2:21:36 PM 3/4/2026 2:21 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 3/5/2026 1:22:21 PM Approved

 03/05/2026TRAC:FIRE RESISTCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request3/4/2026 2:21:36 PM 3/4/2026 2:21 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 3/5/2026 1:22:24 PM Approved

 03/10/2026TRAC:REQ PRE ROUGH DOCBUILDING COUNTERAPPROVEDCB3/9/2026 11:31:54 AM 3/9/2026 11:31 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com

 03/11/2026TRAC:REQ PRE ROUGH DOCBUILDING COUNTERAPPROVEDUsing the revised plot plan3/10/2026 2:56:01 PM 3/10/2026 2:56 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 3/11/2026 8:48:21 AM building OK. No deck at this time.

 03/11/2026TRAC:ROUGH DECKBRETT LONGNECKERNOT APPROVEDeTRAKiT Inspection Request3/10/2026 12:41:29 PM 3/10/2026 12:41 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 3/11/2026 9:50:10 AM Deck inspection not conducted. Current deck layout impedes on the approved site building envelope.

 03/11/2026TRAC:PORCH POST REARBRETT LONGNECKERNOT APPROVEDeTRAKiT Inspection Request3/10/2026 12:41:29 PM 3/10/2026 12:41 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 3/11/2026 9:50:12 AM Rear post inspection not conducted. Current post and deck layout impedes on the approved site building envelope.

 03/12/2026TRAC:ROUGH FRAMECOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request3/11/2026 6:46:25 AM 3/11/2026 6:46 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 3/12/2026 1:57:30 PM 1. 2 car garage at 2 ply girder the trusses are not fully seated in there hangers 2. Cannot verify garage entry door header, plans call for 3 2x10 or 3 lsl 3. Dwv line at the laundry room is at 0 psi 4. Laundry room drain in the wall possibly has a leak at the pipe 5. No water at the kitchen Dwv 6. Remove combustibles off the fireplace 7. Need mastic at bathroom exhaust fan right of the front entry 8. Master bedroom second truss from the rear deck door calls for tc 26 on each side of the truss 9. Cannot verify front door entry header of 3 lsl 10. No gas iso onsite 11. Missing squash blocking at left of the stairs rear window in the basement 12. Kitchen island detail installed incorrectly 13. Ledger missing under the basement stairs 3 staggered on 6 in 14. Dissimilar metals touching a copper waterline. Gas test ok, need to inspect gas pipe size Water ok Dwv needed Note Front porch post not installed Did not inspect rear porch

 03/12/2026TRAC:ELEC TRENCHESVINCE RAPONEAPPROVEDeTRAKiT Inspection Request3/11/2026 3:04:02 PM 3/11/2026 3:04 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 3/12/2026 2:34:38 PM Trench good Lateral feeders

 03/12/2026TRAC:ROUGH ELECTRICALVINCE RAPONENOT APPROVEDeTRAKiT Inspection Request3/11/2026 6:46:25 AM 3/11/2026 6:46 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 3/12/2026 2:34:41 PM Need laterals terminated at disconnect No receptacles on the side of island per 210.52 ( counter pop up / in a backsplash / in a j box under sink for future use only ) ( same in basement) Cold water needs bonded below the lowest and above the highest valve. Need one above

 03/16/2026TRAC:RE-ROUGH ELECTRICALSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request3/15/2026 5:24:17 AM 3/15/2026 5:24 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 3/16/2026 10:22:01 AM Rough electrical approved All connections have been completed At this time of rough electrical inspection service laterals to meter pedestal are incomplete

 03/16/2026TRAC:RE-ROUGH FRAMECOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request3/15/2026 5:24:17 AM 3/15/2026 5:24 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 3/16/2026 10:52:16 AM 8. Master bedroom second truss from the rear deck door calls for tc 26 on each side of the truss 13. Ledger missing under the basement stairs 3 staggered on 6 in Gas test ok, need to inspect gas pipe size Water ok Dwv needed Gas appliances fireplace, furnace,range Note Front porch post not installed Did not inspect rear porch

 03/18/2026TRAC:RE-ROUGH FRAMECOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request3/16/2026 2:34:58 PM 3/16/2026 2:34 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 3/18/2026 2:37:47 PM Everything ok pending rear deck in the easement.

 03/18/2026TRAC:INSULATIONCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request3/16/2026 2:34:58 PM 3/16/2026 2:34 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 3/18/2026 2:37:50 PM Approved

 03/23/2026TRAC:SHEAR WALLCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request3/20/2026 9:40:10 AM 3/20/2026 9:40 AM Cory Steckler Contact Name: Cory Steckler Site Address: 5725 PLEASANT VIEW DR Phone: 7202994752 e-Mail: Cory.steckler@mdch.com 3/23/2026 2:26:37 PM Approved

 04/14/2026TRAC:PORCH POST FRONTCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request4/13/2026 7:14:16 AM 4/13/2026 7:14 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 4/14/2026 3:11:52 PM Approved

 04/29/2026TRAC:ROUGH DECKCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request4/28/2026 5:52:51 PM 4/28/2026 5:52 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 4/29/2026 2:06:50 PM Approved

 04/29/2026TRAC:RE-ROUGH FRAMECOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request4/28/2026 5:52:51 PM 4/28/2026 5:52 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 4/29/2026 2:06:53 PM Approved

 04/29/2026TRAC:PORCH POST REARCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request4/28/2026 5:52:51 PM 4/28/2026 5:52 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 4/29/2026 2:06:55 PM Approved

 05/20/2026U: METER SETRYAN CUPANOMETER INSP FAIL 15/20/2026 2:40:37 PM A $50.00 re-inspection fee will be charged to the building permit. Once corrections have been made, please email your request for a re-inspection to meterset@crgov.com. Please note that we have up to four business days from the initial request to complete the re-inspection. Meter inspection failed for: -front door locked, and garage closed (unable to get into the house and complete inspection)

 05/28/2026U: METER SETRYAN CUPANOAPPROVED

 07/09/2026U:HE TOILETWILLIAM BROWNAPPROVEDeTRAKiT Inspection Request7/9/2026 9:15:43 AM 7/9/2026 9:15 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com

 07/10/2026TRAC:ILC REVIEWBUILDING COUNTERNOT APPROVEDeTRAKiT Inspection Request7/9/2026 2:59:43 PM 7/9/2026 2:59 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 7/10/2026 10:16:45 AM AVA26-0002 DENIED/NEED PLAT AMENDMENT

 07/13/2026TRAC: FINAL DOC REVIEWBUILDING COUNTERNOT APPROVEDeTRAKiT Inspection Request7/9/2026 2:59:43 PM 7/9/2026 2:59 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 7/13/2026 8:14:12 AM Need ILC and grade certificate approved.

 09/25/2026TRAC: FINAL DOC REVIEWBUILDING COUNTERNOT APPROVEDeTRAKiT Inspection Request9/24/2026 11:34:26 AM 9/24/2026 11:34 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 9/25/2026 9:48:35 AM final desc final grade CNA

 09/25/2026TRAC:ILC REVIEWBUILDING COUNTERAPPROVEDeTRAKiT Inspection Request9/24/2026 11:34:27 AM 9/24/2026 11:34 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 9/25/2026 8:48:42 AM Need new ILC

 09/28/2026D:REQ GRADE CERT REVJOHN GRAHNNOT APPROVEDSee notes on GC9/25/2026 1:45:12 PM 9/25/2026 1:45 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com

 09/28/2026D:FINAL DESCJOHN GRAHNNOT APPROVEDeTRAKiT Inspection Request9/25/2026 1:44:32 PM 9/25/2026 1:44 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 9/28/2026 1:24:01 PM Missing sediment control, log underneath downspouts and in drainage swales. Repair erosions through out the front and rear lot. Silt Fence in rear of lot pushed over with sediment. Remove the sediment and install reinforced SF to hold back sediment runoff coming off of the lot.

 09/29/2026D:REQ GRADE CERT REVJOHN GRAHNNOT APPROVEDRevise GC

 09/30/2026D:REQ GRADE CERT REVJOHN GRAHNNOT APPROVEDRevise GC

 10/01/2026D:REQ GRADE CERT REVJOHN GRAHNNOT APPROVEDRevise GC

D:REQ GRADE CERT REVSTORMWATER INSPECTORVOIDED (JOGR 10/1/2026)10/1/2026 7:37:12 AM Inspection voided by JOGR.

 10/07/2026D:REQ GRADE CERT REVJOHN GRAHNNOT APPROVEDeTRAKiT Inspection Request10/6/2026 11:31:05 AM 10/6/2026 11:31 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com

 10/08/2026D:FINAL DESCJOHN GRAHNAPPROVEDeTRAKiT Inspection Request10/6/2026 11:31:05 AM 10/6/2026 11:31 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com

 10/08/2026D:REQ GRADE CERT REVJOHN GRAHNAPPROVED

TRAC:FINAL BUILDINGTRACT INSPECTOR BeTRAKiT Inspection Request10/9/2026 8:58:25 AM 10/9/2026 8:58 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com

 10/09/2026TRAC: FINAL DOC REVIEWBUILDING COUNTERAPPROVEDCB10/8/2026 12:28:28 PM 10/8/2026 12:28 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com

TRAC:FINAL ELECTRICALTRACT INSPECTOR BeTRAKiT Inspection Request10/9/2026 8:58:26 AM 10/9/2026 8:58 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com

 10/13/2026TRAC:FINAL BUILDINGCOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request10/9/2026 9:02:18 AM 10/9/2026 9:02 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 10/13/2026 3:11:54 PM 1. Seal around gas meter 2. Seal around ac line set 3. 11th spindle at the rear stairs is loose 4. Paint pvc at sump pump exterior 5. Furnace intake needs a screen and exhaust needs a seal 6. Irrigation line is not complete 7. Fireplace inoperable 8. No ladder at attic access 9. Bathroom window is not tempered at the operable window 10. East deck railing top piece needs to be secured 11. Kitchen sink inoperable 12. Exposed floor joist lvls in the mechanical room ceiling next to the furnace

TRAC:RE-FINAL BUILDINGTRACT INSPECTOR BeTRAKiT Inspection Request10/16/2026 8:02:43 AM 10/16/2026 8:02 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com

 10/13/2026TRAC:FINAL ELECTRICALVINCE RAPONENOT APPROVEDeTRAKiT Inspection Request10/9/2026 9:02:18 AM 10/9/2026 9:02 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 10/13/2026 10:25:16 AM Need emergency disconnect labels on exterior service disconnects Support service feed within 3' of disconnect Hot / neutral reversed receptacles at front door and hallway ( see photo ) Microwave j box is loose Missing switch at master patio? Not sure if there was one there at rough Receptacle backside of wet bar needs gfci protection Kitchen receptacles need arc fault and gfci protection ( see breaker at panel ) breaker Label smokes in panel Reschedule final electrical

TRAC:RE-FINAL ELECTRICALTRACT INSPECTOR BeTRAKiT Inspection Request10/16/2026 8:02:43 AM 10/16/2026 8:02 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com

 10/30/2026TRAC:RE-FINAL BUILDINGSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request10/29/2026 11:06:36 AM 10/29/2026 11:06 AM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 10/30/2026 10:11:23 AM Final building inspection not approved 1. East side of deck railing loose 2. Furnace intake missing screen exterior 3. Missing smoke detectors label in panel 4. Microwave receptacle box is loose 5. Master bedroom patio door missing switch verify if this was installed that rough or not. 6. 8th stair baluster loose on stairs west side Recall final building when ready

 11/03/2026TRAC:RE-FINAL BUILDINGVINCE RAPONEAPPROVED FOR COeTRAKiT Inspection Request11/2/2026 2:32:34 PM 11/2/2026 2:32 PM Kevin Oler Contact Name: Kevin Oler Site Address: 5725 PLEASANT VIEW DR Phone: 3034348228 e-Mail: kevin.oler@shus.com 11/3/2026 11:09:44 AM Final building approved