11/21/2026
10:44 PM
 
Permit No. 25-4768 Permit Type   COMMERCIAL NEW Site Address   437 FIFER ST
CASTLE ROCK, CO 80109
Applied   12/31/2025 Applicant   CONFLUENCE BUILDERS LLC
Approved   08/07/2026 Owner   CD ACME LLC
Issued   08/07/2026 Contractor  
Parent Permit No.   Description   WEATHERFORD HALL & SAWTOOTH CORE AND SHELL BUILDING 1
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

PRE CON INSPECTIONBRETT LONGNECKER

 08/10/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALCall Brian at 914-924-89438/7/2026 9:28:44 AM 8/7/2026 9:28 AM CONFLUENCE BUILDERS LLC Underground plumbing inspection Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 8/10/2026 12:27:47 PM Under ground drains to grease trap. K through 2' passed D, on 8. In the Sawtooth buildingOn top plans the permit book. Marked in green.

 08/19/2026B:GROUND PLUMBINGMARTIN MAGERSCANCELCall Brian w/ Confluence - 914-924-89438/18/2026 1:49:49 PM 8/18/2026 1:49 PM CONFLUENCE BUILDERS LLC Underground plumbing partial Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 8/19/2026 8:27:35 AM NOT READY

 08/20/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALCall Brian w/ Confluence 914-924-89438/19/2026 8:29:29 AM 8/19/2026 8:29 AM CONFLUENCE BUILDERS LLC Underground plumbing partial Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 8/21/2026 7:03:48 AM Ground plumbing for 4" drain at SE corner to grid line 6., all underground DWV to grease trap up to just before the west wall of the service room. All marked in green along with the 8/10/26 ground plumbing inspection when the city approved plans were not on site.

B:ROUGH FRAMEBRETT LONGNECKERCall Cameron w/ Confluence 970-846-19699/17/2026 3:21:41 PM 9/17/2026 3:21 PM CONFLUENCE BUILDERS LLC Foundation wall damproofing and insulation Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com

 09/18/2026B:UFERSHAWN VALENZUELAAPPROVEDCall Cameron w/ Confluence 970-846-19699/17/2026 12:59:43 PM 9/17/2026 12:59 PM CONFLUENCE BUILDERS LLC UFER ground bar inspection Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 9/18/2026 9:30:01 AM Ufer inspection approved

 10/05/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALCall Brian w/ Confluence 914-924-894310/2/2026 12:53:02 PM 10/2/2026 12:53 PM CONFLUENCE BUILDERS LLC Plumbing underground partial Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 10/5/2026 11:10:00 AM Moved inspections from 8/10/26 and 8/19/26 on to town approved plans. Inspected 4" drain with 3 Stacks and 1 clean out as marked in pink on P-201 B 3-7.

 10/07/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALCall Brian w/ Confluence 914-924-894310/6/2026 12:52:57 PM 10/6/2026 12:52 PM CONFLUENCE BUILDERS LLC Partial plumbing underground Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 10/7/2026 9:55:41 AM Under ground grease line B 3-6. Marked in yellow on P-201.

 10/08/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALCall Brian w/ Confluence @ 914-924-894310/7/2026 10:09:59 AM 10/7/2026 10:09 AM CONFLUENCE BUILDERS LLC Partial plumbing underground Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 10/8/2026 12:58:13 PM Bath group for restaurant 101 approved as moved. Please submit revised plan. Marked in green on P 201.

 10/09/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALCall Brian w/ Confluence @ 914-924-894310/8/2026 12:37:44 PM 10/8/2026 12:37 PM CONFLUENCE BUILDERS LLC Partial plumbing underground Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 10/9/2026 12:16:59 PM Storm drain for weatherford hall side approved.

 10/13/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALCall Brian w/ Confluence 914-924-894310/12/2026 12:20:52 PM 10/12/2026 12:20 PM CONFLUENCE BUILDERS LLC Partial underground electrical conduit Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 10/13/2026 12:45:40 PM Mdp to - Panel K1 B1 - 3 - 3" pvc Panel K1B2 - 2 - 3-1/2" pvc Approved see one line page E002

 10/14/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALCall Brian w/ Confluence 914-924-894310/13/2026 8:24:13 PM 10/13/2026 8:24 PM CONFLUENCE BUILDERS LLC Electrical rough for patio wall lights Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 10/14/2026 2:32:36 PM 16 - Step lights for patio approved

 10/19/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALCall Brian w/ Confluence 914-924-894310/16/2026 9:50:25 AM 10/16/2026 9:50 AM CONFLUENCE BUILDERS LLC Partial underground plumbing Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 10/19/2026 10:32:17 AM Grease 4" , marked in Yellow and Storm 4", marked in orange, between sawtooth and weatherford hall . P201

 10/26/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALCall Brian w/ Confluence 914-924-894310/23/2026 12:21:53 PM 10/23/2026 12:21 PM CONFLUENCE BUILDERS LLC Partial underground plumbing Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 10/26/2026 4:03:39 PM 4" grease run with 4 stacks on P201 D through K marked in Yellow.

 10/29/2026B:GROUND PLUMBINGBRETT LONGNECKERPARTIALCall Brian w/ Confluence @ 914-924-894310/28/2026 4:24:58 PM 10/28/2026 4:24 PM CONFLUENCE BUILDERS LLC Partial underground Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 10/29/2026 4:55:34 PM Underground storm drains ok as highlighted in blue on town approved plans.

 11/04/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALCall Brian w/ Confluence 914-924-894311/3/2026 1:36:35 PM 11/3/2026 1:36 PM CONFLUENCE BUILDERS LLC Partial plumbing underground Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 11/4/2026 3:06:46 PM Sanitary DWV as marked in orange on P-201, approved.

 11/05/2026B:GROUND PLUMBINGMARTIN MAGERSAPPROVEDCall Brian w/ Confluence 914-924-894311/4/2026 12:01:44 PM 11/4/2026 12:01 PM CONFLUENCE BUILDERS LLC Partial plumbing underground Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 11/5/2026 10:51:28 AM 6" foot sink approved. All underground plumbing complete.

 11/06/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALCall Brian w/ Confluence 914-924-894311/5/2026 12:30:14 PM 11/5/2026 12:30 PM CONFLUENCE BUILDERS LLC Electrical underground conduit Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 11/6/2026 10:39:11 AM Under ground at MSDS only Msds 1 to transformer - 8 - 3-1/2 pvc Msds 2 to transformer - 8 - 3-1/2 pvc Msds 1 to L3A M3A 2LA

 11/10/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALunderground rough electrical11/9/2026 4:57:23 PM 11/9/2026 4:57 PM CONFLUENCE BUILDERS LLC Partial electrical underground Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 11/10/2026 10:47:40 AM Panel stub from msds1 underground rough electrical approved K1A1 K1A2 Panel stubs from msds2 underground rough electrical approved L2B L1B M3B L3B 11/10/2026 10:50:38 AM Panel stub from msds1 underground rough electrical approved K1A1 K1A2 Panel stubs from msds2 underground rough electrical approved L2B L1B M3B L3B

 11/13/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALunderground electrical rough11/12/2026 1:37:43 PM 11/12/2026 1:37 PM CONFLUENCE BUILDERS LLC Partial underground electrical conduit Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 11/13/2026 11:59:01 AM 1 - 1-1/2 bda stubbed tech room 105 3 - 4" data sleeves stubbed to tech room Panel L1A and L1C fed from mds 1 L1B fed From mds 2 stubbed up at tech room K1A2 - 2 - 4" K1 A1 - 3 - 3"

 11/19/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALunderground rough electrical11/18/2026 12:21:02 PM 11/18/2026 12:21 PM CONFLUENCE BUILDERS LLC Partial electrical underground Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 11/19/2026 9:43:13 AM k1A1 - 3 - 3" from mds1 to future tenant space

 11/20/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALCall Brian w/ Confluence at 914-924-894311/19/2026 3:28:50 PM 11/19/2026 3:28 PM CONFLUENCE BUILDERS LLC Partial underground electric Contact Name: CONFLUENCE BUILDERS LLC Site Address: 437 FIFER ST Phone: 9149248943 e-Mail: brian@confluenceco.com 11/20/2026 12:31:38 PM 16 - 3-1/2" pvc from mds1&2 to end of property line ( still need to transformer ) 8 go to mds1 9 go to mds2