| 02/27/2026 | R:ELEC CONSTR MTR | SHAWN VALENZUELA | NOT APPROVED | Please inspect temp meter | 2/26/2026 2:05:23 PM
2/26/2026 2:05 PM COLORADO MOUNTAIN ELECTRIC INC
Contact Name: COLORADO MOUNTAIN ELECTRIC INC
Site Address: 5071 LIONS PAW ST
Phone: 3037395798
e-Mail: AARON.SMITH@COLORADOME.COM
2/27/2026 10:33:19 AM
Construction meter not approved
Handle tie for 2 pull breaker damage (see photo)
Both gfi receptacles ground ports are damaged ( see photo)
|
|
| 02/27/2026 | R:ELEC CONSTR MTR | SHAWN VALENZUELA | CANCEL | eTRAKiT Inspection Request | 2/26/2026 1:18:13 PM
2/26/2026 1:18 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
2/27/2026 10:36:35 AM
Duplicate inspections were called in
|
|
| 03/02/2026 | R:ELEC CONSTR MTR | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 2/27/2026 12:24:57 PM
2/27/2026 12:24 PM COLORADO MOUNTAIN ELECTRIC INC
Contact Name: COLORADO MOUNTAIN ELECTRIC INC
Site Address: 5071 LIONS PAW ST
Phone: 3037395798
e-Mail: AARON.SMITH@COLORADOME.COM
3/2/2026 10:52:00 AM
Construction meter approved
|
|
| 04/06/2026 | R:GRND PLUMBING | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 4/3/2026 9:09:54 AM
4/3/2026 9:09 AM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
4/6/2026 2:49:15 PM
APPROVED-
NOTE: 1/2" COPPER PIPE PENETRATION AT EAST FOUNDATION WALL SEALED FROM INSIDE, UNABLE TO VERIFY EXTERIOR DUE TO BACK FILL.
NO OTHER PENETRATIONS AT TIME OF GRND PLUMBING INSPECTION.
|
|
| 04/07/2026 | R:ELECTRICAL UNDERGR | SHAWN VALENZUELA | APPROVED | conduit in basement | 4/6/2026 4:05:36 PM
Bob 7206285215
4/7/2026 11:27:05 AM
Electrical underground approved
Notes.
3 under ground floor outlets in basement 1. north wall of basement 2. Stub up in fire place location jumped together (see photo)
|
|
| 05/13/2026 | R:WALL BRACING | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 5/12/2026 9:45:26 AM
5/12/2026 9:45 AM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
5/13/2026 1:29:18 PM
APPROVED.
|
|
| 06/09/2026 | R:WTHR RESIS BARRIER | COLBY RIGGINS | NOT APPROVED | eTRAKiT Inspection Request | 6/8/2026 2:39:44 PM
6/8/2026 2:39 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
6/9/2026 12:27:17 PM
1. Front south side below the window has four vertical pieces that need tape.
2. Missing basement south window and not covered
3. Second story in the rear at the deck cover south side needs tape at vertical cut
Please have something labeling the address for this house.
Ok to release water meter.
|
|
| 06/12/2026 | R:WTHR RESIS BARRIER | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 6/11/2026 3:10:43 PM
6/11/2026 3:10 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
6/12/2026 1:59:48 PM
APPROVED.
NOTE: NO INSPECTION CARD ON SITE.
|
|
| 07/16/2026 | R:ROUGH FRAME | COLBY RIGGINS | PARTIAL | eTRAKiT Inspection Request | 7/15/2026 2:42:07 PM
7/15/2026 2:42 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
7/16/2026 1:22:28 PM
Ceilings ok with h2.5 as needed and blocking.
|
|
| 07/17/2026 | R:ELEC TRENCHES | SHAWN VALENZUELA | APPROVED | eTRAKiT Inspection Request | 7/16/2026 2:49:48 PM
7/16/2026 2:49 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
7/17/2026 10:49:07 AM
Electrical trench inspection approved
2 sets of 4/0 AWG with 4 AWG ground
Direct burial cable coming from main disconnect at street side to sub panels at house right side of exterior front door
|
|
| 07/21/2026 | R:LATH_STONE_BRICK | SHAWN VALENZUELA | NOT APPROVED | eTRAKiT Inspection Request | 7/20/2026 12:58:29 PM
7/20/2026 12:58 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
7/21/2026 10:03:57 AM
Lath and stone inspection not approved
1. No plans on site, have plans showing exterior elevations for next inspection
Reschedule inspection when corrections are completed
|
|
| 07/23/2026 | R:LATH_STONE_BRICK | SHAWN VALENZUELA | PARTIAL | eTRAKiT Inspection Request | 7/22/2026 12:42:01 PM
7/22/2026 12:42 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
7/23/2026 10:10:08 AM
Lath inspection partial inspection approved
Brick tie inspection front entry door way area, back fire wall area.
|
|
| 08/12/2026 | R:ROUGH FRAME | MARTIN MAGERS | PARTIAL | eTRAKiT Inspection Request | 8/10/2026 2:57:21 PM
8/10/2026 2:57 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
8/12/2026 12:00:37 PM
Rough Mechanical approved.
All steel framing inspected by third party, engineer letter approved.
No structural plans on site.
No plumbing or gas on site,
8/12/2026 1:38:27 PM
Rough Mechanical approved.
All steel framing inspected by third party, engineer letter approved.
No structural plans on site.
No plumbing or gas on site,
8/12/2026 2:09:15 PM
Rough Mechanical approved.
All steel framing inspected by third party, engineer letter approved.
No structural plans on site.
No plumbing or gas on site,
|
|
| R:ROUGH DECK | MICHAEL RANKIN | | eTRAKiT Inspection Request | 8/12/2026 7:54:31 AM
8/12/2026 7:54 AM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
|
|
| 08/13/2026 | R:ROUGH ELECTRICAL | VINCE RAPONE | APPROVED | | 8/13/2026 12:59:29 PM
Rough electrical approved
|
|
| 08/13/2026 | R:ROUGH FRAME | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 8/12/2026 12:48:07 PM
8/12/2026 12:48 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
8/13/2026 1:45:07 PM
NOT APPROVED-
1) MISSING SQUARE WASHERS AT GARAGE PORTAL FRAME.
2) MISSING CORRECT 1/3 EMBEDMENT AT SOLE PLATE FOR ANCHOR BOLTS IN MAIN FLOOR BEDROOM TWO , SOUTH WALL.
3) MISSING FIRE-BLOCKING AT DOUBLE TOP PLATE FOR MEDIA PENETRATION/ MASTER BATH SHOWER.
****4) CRAWL SPACE FRAMING TO BE CHECKED AT FUTURE INSPECTION.
NOTE: NEED VERIFICATION FROM A COLORADO DESIGN PROFESSIONAL FOR TOP BASEMENT STAIR CONNECTION.
CRAWL SPACE / FINISHED WALK-OUT BASEMENT/ REAR LID & DECK.
|
|
| 08/13/2026 | R:PORCH POST REAR | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 8/12/2026 7:54:32 AM
8/12/2026 7:54 AM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
8/13/2026 1:45:10 PM
RE- CALL FRONT AND REAR POST INSPECTION WITH RE RGH FRAME.
|
|
| 08/13/2026 | R:PORCH POST FRONT | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 8/12/2026 7:54:31 AM
8/12/2026 7:54 AM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
8/13/2026 1:45:12 PM
NOT APPROVED-
RE- CALL FRONT AND REAR POST INSPECTION WITH RE RGH FRAME.
|
|
| 08/14/2026 | R:PORCH POST REAR | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 8/13/2026 12:53:17 PM
8/13/2026 12:53 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
8/14/2026 7:50:08 AM
Inspector JOCA changed the inspection assignment from JOCA to MAM2
|
|
| 08/14/2026 | R:PORCH POST FRONT | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 8/13/2026 12:53:16 PM
8/13/2026 12:53 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
8/14/2026 7:51:04 AM
Inspector JOCA changed the inspection assignment from JOCA to MAM2
|
|
| 08/14/2026 | R:ROUGH FRAME | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 8/13/2026 12:39:01 PM
8/13/2026 12:39 PM WYMAC ENTERPRISES INC
for bedroom #2 foundation bolts and square washers at portal fram
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
8/14/2026 10:28:21 AM
APPROVED-
1) UPLOAD VERIFICATION FROM A COLORADO DESIGN PROFESSIONAL FOR TOP BASEMENT STAIR CONNECTION BEFORE FINAL.
|
|
| 08/19/2026 | R:INSULATION | SHAWN VALENZUELA | NOT APPROVED | eTRAKiT Inspection Request | 8/18/2026 1:04:35 PM
8/18/2026 1:04 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
8/19/2026 2:26:13 PM
Insulation inspection not approved
1. Upload ESR report for spray foam insulation installed above Bat insulation.
Reschedule and corrections are complete completed
|
|
| 08/20/2026 | R:INSULATION | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 8/19/2026 2:20:39 PM
8/19/2026 2:20 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
8/20/2026 11:50:06 AM
APPROVED.
|
|
| 09/01/2026 | R:SHEAR WALL_DRYWALL | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 8/31/2026 2:58:12 PM
8/31/2026 2:58 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
9/1/2026 1:45:09 PM
Approved
|
|
| 09/04/2026 | R:ROUGH DECK | JOE CARBAUGH | NOT APPROVED | eTRAKiT Inspection Request | 9/3/2026 3:20:29 PM
9/3/2026 3:20 PM WYMAC ENTERPRISES INC
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
9/4/2026 1:24:48 PM
NOT APPROVED-
1) AS BUILT CONDITION DOES NOT MATCH STAMPED PLANS PER (SD1 8 DECK ATTACHMENT TO WOOD FLOOR) / ( DECK JOISTS) CONNECTION TO WEST BEAM.
|
|
| 09/16/2026 | R:ROUGH DECK | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 9/15/2026 9:59:26 AM
9/15/2026 9:59 AM WYMAC ENTERPRISES INC
Engineer Letter with card
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
9/16/2026 12:38:00 PM
APPROVED.
|
|
| 09/16/2026 | R:LATH_STONE_BRICK | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 9/15/2026 9:58:32 AM
9/15/2026 9:58 AM WYMAC ENTERPRISES INC
Stucco
Contact Name: WYMAC ENTERPRISES INC
Site Address: 5071 LIONS PAW ST
Phone: 7207469240
e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM
9/16/2026 12:38:02 PM
APPROVED. ( STUCCO) PORTION.
|
|
| 11/03/2026 | U: METER SET | GRANT TAYLOR | METER INSP FAIL 1 | | 11/3/2026 1:24:12 PM
A $50.00 re-inspection fee will be charged to the building permit. Once corrections have been made, please email your request for a re-inspection to meterset@crgov.com. Please note that we have up to four business days from the initial request to complete the re-inspection.
Curbstop needs to be visible and accessible upon arrival.
Mxu mount needs 8x8 frame with pex flushed.
Need main shutoff valve with in 1ft of water entry, also every 4ft of copper pipe requires additional ball valve.
|
|