Permit No. 25-3844 Permit Type   RESIDENTIAL CUSTOM Site Address   5071 LIONS PAW ST
CASTLE ROCK, CO 80104
Applied   10/13/2025 Applicant   WYMAC ENTERPRISES INC
Approved   02/10/2026 Owner   WORKSHOP-CVR LLC
Issued   02/17/2026 Contractor  
Parent Permit No.   Description   NEW SINGLE FAMILY DETACHED CUSTOM RESIDENCE - WALNUT
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 02/27/2026R:ELEC CONSTR MTRSHAWN VALENZUELANOT APPROVEDPlease inspect temp meter2/26/2026 2:05:23 PM 2/26/2026 2:05 PM COLORADO MOUNTAIN ELECTRIC INC Contact Name: COLORADO MOUNTAIN ELECTRIC INC Site Address: 5071 LIONS PAW ST Phone: 3037395798 e-Mail: AARON.SMITH@COLORADOME.COM 2/27/2026 10:33:19 AM Construction meter not approved Handle tie for 2 pull breaker damage (see photo) Both gfi receptacles ground ports are damaged ( see photo)

 02/27/2026R:ELEC CONSTR MTRSHAWN VALENZUELACANCELeTRAKiT Inspection Request2/26/2026 1:18:13 PM 2/26/2026 1:18 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 2/27/2026 10:36:35 AM Duplicate inspections were called in

 03/02/2026R:ELEC CONSTR MTRSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request2/27/2026 12:24:57 PM 2/27/2026 12:24 PM COLORADO MOUNTAIN ELECTRIC INC Contact Name: COLORADO MOUNTAIN ELECTRIC INC Site Address: 5071 LIONS PAW ST Phone: 3037395798 e-Mail: AARON.SMITH@COLORADOME.COM 3/2/2026 10:52:00 AM Construction meter approved

 04/06/2026R:GRND PLUMBINGJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request4/3/2026 9:09:54 AM 4/3/2026 9:09 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 4/6/2026 2:49:15 PM APPROVED- NOTE: 1/2" COPPER PIPE PENETRATION AT EAST FOUNDATION WALL SEALED FROM INSIDE, UNABLE TO VERIFY EXTERIOR DUE TO BACK FILL. NO OTHER PENETRATIONS AT TIME OF GRND PLUMBING INSPECTION.

 04/07/2026R:ELECTRICAL UNDERGRSHAWN VALENZUELAAPPROVEDconduit in basement4/6/2026 4:05:36 PM Bob 7206285215 4/7/2026 11:27:05 AM Electrical underground approved Notes. 3 under ground floor outlets in basement 1. north wall of basement 2. Stub up in fire place location jumped together (see photo)

 05/13/2026R:WALL BRACINGJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request5/12/2026 9:45:26 AM 5/12/2026 9:45 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 5/13/2026 1:29:18 PM APPROVED.

 06/09/2026R:WTHR RESIS BARRIERCOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request6/8/2026 2:39:44 PM 6/8/2026 2:39 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 6/9/2026 12:27:17 PM 1. Front south side below the window has four vertical pieces that need tape. 2. Missing basement south window and not covered 3. Second story in the rear at the deck cover south side needs tape at vertical cut Please have something labeling the address for this house. Ok to release water meter.

 06/12/2026R:WTHR RESIS BARRIERJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request6/11/2026 3:10:43 PM 6/11/2026 3:10 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 6/12/2026 1:59:48 PM APPROVED. NOTE: NO INSPECTION CARD ON SITE.

 07/16/2026R:ROUGH FRAMECOLBY RIGGINSPARTIALeTRAKiT Inspection Request7/15/2026 2:42:07 PM 7/15/2026 2:42 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 7/16/2026 1:22:28 PM Ceilings ok with h2.5 as needed and blocking.

 07/17/2026R:ELEC TRENCHESSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request7/16/2026 2:49:48 PM 7/16/2026 2:49 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 7/17/2026 10:49:07 AM Electrical trench inspection approved 2 sets of 4/0 AWG with 4 AWG ground Direct burial cable coming from main disconnect at street side to sub panels at house right side of exterior front door

 07/21/2026R:LATH_STONE_BRICKSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request7/20/2026 12:58:29 PM 7/20/2026 12:58 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 7/21/2026 10:03:57 AM Lath and stone inspection not approved 1. No plans on site, have plans showing exterior elevations for next inspection Reschedule inspection when corrections are completed

 07/23/2026R:LATH_STONE_BRICKSHAWN VALENZUELAPARTIALeTRAKiT Inspection Request7/22/2026 12:42:01 PM 7/22/2026 12:42 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 7/23/2026 10:10:08 AM Lath inspection partial inspection approved Brick tie inspection front entry door way area, back fire wall area.

 08/12/2026R:ROUGH FRAMEMARTIN MAGERSPARTIALeTRAKiT Inspection Request8/10/2026 2:57:21 PM 8/10/2026 2:57 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 8/12/2026 12:00:37 PM Rough Mechanical approved. All steel framing inspected by third party, engineer letter approved. No structural plans on site. No plumbing or gas on site, 8/12/2026 1:38:27 PM Rough Mechanical approved. All steel framing inspected by third party, engineer letter approved. No structural plans on site. No plumbing or gas on site, 8/12/2026 2:09:15 PM Rough Mechanical approved. All steel framing inspected by third party, engineer letter approved. No structural plans on site. No plumbing or gas on site,

R:ROUGH DECKMICHAEL RANKINeTRAKiT Inspection Request8/12/2026 7:54:31 AM 8/12/2026 7:54 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM

 08/13/2026R:ROUGH ELECTRICALVINCE RAPONEAPPROVED8/13/2026 12:59:29 PM Rough electrical approved

 08/13/2026R:ROUGH FRAMEJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request8/12/2026 12:48:07 PM 8/12/2026 12:48 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 8/13/2026 1:45:07 PM NOT APPROVED- 1) MISSING SQUARE WASHERS AT GARAGE PORTAL FRAME. 2) MISSING CORRECT 1/3 EMBEDMENT AT SOLE PLATE FOR ANCHOR BOLTS IN MAIN FLOOR BEDROOM TWO , SOUTH WALL. 3) MISSING FIRE-BLOCKING AT DOUBLE TOP PLATE FOR MEDIA PENETRATION/ MASTER BATH SHOWER. ****4) CRAWL SPACE FRAMING TO BE CHECKED AT FUTURE INSPECTION. NOTE: NEED VERIFICATION FROM A COLORADO DESIGN PROFESSIONAL FOR TOP BASEMENT STAIR CONNECTION. CRAWL SPACE / FINISHED WALK-OUT BASEMENT/ REAR LID & DECK.

 08/13/2026R:PORCH POST REARJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request8/12/2026 7:54:32 AM 8/12/2026 7:54 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 8/13/2026 1:45:10 PM RE- CALL FRONT AND REAR POST INSPECTION WITH RE RGH FRAME.

 08/13/2026R:PORCH POST FRONTJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request8/12/2026 7:54:31 AM 8/12/2026 7:54 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 8/13/2026 1:45:12 PM NOT APPROVED- RE- CALL FRONT AND REAR POST INSPECTION WITH RE RGH FRAME.

 08/14/2026R:PORCH POST REARMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request8/13/2026 12:53:17 PM 8/13/2026 12:53 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 8/14/2026 7:50:08 AM Inspector JOCA changed the inspection assignment from JOCA to MAM2

 08/14/2026R:PORCH POST FRONTMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request8/13/2026 12:53:16 PM 8/13/2026 12:53 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 8/14/2026 7:51:04 AM Inspector JOCA changed the inspection assignment from JOCA to MAM2

 08/14/2026R:ROUGH FRAMEJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request8/13/2026 12:39:01 PM 8/13/2026 12:39 PM WYMAC ENTERPRISES INC for bedroom #2 foundation bolts and square washers at portal fram Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 8/14/2026 10:28:21 AM APPROVED- 1) UPLOAD VERIFICATION FROM A COLORADO DESIGN PROFESSIONAL FOR TOP BASEMENT STAIR CONNECTION BEFORE FINAL.

 08/19/2026R:INSULATIONSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request8/18/2026 1:04:35 PM 8/18/2026 1:04 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 8/19/2026 2:26:13 PM Insulation inspection not approved 1. Upload ESR report for spray foam insulation installed above Bat insulation. Reschedule and corrections are complete completed

 08/20/2026R:INSULATIONJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request8/19/2026 2:20:39 PM 8/19/2026 2:20 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 8/20/2026 11:50:06 AM APPROVED.

 09/01/2026R:SHEAR WALL_DRYWALLCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request8/31/2026 2:58:12 PM 8/31/2026 2:58 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 9/1/2026 1:45:09 PM Approved

 09/04/2026R:ROUGH DECKJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request9/3/2026 3:20:29 PM 9/3/2026 3:20 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 9/4/2026 1:24:48 PM NOT APPROVED- 1) AS BUILT CONDITION DOES NOT MATCH STAMPED PLANS PER (SD1 8 DECK ATTACHMENT TO WOOD FLOOR) / ( DECK JOISTS) CONNECTION TO WEST BEAM.

 09/16/2026R:ROUGH DECKJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/15/2026 9:59:26 AM 9/15/2026 9:59 AM WYMAC ENTERPRISES INC Engineer Letter with card Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 9/16/2026 12:38:00 PM APPROVED.

 09/16/2026R:LATH_STONE_BRICKJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request9/15/2026 9:58:32 AM 9/15/2026 9:58 AM WYMAC ENTERPRISES INC Stucco Contact Name: WYMAC ENTERPRISES INC Site Address: 5071 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 9/16/2026 12:38:02 PM APPROVED. ( STUCCO) PORTION.

 11/03/2026U: METER SETGRANT TAYLORMETER INSP FAIL 111/3/2026 1:24:12 PM A $50.00 re-inspection fee will be charged to the building permit. Once corrections have been made, please email your request for a re-inspection to meterset@crgov.com. Please note that we have up to four business days from the initial request to complete the re-inspection. Curbstop needs to be visible and accessible upon arrival. Mxu mount needs 8x8 frame with pex flushed. Need main shutoff valve with in 1ft of water entry, also every 4ft of copper pipe requires additional ball valve.