11/21/2026
10:44 PM
 
Permit No. 25-3423 Permit Type   RESIDENTIAL CUSTOM Site Address   5157 LIONS PAW ST
CASTLE ROCK, CO 80104
Applied   09/12/2025 Applicant   WYMAC ENTERPRISES INC
Approved   12/19/2025 Owner   WYMAC ENTERPRISES INC
Issued   12/22/2025 Contractor  
Parent Permit No.   Description   NEW SINGLE FAMILY DETACHED CUSTOM RESIDENCE
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 01/08/2026R:ELEC CONSTR MTRSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request1/7/2026 12:46:06 PM 1/7/2026 12:46 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 1/8/2026 1:23:37 PM No ground rods allowed per core electric (see photo) note 3 No inspection card on site Reschedule when ready

 01/13/2026R:ELEC CONSTR MTRSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request1/12/2026 10:36:58 AM 1/12/2026 10:36 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 1/13/2026 12:32:54 PM Construction meter good

 02/09/2026R:GRND PLUMBINGJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request2/6/2026 10:18:12 AM 2/6/2026 10:18 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 2/9/2026 2:21:50 PM APPROVED.

 03/23/2026R:WALL BRACINGJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request3/20/2026 3:01:56 PM 3/20/2026 3:01 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 3/23/2026 1:57:18 PM NOT APPROVED. NO FRAMING OR SHEAR PLANS ON SITE. NOTE PLEASE RECALL WHEN PLANS ARE ON SITE.

 03/24/2026R:WALL BRACINGJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request3/23/2026 1:22:40 PM 3/23/2026 1:22 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 3/24/2026 2:55:10 PM PARTIAL- EXTERIOR WALL BRACING - OK NOTE: DETAIL 13 FOR WINDOW SHEAR OPENING HORIZONTAL CS ON (INSIDE) TO BE CHECKED AT ROUGH FRAME.

 04/02/2026R:WTHR RESIS BARRIERSHAWN VALENZUELANOT APPROVEDeTRAKiT Inspection Request4/1/2026 2:28:41 PM 4/1/2026 2:28 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 4/2/2026 9:28:04 AM Weather resistant barrier inspection not approved Weather resistant barriers incomplete in several locations Please recall inspection when work is completed

 04/03/2026R:WTHR RESIS BARRIERSHAWN VALENZUELAAPPROVEDeTRAKiT Inspection Request4/2/2026 1:58:26 PM 4/2/2026 1:58 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 4/3/2026 10:24:37 AM Weather resistive barrier approved

 04/14/2026R:ELEC TRENCHESSHAWN VALENZUELAPARTIALeTRAKiT Inspection Request4/13/2026 8:58:15 AM 4/13/2026 8:58 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 4/14/2026 10:14:51 AM Electrical trenches partial approved to back fill 2 200 amp service laterals direct burial cable come from core meter pedestal Notes. Please install direct burial tape 12 to 18 inches above direct burial cable when back filling has started At time of inspection direct burial cables are not installed in pvc terminating inside the house/ meter pedestal please call in another inspection before these portions are backfilled.

 05/04/2026R:LATH_STONE_BRICKJOE CARBAUGHPARTIALeTRAKiT Inspection Request5/1/2026 11:56:10 AM 5/1/2026 11:56 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 5/1/2026 11:59:01 AM 5/1/2026 11:59 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 5/4/2026 2:25:11 PM PARTIAL - INSPECTION WAS - OK FOR BRICK , LATH INSPECTION FOR STUCCO TO BE LOOKED AT FUTURE INSPECTION.

 06/25/2026R:ROUGH ELECTRICALVINCE RAPONEAPPROVEDeTRAKiT Inspection Request6/24/2026 11:50:25 AM 6/24/2026 11:50 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 6/25/2026 11:08:41 AM Rough electrical approved Note - receptacles on backside of a island cannot serve countertop. Need to be lower serving the living room. Will check at final

 06/25/2026R:ROUGH FRAMEJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request6/24/2026 11:50:25 AM 6/24/2026 11:50 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 6/25/2026 1:21:50 PM NOT APPROVED- 1) STEEL MONO POST NOT FULL BEARING/ FRONT OF GARAGES BETWEEN SINGLE & TWO CAR GARAGE. 2) MISSING CS STRAP 48" FROM START OF WALL/ MAIN LEVEL BEDROOM FIVE BATHROOM LEFT WALL. 3) MISSING METAL PLATES FOR PLUMBING STUD PENETRATION / MATER BATH WEST WALL. 4) MISSING MINIMUM 2" VERTICAL SPACE FOR PLUMBING PENETRATION THROUGH BOTTOM HALF OF FLOOR JOIST/ LAUNDRY ROOM. 5) STEEL MONO POST NOT FULL BEARING / REAR DECK, CENTER POST BASE. REST OF FRAME - OK. GAS ON TEST -OK. RGH PLUMBING- OK. RGH MECHANICAL- OK. ISO- FURNACE 2nd FURNACE GREAT ROOM FIREPLACE BASEMENT FIREPLACE DRYER REAR BBQ NOTE: LETTERS TO BE SUBMITTED & ON SITE BY FINAL BUILDING INSPECTION. FINISHED BASEMENT/ PARTIAL CRAWL SPACE/ REAR DECK.

 06/25/2026R:PORCH POST REARJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request6/24/2026 11:50:25 AM 6/24/2026 11:50 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 6/25/2026 1:21:54 PM APPROVED.

 06/25/2026R:PORCH POST FRONTJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request6/24/2026 11:46:47 AM 6/24/2026 11:46 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 6/25/2026 1:21:59 PM APPROVED

 06/25/2026B:WALL BRACINGJOE CARBAUGHAPPROVED6/25/2026 1:22:31 PM APPROVED- 1) CONFIRMED, STAMPED OBSERVATION LETTER FOR WALL BRACING/ PLANS ON SITE.

 06/29/2026R:ROUGH FRAMEJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request6/26/2026 11:10:12 AM 6/26/2026 11:10 AM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 6/29/2026 2:55:24 PM APPROVED. NOTE: CHECK STEEL MONO POST IN GARAGE & STAMPED REPAIR LETTER AT BUILDING FINAL.

 07/08/2026R:INSULATIONCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request7/7/2026 12:00:25 PM 7/7/2026 12:00 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 7/8/2026 12:54:16 PM Approved

 07/28/2026R:SHEAR WALL_DRYWALLCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request7/27/2026 2:29:16 PM 7/27/2026 2:29 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM 7/28/2026 2:52:58 PM Approved

 08/12/2026R:LATH_STONE_BRICKMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request8/11/2026 12:56:37 PM 8/11/2026 12:56 PM WYMAC ENTERPRISES INC Contact Name: WYMAC ENTERPRISES INC Site Address: 5157 LIONS PAW ST Phone: 7207469240 e-Mail: ENTITLEMENTS@WORKSHOP-COLORADO.COM

 11/03/2026U: METER SETGRANT TAYLORMETER INSP FAIL 111/3/2026 1:24:09 PM A $50.00 re-inspection fee will be charged to the building permit. Once corrections have been made, please email your request for a re-inspection to meterset@crgov.com. Please note that we have up to four business days from the initial request to complete the re-inspection. Curbstop lid spins with box, curbstop not functional. Pex needs to be flushed with Mxu mount. Need copper pipe instead of pex up to the "T" also need shutoff valve with in 1ft of water entry, also every 4ft of copper pipe requires additional ball valve.