| 07/15/2025 | R:CAISSONS | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 7/14/2025 11:04:35 AM
7/14/2025 11:04 AM TIMBER DESIGNS LLC
Contact Name: TIMBER DESIGNS LLC
Site Address: 3667 SUNCHASE DR
Phone: 3035063354
e-Mail: TIMBERDESIGNS3@GMAIL.COM
7/15/2025 2:22:48 PM
1. Caissons must have steel drilled into them, as required by plans. Also, must be properly sized, corner 18x18 square and the next one 24x 24 square. And a full 3 ft deep.
|
|
| 07/23/2025 | R:CAISSONS | ADAM KINDLE | APPROVED | eTRAKiT Inspection Request | 7/22/2025 2:20:56 PM
7/22/2025 2:20 PM TIMBER DESIGNS LLC
please call when on your way 303-506-3354
Contact Name: TIMBER DESIGNS LLC
Site Address: 3667 SUNCHASE DR
Phone: 3035063354
e-Mail: TIMBERDESIGNS3@GMAIL.COM
7/23/2025 2:03:21 PM
Approved
have caissons clear before pouring new one
|
|
| 08/12/2025 | R:FNL BUILDING | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 8/11/2025 1:43:43 PM
8/11/2025 1:43 PM TIMBER DESIGNS LLC
Contact Name: TIMBER DESIGNS LLC
Site Address: 3667 SUNCHASE DR
Phone: 3035063354
e-Mail: TIMBERDESIGNS3@GMAIL.COM
8/12/2025 1:34:32 PM
No rough inspection was called in on this deck.
1. Plans not show support by the cantilever of the house. iIf you want to keep it this way you will need to get an engineers letter approving of current design or extend joists be supported by the main wall of the house.
2. Missing lateral support.
3. AC6 post caps are required to be on both side of the beam. Will except comparable hardware.
4. Missing nails ft joist hangers at 8 locations. Where they are 6 in separations.
5. Moldy siding was used to replace siding under the ledger.
6. Stair strings not fully seated at bottom landing. If shimming, please secure the shims.
|
|
| 09/24/2026 | R:FNL BUILDING | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 9/23/2026 4:05:43 PM
9/23/2026 4:05 PM TIMBER DESIGNS LLC
Contact Name: TIMBER DESIGNS LLC
Site Address: 3667 SUNCHASE DR
Phone: 3035063354
e-Mail: TIMBERDESIGNS3@GMAIL.COM
9/24/2026 12:02:33 PM
Missing lateral bracing.
|
|
| 10/22/2026 | R:FNL BUILDING | MARTIN MAGERS | APPROVED | Please call when on the way 303-506-3354 | 10/21/2026 11:22:27 AM
10/21/2026 11:22 AM TIMBER DESIGNS LLC
Contact Name: TIMBER DESIGNS LLC
Site Address: 3667 SUNCHASE DR
Phone: 3035063354
e-Mail: TIMBERDESIGNS3@GMAIL.COM
10/26/2026 8:57:46 AM
Corrections made. Rough Frame approved as well
|
|