Permit No. 25-1336 Permit Type   COMMERCIAL NEW Site Address   444 FIFER ST
CASTLE ROCK, CO 80109
Applied   04/18/2025 Applicant   eric blase - Studio 646 Architecture
Approved   02/20/2026 Owner   BRICKYARD APARTMENTS SPE LLC
Issued   11/25/2025 Contractor  
Parent Permit No.   Description   BRICKYARD BUILDING 5
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 12/15/2025B:UNGRD PLUMBBRETT LONGNECKERNOT APPROVEDeTRAKiT Inspection Request12/10/2025 3:26:11 PM 12/10/2025 3:26 PM UMC INC Sand/Oil Tank Contact Name: UMC INC Site Address: NOT ASSIGNED BRICKYARD BLDG 5 Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 12/15/2025 8:10:32 AM Nate 7204034162 12/15/2025 9:15:18 AM Consult for inspection sequence of sand/oil waste interceptor. Schedule inspection with PCWRA for inspection of interceptor. Schedule Town for inspection of all plumbing to interceptor.

 12/18/2025B:UNGRD PLUMBBRETT LONGNECKERPARTIALsand oil waste interceptor cleanouts.12/17/2025 11:06:32 AM UNDERGROUND SAND OIL TANK NATHAN 7204034162 12/18/2025 6:33:24 AM Clean outs and piping into sand/ oil waste interceptor ok. Piping stubs out 8 ft from interceptor. Still need to inspect remain sand/oil waste piping throughout all parking areas.

 01/14/2026B:ELECTRICAL SERVICEVINCE RAPONEPARTIALeTRAKiT Inspection Request1/13/2026 8:40:27 AM 1/13/2026 8:40 AM Clyde George UFER inspection. Contact Name: Clyde George Site Address: NOT ASSIGNED BRICKYARD BLDG 5 Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 1/14/2026 2:44:26 PM Ufer stubbed into electrical room good

 01/16/2026B:UNGRD PLUMBMARTIN MAGERSPARTIALeTRAKiT Inspection Request1/15/2026 1:59:19 PM 1/15/2026 1:59 PM UMC INC grease interceptor in/out connections Contact Name: UMC INC Site Address: NOT ASSIGNED BRICKYARD BLDG 5 Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 1/16/2026 12:55:37 PM Grease pit with stub outs approved.

 02/05/2026B:UNGRD PLUMBBRETT LONGNECKERNOT APPROVEDCourtesy Inspection2/4/2026 1:46:37 PM 2/4/2026 1:46 PM UMC INC Courtesy insp- questions about sanitary and storm tie in outside building Contact Name: UMC INC Site Address: NOT ASSIGNED BRICKYARD BLDG 5 Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 2/5/2026 12:20:22 PM Courtesy inspection to discuss south side of building lower parking sanitary and storm drain connections outside of building. Ok to use 6 inch cleanouts for sanitary outside of building as long as civics do not call for 8 inch. Storm drain cleanouts inside building footing print can be used for clean out outside of building as long as any radiuses greater than 45 degrees are within 40 ft of that clean out.

 02/09/2026B:UNGRD PLUMBMARTIN MAGERSPARTIALsouth P1 san sewer2/6/2026 12:45:59 PM 2/6/2026 12:45 PM UMC INC Contact Name: UMC INC Site Address: NOT ASSIGNED BRICKYARD BLDG 5 Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 2/6/2026 1:04:07 PM 2/6/2026 1:04 PM UMC INC Contact Name: UMC INC Site Address: NOT ASSIGNED BRICKYARD BLDG 5 Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 2/9/2026 11:10:24 AM DWV for south end approved. Note: 2 areas were moved significantly, please revise to match red lines.

 02/17/2026B:UNGRD PLUMBMARTIN MAGERSPARTIALeTRAKiT Inspection Request2/13/2026 4:05:30 PM 2/13/2026 4:05 PM UMC INC underground storm area a Contact Name: UMC INC Site Address: NOT ASSIGNED BRICKYARD BLDG 5 Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 2/17/2026 12:25:52 PM P1 area A storm drain marked in orange.

 02/18/2026B:UNGRD PLUMBMARTIN MAGERSCANCELNATE 72040341622/17/2026 3:46:45 PM CALLED AFTER 4PM ON FRIDAY. LEFT MESSAGE FOR TUESDAY. 2/18/2026 12:34:50 PM Scheduled for wrong day

 02/19/2026B:UNGRD PLUMBMARTIN MAGERSPARTIALSouthwest area A storm2/18/2026 2:10:29 PM 2/18/2026 2:10 PM UMC INC Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 2/19/2026 11:49:03 AM Ground plumbing for storm drain West portion of Sector A approved. See picture of P101 outlined in orange.

 02/20/2026B:UNGRD PLUMBMARTIN MAGERSPARTIALeast area a sand oil piping2/19/2026 2:27:00 PM 2/19/2026 2:27 PM UMC INC Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 2/20/2026 2:07:05 PM Sand and oil drain lines south of 1.7. Marked in blue on P101. Note sand trap not yet installed.

 02/25/2026B:RGH MECHJOE CARBAUGHNOT APPROVEDCourtesy Inspection for Slap Penetration2/19/2026 6:59:08 AM 2/19/2026 6:59 AM STEELE BROS HEATING INC Contact Name: Pablo Hernandez Site Address: 444 FIFER ST Phone: 3039446370 e-Mail: pablo@steelebros.net 2/25/2026 11:21:33 AM RGH MECH - NOT APPROVED. NOTE: MEETING WAS WITH LEAD SUPERINTENDENT CLYDE GEORGE & HIS CREW. THE FOLLOWING WAS DISCUSSED - TALKS ABOUT MEP PENETRATIONS , RATED ASSEMBLIES, INSPECTION PROCESS & PHASE INSPECTIONS. QUESTIONS ABOUT SUBMITTALS WERE DISCUSSED & SETTING UP A PRE-CON MEETING WITH INSPECTION/DEVELOPMENT SERVICE SERVICES TEAM TO ANSWER ANY FURTHER QUESTIONS THAT THE BUILDER MAY HAVE.

 02/25/2026B:UNGRD PLUMBMARTIN MAGERSPARTIALsand oil west 1.7-1.102/25/2026 4:22:25 AM 2/25/2026 4:22 AM UMC INC Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 2/25/2026 3:04:18 PM Sand and oil drain up through 1.9 marked in blue P101

 02/27/2026B:ELECTRICAL SERVICESHAWN VALENZUELAPARTIALeTRAKiT Inspection Request1/7/2026 9:25:30 AM 1/7/2026 9:25 AM Clyde George UFER inspection Contact Name: Clyde George Site Address: NOT ASSIGNED BRICKYARD BLDG 5 Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 2/26/2026 2:39:55 PM 2/26/2026 2:39 PM Clyde George Underground conduit on south side P1 electric room. Contact Name: Clyde George Site Address: 444 FIFER ST Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 2/27/2026 9:13:41 AM Service conduits entering the building South east side of the building

 03/05/2026B:ELECTRICAL SERVICEVINCE RAPONEPARTIALeTRAKiT Inspection Request3/4/2026 11:01:30 AM 3/4/2026 11:01 AM Clyde George Electrical underground conduit on north side P1 electric room. Contact Name: Clyde George Site Address: 444 FIFER ST Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 3/5/2026 12:36:32 PM Under ground service for house panels good

 03/11/2026B:UNGRD PLUMBMARTIN MAGERSPARTIALeTRAKiT Inspection Request3/11/2026 4:56:36 AM 3/11/2026 4:56 AM UMC INC 1.7-1.9 west storm and sand oil piping Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 3/11/2026 12:16:41 PM Storm Water and Sand oil drains through 1.9 as marked on P101.

 03/12/2026B:UNGRD PLUMBMARTIN MAGERSPARTIALEast side Sand oil 1.9-1.163/12/2026 5:57:51 AM 3/12/2026 5:57 AM UMC INC Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 3/12/2026 2:11:39 PM Small sections of DWV and storm water up to 1.9. Marked on plans.

 03/13/2026B:ELECTRICAL UNDERGRSHAWN VALENZUELAPARTIALeTRAKiT Inspection Request3/12/2026 2:53:39 PM 3/12/2026 2:53 PM Clyde George P1 electrical underground partial. Contact Name: Clyde George Site Address: 444 FIFER ST Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 3/13/2026 10:05:14 AM Electrical underground partial approved Underground conduit feeding commercial spaces / house panel equipment 3/13/2026 1:56:31 PM Electrical underground partial approved

 03/16/2026B:UNGRD PLUMBMARTIN MAGERSPARTIALEast sand oil line to tank tie in3/13/2026 3:37:11 PM 3/13/2026 3:37 PM UMC INC Completes southeast sand oil piping to tank Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 3/16/2026 11:31:59 AM Sand and Oil drain through 1.6 as marked in red on P-102.

 03/16/2026B:ELECTRICAL SERVICEVINCE RAPONEPARTIALunderground3/13/2026 1:58:25 PM 3/13/2026 1:58 PM Clyde George Underground conduit from P1 electric room north. Contact Name: Clyde George Site Address: 444 FIFER ST Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 3/16/2026 1:33:09 PM Underground 16 - 3" pvc panel feeds 1 - 1-1/2" elevator feed

 03/17/2026PRE CON INSPECTIONBRETT LONGNECKERAPPROVED3/17/2026 9:24:52 AM Building pre-con conducted on March 17th, 2026 at 8:00 am in Rhyolite Conference Room.

 03/23/2026B:UNGRD PLUMBMARTIN MAGERSPARTIALeTRAKiT Inspection Request3/20/2026 5:50:17 PM 3/20/2026 5:50 PM UMC INC west sand oil 1.9- 1.19 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 3/23/2026 11:39:15 AM Sand and grease drain through 1.9

 03/24/2026B:UNGRD PLUMBMARTIN MAGERSPARTIAL1.9-1.19 west sanitary sewer3/24/2026 5:04:46 AM 3/24/2026 5:04 AM UMC INC Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 3/24/2026 3:05:35 PM Drain through 1.19 marked in green on P102.

 03/26/2026B:UNGRD PLUMBMARTIN MAGERSPARTIAL1.10 sand oil stack, 1.9 storm stack3/25/2026 12:42:26 PM 3/25/2026 12:42 PM UMC INC Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 3/26/2026 10:04:00 AM Small fill in for sand and grease and storm drain on P101 1 10, 1.9 approved ok to cover. Marked in red.

 03/27/2026B:UNGRD PLUMBMARTIN MAGERSCANCELeast sand oil 1.16-1.203/26/2026 2:20:58 PM 3/26/2026 2:20 PM UMC INC Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 3/27/2026 8:56:16 AM Please do not schedule both AM and PM on the same day.

 03/27/2026B:UNGRD PLUMBMARTIN MAGERSPARTIAL8" san sewer cconnection to sand oil3/27/2026 5:03:18 AM 3/27/2026 5:03 AM UMC INC this is seperate from the other inspection called in. If possible, need this in afternoon Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 3/27/2026 3:06:17 PM Sand and Oil ground drain through just before 1.20 and waste ground drain sand oil separator tie in labeled on P-102 in green waste, and red Sand oil.

 03/31/2026B:UNGRD PLUMBBRETT LONGNECKERPARTIAL8" SS from SOI to 1.203/30/2026 8:41:30 PM 3/30/2026 8:41 PM UMC INC 8" SS main with 4" and 6" risers for branches and cleanout Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 3/31/2026 1:15:09 PM SOI 8 inch underground ok to cover as highlighted in yellow on P-102.

 03/31/2026B:ELECTRICAL SERVICEVINCE RAPONEPARTIALeTRAKiT Inspection Request3/30/2026 3:05:49 PM 3/30/2026 3:05 PM Clyde George Electrical undergrounds at P1 SOG 4. Contact Name: Clyde George Site Address: 444 FIFER ST Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 3/31/2026 2:03:34 PM Electrical panel feed stub ups good

 04/06/2026B:UNGRD PLUMBBRETT LONGNECKERPARTIALSS 1P/1.21-1.244/3/2026 1:17:12 PM 4/3/2026 1:17 PM UMC INC 8" san main with stub ups for branches Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 4/6/2026 3:35:55 PM 8 inch waste at gridlines 1P and 1.21 through 1.24 ok.

 04/07/2026B:UNGRD PLUMBBRETT LONGNECKERPARTIAL6" san sew 1.22-1.274/7/2026 5:07:09 AM 4/7/2026 5:07 AM UMC INC west side of P1 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 4/7/2026 3:20:12 PM Underground plumbing ok as highlighted in blue on P-102 and P-103.

 04/10/2026B:RGH ELECTSHAWN VALENZUELAPARTIALIn slab electrical conduit/boxes.4/9/2026 1:39:46 PM 4/9/2026 1:39 PM Clyde George Level 1 elevated deck, pour 1. Contact Name: Clyde George Site Address: 444 FIFER ST Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 4/10/2026 2:20:45 PM Rough electrical partial approved Elevated deck inspection for only part of 1st floor deck south end of deck. Verify supporting of pvc conduits. For lighting, power, carbon monoxide, and fire alarm. Please call rough electrical inspection when the rest of elevated decking for level 1 is ready

 04/10/2026B:UNGRD PLUMBCOLBY RIGGINSPARTIALsanitary branches 1.20, 1.22 sand oil 1.4/9/2026 6:45:51 AM 4/9/2026 6:45 AM UMC INC sanitary branches 1.20, 1.22 sand oil 1.20- 1.26 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 3037766659 e-Mail: RENEE.PENICK@UMC.US 4/10/2026 4:54:46 AM 4/10/2026 4:54 AM UMC INC sand oil 1.20- 1.25 Sanitary branches 1.20, 1.22 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 4/10/2026 2:59:22 PM sanitary branches 1.20, 1.22 ok sand oil 1.20- 1.26 ok 4/10/2026 3:03:42 PM sanitary branches 1.20, 1.22 ok sand oil 1.20- 1.26 ok

 04/13/2026B:ELECTRICAL SERVICEVINCE RAPONEPARTIALP1 SOG 44/10/2026 12:21:48 PM 4/10/2026 12:21 PM Clyde George Underground conduit. Contact Name: Clyde George Site Address: 444 FIFER ST Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 4/13/2026 2:30:53 PM Extending P1 pvc feed 2- 4"

 04/14/2026B:UNGRD PLUMBBRETT LONGNECKERPARTIALStorm North Basement Parking4/13/2026 3:06:34 PM 4/13/2026 3:06 PM UMC INC 10" storm from H wall to 15'' past 1.25 6" storm at midwall 1.25 to 15'' past 1.25 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 4/14/2026 10:59:19 AM Storm drain underground ok for basement parking north end as highlighted in yellow on P102 and P103.

 04/23/2026B:UNGRD PLUMBMARTIN MAGERSPARTIALL1 waste-1.2-1.64/22/2026 8:10:21 PM 4/22/2026 8:10 PM UMC INC Main and future stub ups for TI spaces-tie in on P1 under ramp Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 4/23/2026 11:15:09 AM DWV through 1.6 4 and 6 in pipe ok as marked in green on page P-101.

 04/23/2026B:RGH ELECTVINCE RAPONEPARTIALL1 deck 24/22/2026 11:37:32 AM 4/22/2026 11:37 AM Clyde George In-slab conduit/boxes at level 1 elevated deck pour 2. Contact Name: Clyde George Site Address: 444 FIFER ST Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 4/23/2026 1:45:48 PM Level 1 decking pour 2 electrical rough good Garage lights / FA

 04/27/2026B:UNGRD PLUMBMARTIN MAGERSPARTIAL8" san sewer4/24/2026 3:31:42 PM 4/24/2026 3:31 PM UMC INC 8" san sewer east side from 1.25 to out of building Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 3037766659 e-Mail: RENEE.PENICK@UMC.US 4/27/2026 1:55:45 PM 8" sanitary sewer up to 1.27 on P103 DWV through wall and up to main level at 1.65 on P 101.

 04/28/2026B:UNGRD PLUMBMARTIN MAGERSPARTIALL1 grease line4/27/2026 3:36:42 PM 4/27/2026 3:36 PM UMC INC level 1 - 4" grease line- tie in P1 under ramp to north of 1.7 column-deep main only with stub ups for clean outs and branches Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 3037766659 e-Mail: RENEE.PENICK@UMC.US 4/28/2026 2:39:03 PM Grease Waste through 1.7 shown in pink on P 101

 04/29/2026B:UNGRD PLUMBMARTIN MAGERSCANCEL4" sand oil piping4/29/2026 5:08:11 AM 4/29/2026 5:08 AM UMC INC sand oil main and branches 1.26 & 1.27 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 4/29/2026 2:53:43 PM Canceled per call from Nate.

 04/30/2026B:UNGRD PLUMBMARTIN MAGERSCANCELsand oil 1.26, 1.274/30/2026 4:24:30 AM 4/30/2026 4:24 AM UMC INC sand oil between 1.26 & 1.27, stack and area drain stub up near stair core Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 4/30/2026 11:48:13 AM Canceled per text from Nate.

 05/01/2026B:UNGRD PLUMBMARTIN MAGERSPARTIAL5/1/2026 2:36:51 PM Grease waste 4" pipe from 1. 7 to 1.14. With 3 clean outs.

 05/04/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALSand oil stacks5/4/2026 5:06:40 AM 5/4/2026 5:06 AM UMC INC sand oil running between 1.26, 1.27 stopping just west of 1L, running north with branch for area drain and stack at 1P/1.27- Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 5/4/2026 10:28:36 AM Sand oil marked on P103 in pink approved.

 05/05/2026B:ROUGH ELECTRICALVINCE RAPONECANCELL1 Deck 35/4/2026 11:19:24 AM 5/4/2026 11:19 AM Clyde George In-deck electrical Contact Name: Clyde George Site Address: 444 FIFER ST Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 5/5/2026 11:14:02 AM Cancel per Clyde

 05/05/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALnorth sanitary sewer connection5/5/2026 5:41:06 AM 5/5/2026 5:41 AM UMC INC north sanitary connection to civil outside building Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 3037766659 e-Mail: RENEE.PENICK@UMC.US 5/5/2026 12:16:08 PM Stub through and connection of 8" waste line. Anything outside of foundation will require a third party inspection as well.

 05/08/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALL1 deck 35/7/2026 12:15:51 PM 5/7/2026 12:15 PM Clyde George In slab electrical Contact Name: Clyde George Site Address: 444 FIFER ST Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 5/8/2026 11:23:38 AM Level 1 decking electrical rough good Garage lights and FA

 05/11/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALstorm, sanitary P1 and L15/11/2026 6:09:04 AM 5/11/2026 6:09 AM UMC INC Storm from 1.26 to 10", Sanitary from outside building to approx 1.29 with stub ups, 6" storm L1 at 1.7 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 3037766659 e-Mail: RENEE.PENICK@UMC.US 5/11/2026 12:10:48 PM Storm water as marked in yellow on P103 at grid line 1.27 Sewer line marked in purple on P 103 on grid line 1.30 Storm Water line through wall and stubbed up. Marked on purple on P 101 grid line 1.7

 05/13/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIAL12" storm with cleanouts and branches5/8/2026 2:47:01 PM 5/8/2026 2:47 PM UMC INC 1.26 piped east along 1.27 columns- to 10" running north Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 5/13/2026 4:34:30 AM 5/13/2026 4:34 AM UMC INC 12" storm from stair core to outside building-2 cleanouts, 1 10" branch Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 5/13/2026 2:44:20 PM Storm water 12" stub out on north side.

 05/14/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALsanitary near midwall,west along 1.285/14/2026 6:10:01 AM 5/14/2026 6:10 AM UMC INC sanitary from 1.26 north along midwall, east along 1.28 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 5/14/2026 2:24:59 PM Sami ray wast 1.27 rgiugh 1.28 marked on plans in purple. see pictures. 5/14/2026 2:29:31 PM Sanitary waste 1.27 through 1.28 marked on plans in purple. see pictures.

 05/15/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIAL6" sanitary5/15/2026 6:16:49 AM 5/15/2026 6:16 AM UMC INC 6" sanitary from 1.30 north near stair core under conduit Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 5/15/2026 12:10:49 PM 6" Sanitay from 1.31 to1.27. Marked in green on P 103.

 05/19/2026B:RE ROUGH ELECTRICALVINCE RAPONEPARTIALP1 SOG 5 electrical conduit underground.5/18/2026 2:47:50 PM 5/18/2026 2:47 PM Clyde George P1 SOG 5 underground. Contact Name: Clyde George Site Address: 444 FIFER ST Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 5/19/2026 12:57:00 PM Under slab for mdp 29 - 3" pvc pipes 2 - 2" pvc pipes

 05/20/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALL1 deck 45/19/2026 12:55:33 PM 5/19/2026 12:55 PM Clyde George In slab roughs. Contact Name: Clyde George Site Address: 444 FIFER ST Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 5/20/2026 1:53:51 PM L1 decking pour 4 approved Lights and FA

 05/22/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALLevel 1 leasing bathrooms5/22/2026 4:53:01 AM 5/22/2026 4:53 AM UMC INC level 1 near 1.9, 1F area- amenity bathrooms with mop sink and 2" branches for drinking founntian and DWB capped for future Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 3037766659 e-Mail: RENEE.PENICK@UMC.US 5/22/2026 2:54:03 PM DWV under ground for Bath area and mop sink in the amenities area approved as highlighted in green. Near 1.9, F

 05/27/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIAL10" storm, 8" sanitary, 6" sanitary5/27/2026 4:56:07 AM 5/27/2026 4:56 AM UMC INC 10" storm near north elevator, 8" sanitary near elevator, 6" sanitary at stair core south to 1.26 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 5/27/2026 12:44:27 PM Sanitary 1.26 to 1.28 east side marked in green, Storm 1.28 near elevator marked in yellow Sewer in the same area marked in purple on P -103.

 05/29/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIAL6" san, 8" storm, 6" sanitary5/29/2026 4:53:59 AM 5/29/2026 4:53 AM UMC INC 6" sanitary branch at northwest corner at midwall, 8" storm branch to midwall 1.28, 6" sanitary branch at 1.30 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 3037766659 e-Mail: RENEE.PENICK@UMC.US 5/29/2026 1:10:33 PM 6%34 sanitary branch at northwest corner at midwall, marked in purple 8%34 storm branch to midwall 1.28, 6%34 marked in yellow. sanitary branch at 1.30 marked in purple.see page P-103

 06/01/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALDogwash and bike storage6/1/2026 4:34:19 AM 6/1/2026 4:34 AM UMC INC 4" floor drain & 3" floor sink in dog wash, 4" floor drain in bike storage Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 6/1/2026 12:44:55 PM 4%34 floor drain & 3%34 floor sink in dog wash, 4%34 floor drain in bike storage, approved for under ground plumbing. See P-103 marked in yellow.

 06/02/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALSand oil 1.27 north6/2/2026 6:03:41 AM 6/2/2026 6:03 AM UMC INC 4" sand oil from 1.27 north, picking up area drain just north of 1.27 @1N grid, north to soi in trash room Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 6/2/2026 9:45:14 AM 4%34 sand oil from 1.27 north, picking up area drain just north of 1.27 @1N grid, north to soi in trash room, approved.

 06/03/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALsand oil stacks and final 6 area drains6/3/2026 6:01:08 AM 6/3/2026 6:01 AM UMC INC North ramp area drains, and all other drains and stacks in p103. Sanitary- janitor colset mop sink, vent and 4" stack Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 6/3/2026 11:54:31 AM North ramp area drains, and all other drains and stacks in p103.

 06/05/2026B:GROUND PLUMBINGCOLBY RIGGINSPARTIALL1- 4" grease6/4/2026 4:57:21 PM 6/4/2026 4:57 PM UMC INC 4” grease waste with future stub ups and cleanouts 1.13-1.22 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 6/5/2026 10:26:26 AM L1- 4" grease, two cleanouts two future stub ups, p102 highlighted in pink.

 06/09/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALL1 fitness washer and sanitary6/9/2026 4:19:09 AM 6/9/2026 4:19 AM UMC INC 2" washer drain for fitness center near leasing office Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 6/9/2026 6:01:02 AM 6/9/2026 6:01 AM UMC INC 2” washer drain 1.13/1F 4”&6” sanitary @ 1.19-1.21 /1H level 1 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 6/9/2026 2:48:08 PM 4 and 6 in sanitary drains and washer box 2" drain as marked in green on P-102, approved.

 06/11/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALlevel 2 deck pour 16/10/2026 7:48:36 AM 6/10/2026 7:48 AM Jaden Chismar Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 6/11/2026 12:22:34 PM Deck pour 1 level 2 approved 1st floor - Lighting / FA 2nd floor - kit island pipes

 06/12/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIAL6" storm6/11/2026 3:34:52 PM 6/11/2026 3:34 PM UMC INC Level 1 -6” storm 1.21 north to 1.25 through wall to P1 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 6/12/2026 8:40:17 AM Level 1 -6" storm 1.21 north to 1.25 through wall to P1

 06/18/2026B:ELECTRICAL TEMPORARY CONSTRUCTION METERVINCE RAPONEAPPROVEDTemp power meter release inspection6/17/2026 10:07:15 AM 6/17/2026 10:07 AM Luke Hinder Contact Name: Luke Hinder Site Address: 444 FIFER ST Phone: 3039610137 e-Mail: lukeh@1stelectric.net 6/18/2026 12:11:25 PM Temp construction meter approved Okay to release meter

 06/24/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALLevel 2 Deck Pour 26/23/2026 12:36:07 PM 6/23/2026 12:36 PM Luke Hinder Contact Name: Luke Hinder Site Address: 444 FIFER ST Phone: 3039610137 e-Mail: lukeh@1stelectric.net 6/24/2026 2:39:39 PM Level 2 pour 2 electrical rough approved Garage lighting / FA

 06/24/2026B:ROUGH PLUMBINGMARTIN MAGERSPARTIALArea drains6/24/2026 6:15:42 AM 6/24/2026 6:15 AM UMC INC Level 1 area drains- piping in P1 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 6/24/2026 2:43:33 PM Sand Oil drains from level 1. Marked in purple on P101 and P102.

 06/26/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALLevel 1 sanitary-6/26/2026 4:19:03 AM 6/26/2026 4:19 AM UMC INC Sanitary sewer 1.28 - 1.30 3-4” stacks, 1- 6” stack with 6” penetrating midwall into P1 garage Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 6/29/2026 8:27:36 AM 3-4" stacks, 1- 6" stack with 6" penetrating midwall into P1 garage approved. All Groung plumbing is complete as marked on plans, please revise plans to as build and recall ground plumbing.

 07/01/2026B:RE ROUGH ELECTRICALVINCE RAPONEPARTIALLevel 2 Deck pour 3, pool deck rough in6/30/2026 1:25:29 PM 6/30/2026 1:25 PM Luke Hinder Contact Name: Luke Hinder Site Address: 444 FIFER ST Phone: 3039610137 e-Mail: lukeh@1stelectric.net 7/1/2026 1:41:16 PM Level 2 pour 3 approved Niche lights Planter j boxes Bbq grills

 07/08/2026B:ROUGH ELECTRICALSHAWN VALENZUELAPARTIALLevel 2 Deck Pour 47/7/2026 12:34:23 PM 7/7/2026 12:34 PM Luke Hinder Contact Name: Luke Hinder Site Address: 444 FIFER ST Phone: 3039610137 e-Mail: lukeh@1stelectric.net 7/8/2026 1:29:21 PM Rough electrical partial approved Level 2 deck pour 4 Parking lights/ fire alarm co and power in parking garage Kitchen island power on 2nd floor for units

 07/10/2026B:ROUGH ELECTRICALSHAWN VALENZUELAPARTIALLevel 1 Pour 5 Deck Inspection7/9/2026 7:02:12 AM 7/9/2026 7:02 AM Joel Van Valkenburgh Contact Name: Joel Van Valkenburgh Site Address: 444 FIFER ST Phone: 3039611229 e-Mail: joelv@1stelectric.net 7/10/2026 8:20:59 AM Rough electrical inspection partial approved Notes Level 1 pour 5 Lights, power, CO, car charger conduit Noted on prints what area was looked at and noted what area was look at on 7/8/26

 07/15/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALeTRAKiT Inspection Request7/14/2026 9:05:54 AM 7/14/2026 9:05 AM Joel Van Valkenburgh 2nd Floor Pour 5 Deck Rough Contact Name: Joel Van Valkenburgh Site Address: 444 FIFER ST Phone: 3039611229 e-Mail: joelv@1stelectric.net 7/15/2026 12:54:31 PM 2nd level pour 5 approved Clubhouse 2 - floor boxes / panel C Planter stubs

 07/20/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALeTRAKiT Inspection Request7/17/2026 9:01:11 AM 7/17/2026 9:01 AM Joel Van Valkenburgh Level 1 Pour 6 Rough Deck Inspection Contact Name: Joel Van Valkenburgh Site Address: 444 FIFER ST Phone: 3039611229 e-Mail: joelv@1stelectric.net 7/20/2026 11:32:38 AM Level 1 pour 6 approved Dog wash / bike resident storage

 07/23/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALeTRAKiT Inspection Request7/22/2026 7:07:33 AM 7/22/2026 7:07 AM Joel Van Valkenburgh Level 2 Pour 6 Rough Electrical Contact Name: Joel Van Valkenburgh Site Address: 444 FIFER ST Phone: 3039611229 e-Mail: joelv@1stelectric.net 7/23/2026 2:11:28 PM Level 2 deck pour 6 approved

 07/24/2026B:GROUND PLUMBINGMARTIN MAGERSPARTIALAdded underground RFI-1157/24/2026 3:44:10 AM 7/24/2026 3:44 AM UMC INC 2 bathroom groups, mop sink, kitchen and extra lav, and 4" future- Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 7/24/2026 10:14:35 AM 2 bathroom groups, mop sink, kitchen and extra lav, and 4%34 future- Please submit revision for all of this plumbing.

 07/30/2026B:RE ROUGH ELECTRICALVINCE RAPONEPARTIALLevel 2 Pour 7 Deck work7/29/2026 1:03:45 PM 7/29/2026 1:03 PM Luke Hinder Contact Name: Luke Hinder Site Address: 444 FIFER ST Phone: 3039610137 e-Mail: lukeh@1stelectric.net 7/30/2026 2:17:49 PM Level 2 pour 7 okay

 08/10/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALdeck pour 7 level 28/7/2026 9:06:45 AM 8/7/2026 9:06 AM Joel Van Valkenburgh Level 2 Pour 8 Deck Rough Call Luke (303) 961-0137 Contact Name: Joel Van Valkenburgh Site Address: 444 FIFER ST Phone: 3039611229 e-Mail: joelv@1stelectric.net 8/10/2026 1:30:49 PM Level 2 deck pour 7 approved Garage lighting and FA Planters for court yard

 08/14/2026B:RE ROUGH ELECTRICALVINCE RAPONEPARTIALLevel 2 pour 9 Deck Rough in8/13/2026 2:39:21 PM 8/13/2026 2:39 PM Luke Hinder Contact Name: Luke Hinder Site Address: 444 FIFER ST Phone: 3039610137 e-Mail: lukeh@1stelectric.net 8/14/2026 11:33:52 AM Level 2 deck pour 9 2 - kitchen islands Garage light

 08/18/2026B:ROUGH PLUMBINGMARTIN MAGERSPARTIALCourtesy Inspection8/18/2026 6:07:03 AM 8/18/2026 6:07 AM UMC INC Questions about sleeving, and castle rock standards for boring studs and top plates Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 8/18/2026 12:40:38 PM Consult only. Answered questions 1. Penetrations in a post tension floor will require structural engineering. 2. Penetrations in wood framing top plates and studs are outlined in the plans on S-702. Situations outside of these would require structural engineering.

 08/21/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALLevel 2 Deck pour 10.8/20/2026 1:37:55 PM 8/20/2026 1:37 PM Luke Hinder Last Deck pour Contact Name: Luke Hinder Site Address: 444 FIFER ST Phone: 3039610137 e-Mail: lukeh@1stelectric.net 8/21/2026 1:47:52 PM Level 2 deck pour 10 app 3 - kit islands Row of garage lights Electrical sleeves for electrical room

 08/25/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALUnderground Secondaries8/24/2026 10:27:53 AM 8/24/2026 10:27 AM Luke Hinder MSB-N, CMC, and Fire Pump underground. Contact Name: Luke Hinder Site Address: 444 FIFER ST Phone: 3039610137 e-Mail: lukeh@1stelectric.net 8/25/2026 2:03:07 PM East side 1 - 3" pvc for fire pump stubbed in CMC transformer CMC to transformer - 7 - 3" pvc MSBS to transformer - 13 - 3" pvc MSB to transformer 13 - 3" pvc Please update and revise print with fire pump on the electrical one line

 08/27/2026B:ELECTRICAL UNDERGRVINCE RAPONEPARTIALUnderground MSB & MSB-N8/26/2026 2:40:52 PM 8/26/2026 2:40 PM Luke Hinder Secondaries Contact Name: Luke Hinder Site Address: 444 FIFER ST Phone: 3039610137 e-Mail: lukeh@1stelectric.net 8/27/2026 2:10:19 PM Underground secondary's MSB to transformer continued - 13 conduits MSB-N to transformer stubbed to building

 09/14/2026B:PREROCKJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request9/11/2026 2:25:53 PM 9/11/2026 2:25 PM CONFLUENCE BUILDERS LLC I would like to inspect the first layer of pre-rock on our LVL beams that sit in our floor/ceiling assembly in phase 1 area B Contact Name: CONFLUENCE BUILDERS LLC Site Address: 444 FIFER ST Phone: 7202129237 e-Mail: Jaden@confluenceco.com 9/14/2026 3:29:45 PM NOT APPROVED- 1) FIRST LAYER OF 5/8" TYPE X GYP ON WOOD BEAM - OK PER DETAIL PS-3/ 1 TYP. WOOD BEAM ? PRIMARY STRUCTURE PROTECTION. ROOMS NOTE: LOOKING FOR CLARIFICATION ON THE PROTECTIONS OF THE BEAMS BEARING POINT AT BOTH ENDS. OK TWO ROCK SECOND LAYER.

 09/15/2026B:PREROCKJOE CARBAUGHPARTIALeTRAKiT Inspection Request9/14/2026 3:19:21 PM 9/14/2026 3:19 PM Jaden Chismar I want to inspect the 2nd layer of drywall on our LVL beams that sit in our floor ceiling assembly in area A and B Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 9/15/2026 10:20:53 AM PARTIAL- 1) SECOND LAYER OF 5/8" TYPE X GYP FOR LVL BEAM 1 HR. RATING - / ROOMS 286;& 258 - OK. NOTE : UPLOAD STAMPED DETAIL & STAMPED LETTER FROM ARCHITECTURAL & STRUCTURAL ENGINEER.

 09/25/2026B:ROUGH PLUMBINGMARTIN MAGERSPARTIALCourtesy Inspection9/24/2026 11:07:33 AM 9/24/2026 11:07 AM UMC INC Question about main water service in building Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 9/25/2026 3:40:03 PM Consult only on proposed variant to water tree design. Referred to Greg Swaney at the water dept.

 09/28/2026B:EXTERIOR AND INTERIOR SHEAR AND SHEATHINGJOE CARBAUGHPARTIALeTRAKiT Inspection Request9/25/2026 3:23:19 PM 9/25/2026 3:23 PM Jaden Chismar I would like to inspect exterior sheathing on level 2/3 on Phase 1 Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 9/28/2026 1:35:40 PM 1) ZIP SYSTEM 2ND FLOOR EXTERIOR SHEAR FOR PHASE ONE- SEE ATTACHMENT HIGHLIGHTED IN RED. In inspection notes under building 5 file.

 09/28/2026B:ROUGH FRAMEJOE CARBAUGHPARTIALeTRAKiT Inspection Request9/25/2026 3:22:21 PM 9/25/2026 3:22 PM Jaden Chismar I would like to inspect our CFMF on the exterior of the builidng on the south/east corner of the building,Grid lines 1.5-1L Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 9/28/2026 10:47:43 AM PARTIAL- EXTERIOR CFMF RGH FRAME P1 LEVEL S/E CORNER 1) MISSING CORRECT NUMBER OF RAMSET ATTACHMENT TO SLIP TOP TRACK 6" O.C. AS REQUIRED PER PLAN / S/E CORNER. 2) REST OF S/E CORNER P1 LEVEL 1 & 2 - OK.

 09/30/2026B:ROUGH ELECTRICALVINCE RAPONEPARTIALConsult9/28/2026 3:10:35 PM 9/28/2026 3:10 PM Clyde George Would like to discuss step lights at L2 patios. Contact Name: Clyde George Site Address: 444 FIFER ST Phone: 3034088187 e-Mail: cgeorge@confluenceco.com 9/30/2026 7:04:24 AM Wanting to remove patio lights L2 and above Myself or Jon will reach out to Clyde

 10/06/2026B:ROUGH FRAMEJOE CARBAUGHPARTIALeTRAKiT Inspection Request10/5/2026 2:39:18 PM 10/5/2026 2:39 PM Jaden Chismar I would like to inspect the CFMF on the South side of the building. Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/6/2026 10:08:28 AM PARTIAL- 1) FIRST FLOOR CFMF AT S/W CORNER- OK / SEE ATTACHMENT PICTURE IN INSPECTORS PHOTO FILE.

 10/07/2026B:ROUGH FRAMEJOE CARBAUGHPARTIALeTRAKiT Inspection Request10/6/2026 2:05:05 PM 10/6/2026 2:05 PM Jaden Chismar I would like to inspect the concealed hanger connection at our window headers on level 2 of area A. Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/7/2026 11:14:34 AM PARTIAL- 1) HUCQ612 CONCEALED HANGERS AT WINDOW HEADERS IN ROOMS 264, 266, 267, 269, 270, 277 AND 274 - OK.

 10/09/2026B:DRYWALL SHEAR WALLJOE CARBAUGHCANCELeTRAKiT Inspection Request10/8/2026 3:57:18 PM 10/8/2026 3:57 PM Jaden Chismar I would like to get a screw inspection for our exterior dens glass on level 1 East/South and West elevations Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/9/2026 3:13:51 PM CANCELED- 1) DUPLICATE INSPECTION .

 10/09/2026B:EXTERIOR AND INTERIOR SHEAR AND SHEATHINGJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request10/8/2026 3:55:54 PM 10/8/2026 3:55 PM Jaden Chismar I would like to inspect level 3 sheathing and level 2 corrections on Phase 1 Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/9/2026 3:13:53 PM NOT APPROVED- EXTERIOR SHEAR 3RD FLOOR 1) CORRECTIONS NEEDED- (FEILD) NAILING / TYPICAL NAILING AT WINDOWSILLS THROUGH OUT /CONFIRMED BUT JOINT TOLERANCES WITH ZIP SYSTEM. NOTE: RECALL INSPECTION WHEN CORRECTIONS HAVE BEEN MADE.

 10/13/2026B:EXTERIOR AND INTERIOR SHEAR AND SHEATHINGMARTIN MAGERSPARTIALeTRAKiT Inspection Request10/12/2026 3:48:48 PM 10/12/2026 3:48 PM Jaden Chismar I would like to inspect exterior gyp on level 1 on the south/east/west Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/13/2026 12:05:52 PM All gypsum sheathing south of 1.5 complete and approved. Highlighted in red on A131.

 10/16/2026B:EXTERIOR AND INTERIOR SHEAR AND SHEATHINGJOE CARBAUGHCANCELeTRAKiT Inspection Request10/15/2026 1:51:26 PM 10/15/2026 1:51 PM Jaden Chismar I would like to inspect Level 2 sheathing patches, Level 3 Sheathing corrections and Level 4 Sheathing of phase 1 Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/16/2026 8:55:45 AM CANCELED- NOTE: CONTRACTOR TRIED COUNSELING INSPECTION THE EVEN BEFORE INSPECTION.

 10/16/2026B:RE ROUGH FRAMEJOE CARBAUGHPARTIALeTRAKiT Inspection Request10/15/2026 1:50:10 PM 10/15/2026 1:50 PM Jaden Chismar I would like to inspect CFMF on the West side of the building. from grid line 1.5-1.17 Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/16/2026 8:55:47 AM PARTIAL- 1) CONCEALED HANGERS HU612 IN 371,376, 369,374 & 361 - OK.

 10/21/2026B:ROUGH FRAMEJOE CARBAUGHPARTIALeTRAKiT Inspection Request10/20/2026 1:20:21 PM 10/20/2026 1:20 PM Jaden Chismar CFMF on the west side of the building Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/21/2026 12:36:14 PM PARTIAL- 1) CFMF ON WEST SIDE OF PHASE ONE FIRST FLOOR- OK.

 10/22/2026B:EXTERIOR AND INTERIOR SHEAR AND SHEATHINGJOE CARBAUGHPARTIALeTRAKiT Inspection Request10/21/2026 3:20:54 PM 10/21/2026 3:20 PM Jaden Chismar I would like to inspect level 3 area A zip sheathing Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/22/2026 1:55:10 PM PARTIAL- 1) 3rd FLOOR FIRST PHASE EXTERIOR SHEAR CORRECTIONS ONLY- OK.

 10/22/2026B:ROUGH MECHANICALBRETT LONGNECKERNOT APPROVEDUnit Rough Consult10/21/2026 3:21:54 PM 10/21/2026 3:21 PM Jaden Chismar I would like to call a courtesy inspection for unit mechanical Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/22/2026 2:28:38 PM Rough Mech consult for unit ceiling damper fire assemblies and install only. Dryer duct length and elbows to be labeled at rough mech inspections.

 10/26/2026B:RE ROUGH FRAMEJOE CARBAUGHPARTIALeTRAKiT Inspection Request10/23/2026 3:26:27 PM 10/23/2026 3:26 PM Jaden Chismar I would like to inspect level 4 area A concealed hangers at headers Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/26/2026 11:16:30 AM PARTIAL- 1) MODIFIED FRAMING FOR CONCEALED HANGER AND HEADER HEIGHT OK PER RFI IN UNIT 480.

 10/28/2026B:ROUGH FRAMEJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request10/27/2026 3:15:10 PM 10/27/2026 3:15 PM Jaden Chismar I would like to inspect our temp plateform in the elevator shaft Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/29/2026 6:56:00 AM NOT APPROVED- TEMP PLATFORM FOR STAIR 2- 1) GUARDS NEED TO MEETING CODE FOR TEMP FALL PROTECTION FOR TEMPORARY SHAFT PLATE FORM . CURRENT GUARD IN (FRONT) OF ELEVATOR SHAFT - OK. 2) RE- SCHEDULE ONE ITEM HAS BEEN CORRECTED.

 10/28/2026B:EXTERIOR AND INTERIOR SHEAR AND SHEATHINGJOE CARBAUGHPARTIALeTRAKiT Inspection Request10/27/2026 3:15:50 PM 10/27/2026 3:15 PM Jaden Chismar I would like to inspect the CFMF sheathing on the west side of the building Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/29/2026 6:56:03 AM PARTIAL- 1) EXTERIOR SHEAR FOR FIRST FLOOR WEST / GRID LINES 1.5 to 1.7, & 1.8 to 1.14- OK.

 10/28/2026B:PREROCKJOE CARBAUGHPARTIALeTRAKiT Inspection Request10/27/2026 3:14:17 PM 10/27/2026 3:14 PM Jaden Chismar I would like to inspect the pre-rock on level 5 for roof truss installation Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/29/2026 6:56:05 AM PARTIAL- 1) HEAD OF WALL FRAMING VERIFIED IN AREA 1C LEVEL FIVE - OK. 2) 5/8" TYPE X (AMERICAN) GYP AT HEAD OF WALL FRAMING VERIFIED PER U305 - OK, LEVEL 5 AREA 1C.

 10/29/2026B:DRYWALLJOE CARBAUGHPARTIALeTRAKiT Inspection Request10/28/2026 3:46:45 PM 10/28/2026 3:46 PM Jaden Chismar Level 5 1C 2nd layer pre-rock for roof truss installation Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/29/2026 2:32:49 PM PARTIAL- 1) EXP 5/8 TYPE X AT (HEAD OF WALL) IN AREA'S HIGHLIGHTED IN RED SEE PICTURE IN INSPECTION PHOTOS, LEVEL FIVE/ PAGE ? 105 OF NATIONAL STATES GYP & AMERICAN GYP CAN BE USED PER U305- OK. NOTE: SECOND LAYER OF GYP IS FOR SOUND (ONLY) NOT PART OF U305 LISTENING.

 10/30/2026B:EXTERIOR AND INTERIOR SHEAR AND SHEATHINGJOE CARBAUGHPARTIALeTRAKiT Inspection Request10/29/2026 3:17:46 PM 10/29/2026 3:17 PM Jaden Chismar I would like to inspect Level 4 Area A exterior sheathing Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/30/2026 11:29:35 AM PARTIAL- 1) EXTERIOR ZIP SHEAR FOR LEVEL FOUR HIGHLIGHTED RED ON PLANS, SEE INSPECTOR PHOTO FILE FOR DETAIL.

 10/30/2026B:ROUGH FRAMEJOE CARBAUGHPARTIALeTRAKiT Inspection Request10/29/2026 3:15:50 PM 10/29/2026 3:15 PM Jaden Chismar I would like to inspect Head of wall at level 5 for our pre-rock activaties Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 10/30/2026 11:29:37 AM PARTIAL- 1) HEAD OF WALL FRAMING AT 4TH FLOOR (HIGHLIGHTED) AREAS ONLY IN AREA 1 A & 1 B. - OK.

 11/03/2026B:ROUGH FRAMEJOE CARBAUGHPARTIALeTRAKiT Inspection Request11/2/2026 5:05:50 PM 11/2/2026 5:05 PM Jaden Chismar I would like to inspect our temp elevator platform in stair 2 Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/3/2026 1:48:05 PM PARTIAL- 1) SHAFT TWO LEVEL FIVE TEMPORARY PLATFORM- OK PER OSHA REQUIREMENTS.

 11/03/2026B:EXTERIOR AND INTERIOR SHEAR AND SHEATHINGJOE CARBAUGHPARTIALeTRAKiT Inspection Request11/2/2026 5:04:18 PM 11/2/2026 5:04 PM Jaden Chismar I would like to inspect level 5 sheathing Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/3/2026 1:48:08 PM PARTIAL- 1) FIFTH FLOOR EXTERIOR SHEAR AREA MARKED IN RED ONLY DIGITALLY ON PLANS - OK. SEE PICTURE IN INSPECTOR PHOTOS UNDER BUILDING 5.

 11/05/2026B:DRYWALLJOE CARBAUGHNOT APPROVEDeTRAKiT Inspection Request11/4/2026 2:58:57 PM 11/4/2026 2:58 PM Jaden Chismar I would like to call a courtesy inspection for our shafts in Phase 1 area A Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/5/2026 11:58:49 AM NOT APPROVED. 1) THIS WAS A COURTESY INSPECTION TO DISCUSS INSPECTION PROCESS FOR DRYWALL INSPECTION AT SHAFT ASSEMBLIES & CONSTRUCTIBILITY FOR TOP OF SHAFT/ DOG FRAMING FOR THE SHAFTS. NOTE: ANY CHANGES TO RATED ASSEMBLY WILL NEED TO BE DESIGNED , STAMPED & SUBMITTED TO THE TOWN.

 11/06/2026B:PREROCKMARTIN MAGERSPARTIALeTRAKiT Inspection Request11/5/2026 3:37:11 PM 11/5/2026 3:37 PM Jaden Chismar I would like to inspect the framing behind the pre-rock areas Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/6/2026 2:26:03 PM This is a framing inspection for the areas to be pre rocked. Area A on 5th floor approved.

 11/09/2026B:PREROCKJOE CARBAUGHPARTIALeTRAKiT Inspection Request11/6/2026 12:22:24 PM 11/6/2026 12:22 PM Jaden Chismar I would like to inspect the Pre-rock areas in level 2 and level 3 Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/9/2026 10:36:12 AM PARTIAL- 1) PRE ROCK INSPECTIONS FOR CONCEALED SPACES IN AREA (A) AS HIGHLIGHTED ON DIGITAL PLANS & IN INSPECTION PHOTOS FILE. - OK.

 11/10/2026B:ROUGH FRAMEJOE CARBAUGHPARTIALeTRAKiT Inspection Request11/9/2026 10:44:05 AM 11/9/2026 10:44 AM Jaden Chismar I would like to inspect the roof sheathing and the roof couch framing Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/10/2026 9:30:02 AM PARTIAL- 1) ALL OF PHASE 1 ROOF DECKING, NAILING, CLIPS - OK. 2) RGH FRAME ON ROOF COUCHES ( WALLS ONLY) - OK. FLOOR FRAMING FOR ROOF COUCHES TO BE INSPECTED AT FUTURE INSPECTION. 3) FRT SHEATHING MEETS CODE REQUIREMENT OF MINIMUM 4' FROM RATED ASSEMBLY- OK. NOTE: REMINDER OF NO ROOF PENETRATIONS WITH IN A MINIMUM OF 4' OF FIREWALL. FLOOR FRAMING FOR ROOF COUCHES TO BE INSPECTED AT FUTURE INSPECTION.

B:BUILDING SEPERATION WALLBRETT LONGNECKEReTRAKiT Inspection Request10/27/2026 3:13:10 PM 10/27/2026 3:13 PM Jaden Chismar I would like to inspect the CFMF Sheathing screw on the west side of the building Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/12/2026 3:18:57 PM 11/12/2026 3:18 PM Jaden Chismar I would like to inspect the level 2-5 corridors for joist framing Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com

 11/13/2026B:ROUGH FRAMEJOE CARBAUGHPARTIALeTRAKiT Inspection Request11/12/2026 3:20:13 PM 11/12/2026 3:20 PM Jaden Chismar I would like to call in the corridor joist framing for levels 2-5 Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/13/2026 11:20:27 AM PARTIAL- 1) RGH FRAME CORRIDOR, CEILING FRAMING (ONLY) LEVELS 3 & 2 - OK. NOTE: NEED CLARIFICATION ON CONCEALED SPACE BETWEEN STAIR 2 CMU UNIT 2.1.1 & UNIT 0.1 ON 3rd FLOOR.

 11/13/2026B:PREROCKJOE CARBAUGHPARTIALeTRAKiT Inspection Request11/12/2026 3:20:58 PM 11/12/2026 3:20 PM Jaden Chismar I would like to inspect levels 2-5 concealed spaces for pre-rock Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/13/2026 11:20:29 AM PARTIAL- 1) RGH FRAME / PRE-ROCK IN CONCEALED SPACES FOR WALL FRAMING ON LEVEL 5 MISSING H2.5T AT HEAD OF WALL AT R255 ROOF TRUSS IN CONCEALED SPACE. REST OF LEVEL 5 AREA B - OK. 2) RGH FRAME / PRE-ROCK IN CONCEALED SPACES FOR WALL FRAMING ON LEVELS 4,,3 & 2 AREA B - OK.

 11/13/2026B:ROUGH PLUMBINGMARTIN MAGERSPARTIALArea drain piping 1.27 and 1.2611/12/2026 10:01:43 AM 11/12/2026 10:01 AM UMC INC L1 area drains piped to stacks on P! Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 11/13/2026 4:25:07 PM P 103 1.26 and 1.27 floor drain said and oil x 5, one not on test

 11/17/2026B:ROUGH FRAMEJOE CARBAUGHPARTIALeTRAKiT Inspection Request11/16/2026 3:34:11 PM 11/16/2026 3:34 PM Jaden Chismar I would like to inspect my CFMF from gridline 1.17-1.32 Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/17/2026 11:08:51 AM PARTIAL- 1) CFMF ON 1ST FLOOR WEST FROM GRID LINE 117 THROUGH GRIDE 2.47 - OK. 2) SECOND FLOOR CONCEALED HEADER HANGERS - OK SOUTHWEST UNITS. NOTE: SPOKE WITH JADEN ASST SUPERINTENDENT ABOUT THE U357 FIRE SEPARATION WALL BETWEEN PHASE 1 & 2 ABOUT THE HORIZONTAL AIR GAPS BETWEEN SEEMS OF ASSEMBLY & AND LOOKING FOR CLARIFICATION FROM COLORADO DESIGN PROFESSIONAL IS AS BUILT IS OK OR H CHANNEL IS REQUIRED.

 11/18/2026B:EXTERIOR AND INTERIOR SHEAR AND SHEATHINGJOE CARBAUGHPARTIALeTRAKiT Inspection Request11/17/2026 4:36:59 PM 11/17/2026 4:36 PM Jaden Chismar I would like to inspect the zip sheathing on the exterior for levels 4/5 in areas B and C Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/18/2026 3:25:08 PM PARTIAL- 1) 5TH & 4th FLOOR EXTERIOR SHEAR ZIP SYSTEM FOR AREA'S B & C - OK.

 11/18/2026B:DRYWALLJOE CARBAUGHPARTIALeTRAKiT Inspection Request11/17/2026 4:36:10 PM 11/17/2026 4:36 PM Jaden Chismar I would like to inspect the screws for the pre-rock areas on level 3-5 Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/18/2026 3:25:10 PM PARTIAL- 1) DRYWALL FOR CONCEALED SPACES AND TUBS OK AS HIGHLIGHTED ON PLANS FOR LEVEL 5 AND 4 ARE A. SEE PICS AND INSPECTION PHOTO FILE.

 11/19/2026B:PRE_ROCKJOE CARBAUGHPARTIALeTRAKiT Inspection Request11/18/2026 5:27:27 PM 11/18/2026 5:27 PM Jaden Chismar I would like to inspect level 2/3 drywall screw in concealed spaces and tub/showers Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/19/2026 12:46:30 PM PARTIAL- 1) FRAME INSPECTION FOR CONCEALED SPACES & TUBS AS MARKED ON DITAL PLANS.

 11/19/2026B:ROUGH FRAMEJOE CARBAUGHPARTIALeTRAKiT Inspection Request11/18/2026 5:26:02 PM 11/18/2026 5:26 PM Jaden Chismar I would like to inspect concealed hangers on level 3 headers in are ma B/C Contact Name: Jaden Chismar Site Address: 444 FIFER ST Phone: 9706726538 e-Mail: Jaden@confluenceco.com 11/19/2026 12:46:32 PM PARTIAL- 1) CONCEALED HANGERS AT HEADERS OF WINDOW OPENINGS AS HIGHLIGHTED ON DITAL PLANS FOR ( PARTIAL) LEVEL OF 2 & 3 AREA B & C - OK.

B:ROUGH ELECTRICALVINCE RAPONEeTRAKiT Inspection Request11/20/2026 3:00:42 PM 11/20/2026 3:00 PM Joel Van Valkenburgh Phase 1 Section A Couch Inspection Contact Name: Joel Van Valkenburgh Site Address: 444 FIFER ST Phone: 3039611229 e-Mail: joelv@1stelectric.net

 11/20/2026B:ROUGH PLUMBINGMARTIN MAGERSPARTIALPartial main gas11/19/2026 3:15:36 PM 11/19/2026 3:15 PM UMC INC Gas piping from meter into building- pool deck, 3”, 4”, 1-1/2” with risers to 5th floor and temporary stub outs on risers for temp heat L2,L3,L4 Contact Name: UMC INC Site Address: 444 FIFER ST Phone: 7204034162 e-Mail: RENEE.PENICK@UMC.US 11/20/2026 3:10:01 PM Main trunk line from meter to 1.23 , 2 1 1/2 in and 1 3" brach lines gas lines vertical up through the floor of the 5th floor. Ok to release meter for temp heat on these lines.