| 03/06/2025 | T:INITIAL | BRIAN LASCHANZKY | APPROVED | | 3/6/2025 2:49:01 PM
This lot has many retaining walls planned and several are over 4ft in height. Retaining walls 4ft or over MUST be ENGINEERED and a Retaining Wall PERMIT obtained from the Town of Castle Rock. Retaining wall height INCLUDES the Height of the footing. For example, if the wall is 3ft high from grade with a 1ft footing pad, the height of the retaining wall would be 4FT NOT 3Ft. Reference the permit number for retaining wall(s) on Plot plan and on Final Grade certificate plan
3/6/2025 2:54:45 PM
Repair one section of Silt Fence (SF) that is sagging needs re-attached. The remainder of SF is. No tracking noted at this time. good. Inlet Protection for Area Inlet on-site and Type R inlet on street use of this alternative will be allowed at thios time for now Using alternative rock sock not wire When in need of maintenance, replace with Town of Castle Rock standard detail wire wrapped rock inlet protection for both the AREA INLET and type R inlet.
|
|
| 04/09/2025 | T:ROUTINE | BRIAN LASCHANZKY | TESC LIII | | 4/9/2025 1:12:14 PM
Sweep street curb and sidewalk clean out FODS and move them to the front at back of sidewalk as discussed today on-site. Good seeing you. IP changed out looks good. Good work
|
|
| 05/05/2025 | T:ROUTINE | BRIAN LASCHANZKY | TESC LIII | | 5/5/2025 9:49:10 AM
4-9-25 inspection notes: Sweep street curb and sidewalk clean out FODS and move them to the front at back of sidewalk as discussed today on-site. Good seeing you. IP changed out looks good. Good work
5/5/2025 12:44:04 PM
Sweep entrance. Wrap SF at corner to prevent sediment transport out this front west corner. Clean sediment from FODS. Replace where damaged.
|
|
| 06/04/2025 | T:ROUTINE | BRIAN LASCHANZKY | TESC LIII | MUDDY CONDITIONS consider temp shut down | 6/4/2025 11:16:43 AM
Repair SF sweep Keep trade vehicles off muddy lot postpone deliveries if possible until the site dries out. If cannot , any tracking MUST be swept/scraped and fully CONTROLLED NO TRACKING SHOULD BE PRESENT ESPECIALLY OVERNIGHT
CONSIDER temp shut down to let the site dry out. fighting muddy conditions typically are not worth the potential costly issues, rutting up the site, tracking getting vehicles stuck the clean up is typically costly and can outweigh the lost day or two of construction.
|
|
| 06/24/2025 | R:TEMP CONST METER | ADAM KINDLE | APPROVED | TYLER 719-310-8208 | 6/24/2025 1:48:11 PM
Approved please release meter
|
|
| 07/02/2025 | T:ROUTINE | BRIAN LASCHANZKY | TESC LIII | KEEP EYE ON SITE AREA INLET | 7/2/2025 10:13:13 AM
SWEEP KJEEP A CLOSE EYE ON THE AREA DRAINAGE INLET ON-SITE DO NOT ALLOW IT TO GET CLOGGED OR BE UNPROTECTED. ROCK SOCKS PRESENT GOOD. REPAIR SECTION OF SF.
|
|
| 08/04/2025 | T:ROUTINE | BRIAN LASCHANZKY | TESC LIII | Watch stockpile slope could breach | 8/4/2025 12:38:23 PM
Stockpile sloe could easily breach the SF at the corner. Install reinforce SF berm up the toe of the slope or backfiull the foundation. This area is suseptable to a brech in a good rainstorm take action to prevent a breachsweep entrance. the rest is being maintained well.
|
|
| 09/02/2025 | T:ROUTINE | JESSUP SCHIELD | TESC LIII | see notes | 9/2/2025 3:58:48 PM
• Repair minor silt fence damage on north side of lot.
|
|
| 09/23/2025 | R:GRND PLUMBING | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 9/22/2025 1:58:57 PM
9/22/2025 1:58 PM AFAB PLUMBING LLC
Contact Name: AFAB PLUMBING LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196835788
e-Mail: AFABPLUMBING@GMAIL.COM
9/23/2025 10:38:42 AM
Approved
|
|
| 09/30/2025 | R:ELECTRICAL UNDERGR | VINCE RAPONE | PARTIAL | RECEPTACLES IN CONCRETE PAD | 9/29/2025 3:43:11 PM
TYLER 7193108208
9/30/2025 12:56:13 PM
3 - Floor outlets game room / exercise room good
|
|
| 10/07/2025 | T:ROUTINE | JESSUP SCHIELD | TESC LIII | see notes | 10/7/2025 3:30:04 PM
Repair minor silt fence damage on north side of lot.
Sweep street at entrance to site.
|
|
| 11/06/2025 | T:ROUTINE | JESSUP SCHIELD | TESC LIII | see attached | |
|
| 12/02/2025 | T:ROUTINE | JESSUP SCHIELD | TESC LIII | see notes | 12/3/2025 11:32:07 AM
• Extend VTC into lot. VTC very short.
• Repair erosion near inlet.
• Refresh inlet protection to the west of the property.
|
|
| 12/10/2025 | R:ELECTRICAL UNDERGR | VINCE RAPONE | PARTIAL | | 12/9/2025 3:37:48 PM
ADDISON 3036601341 if cant find pipe
tyler safehouse elctric 7193108208
back porch SW side of building PVC for electrical
12/10/2025 2:26:42 PM
Fire pit sleeve SW corner of house good
|
|
| 12/11/2025 | R:GAS PIPE AIR TEST | MARTIN MAGERS | PARTIAL | eTRAKiT Inspection Request | 12/10/2025 2:38:53 PM
12/10/2025 2:38 PM KOALA WATER HEATERS
Partial inspection for underslab gas stub at main level patio fireplace: 55,000 btus
Contact Name: KOALA WATER HEATERS
Site Address: 1993 AVENIDA DEL SOL
Phone: 7199003213
e-Mail: TIM@KOALAWATERHEATERS.COM
12/11/2025 3:34:40 PM
Partial on gas line to fireplace on patio.
|
|
| 12/23/2025 | R:WALL BRACING | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 12/22/2025 1:56:51 PM
12/22/2025 1:56 PM CASCO CONSTRUCTION LLC
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7193801140
e-Mail: CHRISP@CASCOCC.COM
12/23/2025 11:00:50 AM
1. Missing all hold downs.
2. Missing all details for portal framing. Nailing, blocking, strapping, 2x2 washes in sill bolts x2 on each side.
3. Missing all nails in #6 area, no staples allowed.
4. Block all seams.
5. Miss 3 in seam staples in random places throughout on #3 areas, check all.
|
|
| 12/30/2025 | R:WALL BRACING | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 12/29/2025 12:58:55 PM
12/29/2025 12:58 PM CASCO CONSTRUCTION LLC
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7193801140
e-Mail: Chrisp@cascocc.com
12/30/2025 3:37:58 PM
Corrections made
|
|
| 01/06/2026 | T:ROUTINE | JASON INGENTHRON | TESC LIII | see notes | 1/6/2026 5:18:39 PM
This inspection found the following deficiencies: maintenance for Type-R inlet protection, installation of inlet protection on Type-C catch basin, Silt fence repairs.
There is a file with photos and additional information that was uploaded 1.6.25
|
|
| 01/07/2026 | R:WTHR RESIS BARRIER | JOE CARBAUGH | PARTIAL | eTRAKiT Inspection Request | 1/6/2026 1:46:09 PM
1/6/2026 1:46 PM CASCO CONSTRUCTION LLC
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: Chrisp@CASCOCC.COM
1/7/2026 11:06:03 AM
TYVEK AREAS OK.
CALL LATH INSPECTION FOR NON TYVEK AREAS OR SECOND WEATHER BARRIER INSPECTION WHEN READY FOR STUCCO OR BRICK.
|
|
| 01/20/2026 | T:ROUTINE | JASON INGENTHRON | TESC LIII | See Notes | 1/20/2026 4:02:05 PM
Site visit conducted today, 1-20-26: inlet protection requires additional corrections to be functional, area drain controls are satisfactory for a temporary configuration. No tracking was observed; however additional improvements will be needed as we move out of frozen temperatures.
Email with photos sent to contractor. email function not working from iPad app
|
|
| 02/10/2026 | T:ROUTINE | JASON INGENTHRON | CANCEL | | 2/10/2026 3:35:30 PM
Site will be inspected tomorrow. The date listed on this item is incorrect therefore, inspection will be canceled.
|
|
| 02/12/2026 | T:ROUTINE | JASON INGENTHRON | TESC LIII | See Notes | 2/12/2026 1:59:56 PM
The type-R inlet in the roadway requires corrective action to create functional sediment protection. No gaps between the bags and no voids underneath the bags which would let untreated stormwater enter the system. Remove old, non-functional rock bags from inlet and ensure new design conform to Castle Rock standards. See attached photos.
Please send photos of the repaired inlet protection via email
|
|
| 02/18/2026 | R:ROUGH PLUMBING | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 2/17/2026 3:23:55 PM
2/17/2026 3:23 PM AFAB PLUMBING LLC
Contact Name: AFAB PLUMBING LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196835788
e-Mail: AFABPLUMBING@GMAIL.COM
2/18/2026 12:34:44 PM
Water and DWV test ok
1. Vents not extended trough roof.. please remove caps, exstend vents trough roof and recall.
|
|
| 02/23/2026 | R:ROUGH PLUMBING | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 2/20/2026 7:55:02 AM
2/20/2026 7:55 AM AFAB PLUMBING LLC
Contact Name: AFAB PLUMBING LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196835788
e-Mail: AFABPLUMBING@GMAIL.COM
2/23/2026 12:17:50 PM
Approved
|
|
| 02/23/2026 | R:PORCH POST REAR | COLBY RIGGINS | NOT APPROVED | Special on interior vaulted ceilings | 2/18/2026 2:34:35 PM
2/18/2026 2:34 PM CASCO CONSTRUCTION LLC
Special on interior vaulted ceilings on main level
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: Chrisp@CASCOCC.COM
2/23/2026 12:17:53 PM
1. No plans onsite to verify details.
|
|
| 02/26/2026 | R:GAS PIPE AIR TEST | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 2/25/2026 9:07:00 PM
2/25/2026 9:07 PM KOALA WATER HEATERS
Contact Name: KOALA WATER HEATERS
Site Address: 1993 AVENIDA DEL SOL
Phone: 7199003213
e-Mail: TIM@KOALAWATERHEATERS.COM
2/26/2026 10:33:41 AM
No town approved gas iso on site. Please submit as built gas iso and recall when you can have printed approved plans on site.
|
|
| 02/27/2026 | R:ELECTRICAL UNDERGR | SHAWN VALENZUELA | PARTIAL | Tyler 7193108208 | 2/27/2026 12:13:34 PM
2 200 amp services coming off meter pedestal 2 200 amp disconnect will be installed at back of house (not installed at the time)
Meter pedestal needs to still be upgraded by core
2/27/2026 1:12:32 PM
2 200 amp services coming from meter pedestal
|
|
| 03/05/2026 | T:ROUTINE | JASON INGENTHRON | TESC LIII | see photos | 3/5/2026 5:34:31 PM
Site visit found several deficiencies with BMPs.
Silt fence must be trenched into the ground at several locations. Inlet protection requires modification and repair - close gaps between rock socks. VTC requires new rock and measures to be taken to prevent runoff from leaving the site via the driveway cut
|
|
| 03/06/2026 | T:ROUTINE | JASON INGENTHRON | TESC LIII | VOIDED (JAIN 3/6/2026) | 3/6/2026 11:08:07 AM
Site visit found several deficiencies requiring repair.:
Silt fence must be anchored into the ground. Several locations required trenching.
Inlet protection has gaps between the rock bags which allows sediment to enter the inlet. Remove sediment
from inlet, remove old rock bags from around Inlet, reposition rock bags to ensure no gaps exist, or replace with a continuous rock sock (or rock filled wire mesh).
VTC require requires maintenance at additional rock to stabilize entrance
Adjust site grade to prevent runoff from leaving the site down the driveway
3/6/2026 11:09:12 AM
Inspection voided by JAIN.
|
|
| 03/11/2026 | R:PORCH POST REAR | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 3/10/2026 1:09:08 PM
3/10/2026 1:09 PM CASCO CONSTRUCTION LLC
Special on truss hardware on vaults with osb lids
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: Chrisp@CASCOCC.COM
3/11/2026 9:26:19 AM
Posts and lid approved.
|
|
| 03/16/2026 | R:GAS PIPE AIR TEST | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 3/13/2026 2:14:06 PM
3/13/2026 2:14 PM KOALA WATER HEATERS
Printed Plans Located on top of Water Heater
Contact Name: KOALA WATER HEATERS
Site Address: 1993 AVENIDA DEL SOL
Phone: 7199003213
e-Mail: TIM@KOALAWATERHEATERS.COM
3/16/2026 2:46:33 PM
1. Pipe immediately leaving regulators 4 and 5 need to be upsized to 1" and 1 1/4" respectively. Please clearly which regulator was used and the capacity of 5hat regulator,
|
|
| 03/19/2026 | R:GAS PIPE AIR TEST | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 3/18/2026 10:44:38 PM
3/18/2026 10:44 PM KOALA WATER HEATERS
Contact Name: KOALA WATER HEATERS
Site Address: 1993 AVENIDA DEL SOL
Phone: 7199003213
e-Mail: TIM@KOALAWATERHEATERS.COM
3/19/2026 9:04:36 AM
Corrections made
|
|
| R:ROUGH MECHANICAL | MARTIN MAGERS | | eTRAKiT Inspection Request | 3/19/2026 9:00:42 AM
3/19/2026 9:00 AM CASCO CONSTRUCTION LLC
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
|
|
| 03/20/2026 | R:WTHR RESIS BARRIER | MARTIN MAGERS | APPROVED | Mid Roof Inspection | 3/19/2026 9:03:52 AM
3/19/2026 9:03 AM CASCO CONSTRUCTION LLC
Needing Mid Roof inspected before stocking roof tiles on the roof.
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
3/20/2026 9:33:03 AM
Mid roof approved for tile roof.
|
|
| 03/23/2026 | R:ROUGH MECHANICAL | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 3/19/2026 1:31:13 PM
3/19/2026 1:31 PM CASCO CONSTRUCTION LLC
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
3/23/2026 2:26:31 PM
Approved
|
|
| 03/31/2026 | R:LATH_STONE_BRICK | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 3/30/2026 3:27:51 PM
3/30/2026 3:27 PM CASCO CONSTRUCTION LLC
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
3/31/2026 12:34:57 PM
Approved
|
|
| 03/31/2026 | R:WTHR RESIS BARRIER | COLBY RIGGINS | APPROVED | | 3/31/2026 2:12:43 PM
Approved
|
|
| 04/03/2026 | R:ROUGH ELECTRICAL | VINCE RAPONE | NOT APPROVED | | 4/2/2026 4:03:41 PM
TYLER 7193108208
4/3/2026 10:55:01 AM
Garage - did not inspect - not ready
Bedroom ceiling fan no box
Pantry small appliance circuits - 4 devices per circuit
Stair switch incomplete
Basement coach lights need stubbed out in basement
Complete j box at basement low volt wall
Upstairs wire under framing in bathroom
Strap and secure all speaker wire and low volt wire
Pull 2 cold water and 2 user bonds. One for each service
|
|
| 04/03/2026 | T:ROUTINE | JASON INGENTHRON | TESC LIII | | 4/6/2026 7:48:25 AM
An email was sent to the Chris with Casco - it included photos of the deficiencies - the email function built into Track It is not working.
4/6/2026 8:22:54 AM
There are multiple violations on site. They are as follows: insufficient vehicle tracking control, dirt, track out offsite, silt fence damage damaged and in disrepair and nonfunctional
Send photos of corrected best management practices within two weeks of receiving this report. Also feel welcome to reach out to me with any questions.
|
|
| 04/13/2026 | R:ROUGH ELECTRICAL | VINCE RAPONE | PARTIAL | TYLER 7193108208 | 4/13/2026 10:36:30 AM
Rough electrical good - okay to insulate
Schedule rough electrical once service is complete
|
|
| 04/14/2026 | R:REQ PRE ROUGH DOC | BUILDING COUNTER | NOT APPROVED | eTRAKiT Inspection Request | 4/13/2026 1:48:50 PM
4/13/2026 1:48 PM CASCO CONSTRUCTION LLC
Pre-Rough Docs and Foundation Compliance Forms uploaded
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
4/14/2026 8:17:02 AM
WATER & SEWER; NO BURN
|
|
| 04/14/2026 | R:ROUGH FRAME | COLBY RIGGINS | NOT APPROVED | trusses | 4/13/2026 1:52:26 PM
4/13/2026 1:52 PM CASCO CONSTRUCTION LLC
Requesting Trusses only due to size of the home.
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
4/14/2026 3:11:50 PM
1. Missing sds screws on 3 ply girder at cg2 trusses into bearing blocks
2. All four ply girder trusses or more require sds screws on both sides or through bolts
3.ls 70 missing at upper level storage at 2x8 joist in the garage
4. At two ply girder left of garage entry door behind the master shower is missing a stud
5. Trusses f1-4 missing lateral bracing at web w3
6. Ls30 missing at h1 h2 trusses at rear slider
7. Please get an engineer judgement on detail s 3 (1) looks like the wrong detail the welding to the hanger in the great next to slider
8. Missing ledger at connection to h1 trusses
9. Ledger lock 2 at 16 onc at nj trusses at study closet
10. Uploaded engineer letter for G3 trusses modification for furnace on second floor
Note
Study and front and rear porch have been already looked at
|
|
| 04/15/2026 | R:ROUGH FRAME | COLBY RIGGINS | NOT APPROVED | Headers, Jacks & Kings for rough frame | 4/15/2026 6:20:57 AM
4/15/2026 6:20 AM CASCO CONSTRUCTION LLC
Headers, Jacks & Kings for rough frame
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
4/15/2026 2:39:45 PM
1. Three north facing first floor windows in the bedroom are missing king studs
2. Bathroom window next to the three north windows is missing a king stud on each side
3. South rear door next to fireplace is missing another king stud
4. Master bedroom door to exterior missing a king stud next to the fire place
5. Master bathroom missing a king stud on each side of the windows
6. Engineer letter for master bathroom side LVL's that run to the basement.
Steel ibeams not inspected
|
|
| 04/17/2026 | R:RE_ROUGH FRAME | COLBY RIGGINS | NOT APPROVED | eTRAKiT Inspection Request | 4/16/2026 12:51:41 PM
4/16/2026 12:51 PM CASCO CONSTRUCTION LLC
Re inspect Truss repairs and headers, trimmers and king stud corrections.
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
4/17/2026 2:33:41 PM
Headers, kings, trimmers:
1. Three north facing first floor windows in the bedroom are missing king studs
3. South rear door next to fireplace is missing another king stud, that is fixed but need to extend the cs to all 5 ply's
5. Master bathroom missing a king stud on each side of the windows, that is fixed but need cs to hit all ply's and hold down needs to be tightened down
6. Engineer letter for master bathroom side LVL's that run to the basement.
Steel ibeams not inspected
Trusses
2. All four ply girder trusses or more require sds screws on both sides or through bolts, missing at 4 lvl girder in the living room
7. Please get an engineer judgement on detail s 3 (1) looks like the wrong detail the welding to the hanger in the great next to slider
Fire blocking and point loads have not been inspected, also no ibeams and there welds have been inspected
Note
Study and front and rear porch have been already looked at
Engineer letter uploaded for G3 and G1A trusses
|
|
| 04/23/2026 | R:RE-ROUGH FRAME | COLBY RIGGINS | NOT APPROVED | eTRAKiT Inspection Request | 4/22/2026 12:43:27 PM
4/22/2026 12:43 PM CASCO CONSTRUCTION LLC
Re inspect truss, header and inspect fire/draft stop.
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
4/23/2026 2:22:43 PM
1. Unconditioned space in the master bedroom next to the fire place at the top plate by the entry door needs fire blocking
2. Upper storage room needs foam at white wire at the top plate
3. Stair stringers are not full bearing throughout, consult engineer on bearing
4. Welding for basement not complete
5. Verify 2 2x10 bearing at all stair landings that they bear into the elevator shaft if not add ls 70s
6. Remove temp blocking at bottom plates
7. Hangers need at landing in the basketball court for egress window
8. Front porch not inspected yet, please tear off part of the top to verify connections
Note
Call if fire resistive inspection and upload no burn
Get water and sewer 3rd party leaders uploaded to complete pre rough docs
Make sure fire passes fire sprinkler
|
|
| 05/04/2026 | R:REQ PRE ROUGH DOC | BUILDING COUNTER | NOT APPROVED | CB | 5/1/2026 2:35:04 PM
5/1/2026 2:35 PM CASCO CONSTRUCTION LLC
All Pre Rough Docs uploaded
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
|
|
| 05/04/2026 | R:ROUGH ELECTRICAL | VINCE RAPONE | APPROVED | electrical service | 5/4/2026 2:01:48 PM
Rough electrical approved
Electrical service approved okay to release meter
|
|
| 05/04/2026 | R:RE-ROUGH FRAME | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 5/1/2026 7:45:39 AM
5/1/2026 7:45 AM CASCO CONSTRUCTION LLC
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
5/4/2026 1:22:36 PM
3. Stair stringers are not full bearing throughout, consult engineer on bearing
7. Hangers need at landing in the basketball court for egress window
5/4/2026 4:39:20 PM
3. Stair stringers are not full bearing throughout, consult engineer on bearing
7. Hangers need at landing in the basketball court for egress window
|
|
| 05/06/2026 | R:REQ PRE ROUGH DOC | BUILDING COUNTER | APPROVED | CB | 5/5/2026 3:55:10 PM
5/5/2026 3:55 PM CASCO CONSTRUCTION LLC
All documents uploaded
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
|
|
| 05/07/2026 | T:ROUTINE | JASON INGENTHRON | TESC NONE | See attached | 5/7/2026 12:50:23 PM
Inspection was conducted 5/5/26 and inspection report has been sent via email and uploaded to the project file.
|
|
| 05/18/2026 | R:RE-ROUGH FRAME | MARTIN MAGERS | CANCEL | eTRAKiT Inspection Request | 5/17/2026 10:11:48 AM
5/17/2026 10:11 AM CASCO CONSTRUCTION LLC
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
5/18/2026 8:53:50 AM
Canceled per call with Chris.
|
|
| 05/20/2026 | R:INSULATION | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 5/19/2026 9:06:28 AM
5/19/2026 9:06 AM CASCO CONSTRUCTION LLC
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
|
|
| 05/20/2026 | R:RE-ROUGH FRAME | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 5/19/2026 9:05:05 AM
5/19/2026 9:05 AM CASCO CONSTRUCTION LLC
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
5/20/2026 4:09:17 PM
Corrections made
|
|
| 06/03/2026 | R:FIRE RESISTIVE | MARTIN MAGERS | APPROVED | eTRAKiT Inspection Request | 6/2/2026 7:03:11 AM
6/2/2026 7:03 AM CASCO CONSTRUCTION LLC
No Burn Cert and site plan in permit box on green tool box in garage
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
|
|
| 06/03/2026 | R:SHEAR WALL_DRYWALL | MARTIN MAGERS | NOT APPROVED | eTRAKiT Inspection Request | 6/2/2026 7:00:31 AM
6/2/2026 7:00 AM CASCO CONSTRUCTION LLC
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
6/3/2026 11:54:29 AM
Please remove steel screws and replace with corrosive resistive screws in all showers.
|
|
| 06/05/2026 | R:SHEAR WALL_DRYWALL | JOE CARBAUGH | APPROVED | eTRAKiT Inspection Request | 6/4/2026 4:33:40 PM
6/4/2026 4:33 PM CASCO CONSTRUCTION LLC
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: chrisp@cascocc.com
6/5/2026 11:20:59 AM
APPROVED.
|
|
| 11/03/2026 | U: METER SET | GRANT TAYLOR | METER INSP FAIL 1 | | 11/3/2026 1:24:05 PM
A $50.00 re-inspection fee will be charged to the building permit. Once corrections have been made, please email your request for a re-inspection to meterset@crgov.com. Please note that we have up to four business days from the initial request to complete the re-inspection.
Curbstop needs to be 4-6" above grade.
Need TOCR IRR plan and placard in the garage.
Mxu must be 8x8 mount with pex flushed.
Meter yoke has to be left to right.
|
|
| 11/06/2026 | L:SITE VISIT | WILLIAM BROWN | DAILY OBSERVE DONE | landscape and irrigation | 11/6/2026 12:28:43 PM
met w/ Chris Palmer onsite, 719.669.9508
landscaping projected for Spring/Summer 2027, currently rough grad, fire mitigation.
2/10/2026 approved plan is no longer viable, design will remove driveway arc and retaining wall, utilize existing trees, native slope, front site inlet area
|
|
| 11/17/2026 | R:FINAL PLUMBING | COLBY RIGGINS | NOT APPROVED | eTRAKiT Inspection Request | 11/11/2026 7:46:27 AM
11/11/2026 7:46 AM AFAB PLUMBING LLC
Contact Name: AFAB PLUMBING LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196835788
e-Mail: AFABPLUMBING@GMAIL.COM
11/16/2026 1:18:40 PM
11/16/2026 1:18 PM AFAB PLUMBING LLC
Contact Name: AFAB PLUMBING LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196835788
e-Mail: AFABPLUMBING@GMAIL.COM
11/17/2026 2:51:07 PM
1. No hot water front bar area sink
2. Sink next to the fridge at side water line has no water
3. Master toilet inoperable
4. Master shower door and upper glass does not have tampered glass
5. Upstairs bathroom sink has a leak underneath
6. Upstairs laundry room floor drain missing trap guard and cover
7. Rear upstairs bedroom sink inoperable, shower escutcheon ring not sealed, shower side glass piece not tempered
8. Hose bib in the front is not secured
9. Gas lines need to be painted
|
|
| 11/17/2026 | U:HE TOILET | WILLIAM BROWN | NOT APPROVED | VOIDED (WIBR 11/20/2026) | 11/13/2026 4:05:51 PM
11/13/2026 4:05 PM CASCO CONSTRUCTION LLC
Contact Name: CASCO CONSTRUCTION LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196699508
e-Mail: Chrisp@CASCOCC.COM
11/17/2026 7:53:04 AM
Toto 1.28
reference photo in attachments
11/20/2026 6:52:11 AM
permit date excepted. inspection void.
11/20/2026 6:52:21 AM
Inspection voided by WIBR. Most recent remarks follow: eTRAKiT Inspection Request
|
|
| U:HE TOILET REINSPECTION | WILLIAM BROWN | TOILET REINSPECTION | VOIDED (WIBR 11/20/2026) | 11/20/2026 6:52:59 AM
permit date excepted. inspection void.
11/20/2026 6:53:06 AM
Inspection voided by WIBR.
|
|
| 11/20/2026 | R:FINAL PLUMBING | COLBY RIGGINS | APPROVED | eTRAKiT Inspection Request | 11/19/2026 9:03:27 PM
11/19/2026 9:03 PM AFAB PLUMBING LLC
Contact Name: AFAB PLUMBING LLC
Site Address: 1993 AVENIDA DEL SOL
Phone: 7196835788
e-Mail: AFABPLUMBING@GMAIL.COM
11/20/2026 2:37:18 PM
Approved
|
|