Permit No. 24-4582 Permit Type   RESIDENTIAL CUSTOM Site Address   1993 AVENIDA DEL SOL
CASTLE ROCK, CO 80104
Applied   11/21/2024 Applicant   Nick Sallecchia
Approved   02/28/2025 Owner   JAMIN HOUSER & STACIE HOUSER
Issued   03/04/2025 Contractor  
Parent Permit No.   Description   NEW SINGLE FAMILY DETACHED CUSTOM RESIDENCE
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 03/06/2025T:INITIALBRIAN LASCHANZKYAPPROVED3/6/2025 2:49:01 PM This lot has many retaining walls planned and several are over 4ft in height. Retaining walls 4ft or over MUST be ENGINEERED and a Retaining Wall PERMIT obtained from the Town of Castle Rock. Retaining wall height INCLUDES the Height of the footing. For example, if the wall is 3ft high from grade with a 1ft footing pad, the height of the retaining wall would be 4FT NOT 3Ft. Reference the permit number for retaining wall(s) on Plot plan and on Final Grade certificate plan 3/6/2025 2:54:45 PM Repair one section of Silt Fence (SF) that is sagging needs re-attached. The remainder of SF is. No tracking noted at this time. good. Inlet Protection for Area Inlet on-site and Type R inlet on street use of this alternative will be allowed at thios time for now Using alternative rock sock not wire When in need of maintenance, replace with Town of Castle Rock standard detail wire wrapped rock inlet protection for both the AREA INLET and type R inlet.

 04/09/2025T:ROUTINEBRIAN LASCHANZKYTESC LIII4/9/2025 1:12:14 PM Sweep street curb and sidewalk clean out FODS and move them to the front at back of sidewalk as discussed today on-site. Good seeing you. IP changed out looks good. Good work

 05/05/2025T:ROUTINEBRIAN LASCHANZKYTESC LIII5/5/2025 9:49:10 AM 4-9-25 inspection notes: Sweep street curb and sidewalk clean out FODS and move them to the front at back of sidewalk as discussed today on-site. Good seeing you. IP changed out looks good. Good work 5/5/2025 12:44:04 PM Sweep entrance. Wrap SF at corner to prevent sediment transport out this front west corner. Clean sediment from FODS. Replace where damaged.

 06/04/2025T:ROUTINEBRIAN LASCHANZKYTESC LIIIMUDDY CONDITIONS consider temp shut down6/4/2025 11:16:43 AM Repair SF sweep Keep trade vehicles off muddy lot postpone deliveries if possible until the site dries out. If cannot , any tracking MUST be swept/scraped and fully CONTROLLED NO TRACKING SHOULD BE PRESENT ESPECIALLY OVERNIGHT CONSIDER temp shut down to let the site dry out. fighting muddy conditions typically are not worth the potential costly issues, rutting up the site, tracking getting vehicles stuck the clean up is typically costly and can outweigh the lost day or two of construction.

 06/24/2025R:TEMP CONST METERADAM KINDLEAPPROVEDTYLER 719-310-82086/24/2025 1:48:11 PM Approved please release meter

 07/02/2025T:ROUTINEBRIAN LASCHANZKYTESC LIIIKEEP EYE ON SITE AREA INLET7/2/2025 10:13:13 AM SWEEP KJEEP A CLOSE EYE ON THE AREA DRAINAGE INLET ON-SITE DO NOT ALLOW IT TO GET CLOGGED OR BE UNPROTECTED. ROCK SOCKS PRESENT GOOD. REPAIR SECTION OF SF.

 08/04/2025T:ROUTINEBRIAN LASCHANZKYTESC LIIIWatch stockpile slope could breach8/4/2025 12:38:23 PM Stockpile sloe could easily breach the SF at the corner. Install reinforce SF berm up the toe of the slope or backfiull the foundation. This area is suseptable to a brech in a good rainstorm take action to prevent a breachsweep entrance. the rest is being maintained well.

 09/02/2025T:ROUTINEJESSUP SCHIELDTESC LIIIsee notes9/2/2025 3:58:48 PM • Repair minor silt fence damage on north side of lot.

 09/23/2025R:GRND PLUMBINGCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request9/22/2025 1:58:57 PM 9/22/2025 1:58 PM AFAB PLUMBING LLC Contact Name: AFAB PLUMBING LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196835788 e-Mail: AFABPLUMBING@GMAIL.COM 9/23/2025 10:38:42 AM Approved

 09/30/2025R:ELECTRICAL UNDERGRVINCE RAPONEPARTIALRECEPTACLES IN CONCRETE PAD9/29/2025 3:43:11 PM TYLER 7193108208 9/30/2025 12:56:13 PM 3 - Floor outlets game room / exercise room good

 10/07/2025T:ROUTINEJESSUP SCHIELDTESC LIIIsee notes10/7/2025 3:30:04 PM Repair minor silt fence damage on north side of lot. Sweep street at entrance to site.

 11/06/2025T:ROUTINEJESSUP SCHIELDTESC LIIIsee attached

 12/02/2025T:ROUTINEJESSUP SCHIELDTESC LIIIsee notes12/3/2025 11:32:07 AM • Extend VTC into lot. VTC very short. • Repair erosion near inlet. • Refresh inlet protection to the west of the property.

 12/10/2025R:ELECTRICAL UNDERGRVINCE RAPONEPARTIAL12/9/2025 3:37:48 PM ADDISON 3036601341 if cant find pipe tyler safehouse elctric 7193108208 back porch SW side of building PVC for electrical 12/10/2025 2:26:42 PM Fire pit sleeve SW corner of house good

 12/11/2025R:GAS PIPE AIR TESTMARTIN MAGERSPARTIALeTRAKiT Inspection Request12/10/2025 2:38:53 PM 12/10/2025 2:38 PM KOALA WATER HEATERS Partial inspection for underslab gas stub at main level patio fireplace: 55,000 btus Contact Name: KOALA WATER HEATERS Site Address: 1993 AVENIDA DEL SOL Phone: 7199003213 e-Mail: TIM@KOALAWATERHEATERS.COM 12/11/2025 3:34:40 PM Partial on gas line to fireplace on patio.

 12/23/2025R:WALL BRACINGMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request12/22/2025 1:56:51 PM 12/22/2025 1:56 PM CASCO CONSTRUCTION LLC Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7193801140 e-Mail: CHRISP@CASCOCC.COM 12/23/2025 11:00:50 AM 1. Missing all hold downs. 2. Missing all details for portal framing. Nailing, blocking, strapping, 2x2 washes in sill bolts x2 on each side. 3. Missing all nails in #6 area, no staples allowed. 4. Block all seams. 5. Miss 3 in seam staples in random places throughout on #3 areas, check all.

 12/30/2025R:WALL BRACINGMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request12/29/2025 12:58:55 PM 12/29/2025 12:58 PM CASCO CONSTRUCTION LLC Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7193801140 e-Mail: Chrisp@cascocc.com 12/30/2025 3:37:58 PM Corrections made

 01/06/2026T:ROUTINEJASON INGENTHRONTESC LIIIsee notes1/6/2026 5:18:39 PM This inspection found the following deficiencies: maintenance for Type-R inlet protection, installation of inlet protection on Type-C catch basin, Silt fence repairs. There is a file with photos and additional information that was uploaded 1.6.25

 01/07/2026R:WTHR RESIS BARRIERJOE CARBAUGHPARTIALeTRAKiT Inspection Request1/6/2026 1:46:09 PM 1/6/2026 1:46 PM CASCO CONSTRUCTION LLC Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: Chrisp@CASCOCC.COM 1/7/2026 11:06:03 AM TYVEK AREAS OK. CALL LATH INSPECTION FOR NON TYVEK AREAS OR SECOND WEATHER BARRIER INSPECTION WHEN READY FOR STUCCO OR BRICK.

 01/20/2026T:ROUTINEJASON INGENTHRONTESC LIIISee Notes1/20/2026 4:02:05 PM Site visit conducted today, 1-20-26: inlet protection requires additional corrections to be functional, area drain controls are satisfactory for a temporary configuration. No tracking was observed; however additional improvements will be needed as we move out of frozen temperatures. Email with photos sent to contractor. email function not working from iPad app

 02/10/2026T:ROUTINEJASON INGENTHRONCANCEL2/10/2026 3:35:30 PM Site will be inspected tomorrow. The date listed on this item is incorrect therefore, inspection will be canceled.

 02/12/2026T:ROUTINEJASON INGENTHRONTESC LIIISee Notes2/12/2026 1:59:56 PM The type-R inlet in the roadway requires corrective action to create functional sediment protection. No gaps between the bags and no voids underneath the bags which would let untreated stormwater enter the system. Remove old, non-functional rock bags from inlet and ensure new design conform to Castle Rock standards. See attached photos. Please send photos of the repaired inlet protection via email

 02/18/2026R:ROUGH PLUMBINGMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request2/17/2026 3:23:55 PM 2/17/2026 3:23 PM AFAB PLUMBING LLC Contact Name: AFAB PLUMBING LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196835788 e-Mail: AFABPLUMBING@GMAIL.COM 2/18/2026 12:34:44 PM Water and DWV test ok 1. Vents not extended trough roof.. please remove caps, exstend vents trough roof and recall.

 02/23/2026R:ROUGH PLUMBINGCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request2/20/2026 7:55:02 AM 2/20/2026 7:55 AM AFAB PLUMBING LLC Contact Name: AFAB PLUMBING LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196835788 e-Mail: AFABPLUMBING@GMAIL.COM 2/23/2026 12:17:50 PM Approved

 02/23/2026R:PORCH POST REARCOLBY RIGGINSNOT APPROVEDSpecial on interior vaulted ceilings2/18/2026 2:34:35 PM 2/18/2026 2:34 PM CASCO CONSTRUCTION LLC Special on interior vaulted ceilings on main level Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: Chrisp@CASCOCC.COM 2/23/2026 12:17:53 PM 1. No plans onsite to verify details.

 02/26/2026R:GAS PIPE AIR TESTMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request2/25/2026 9:07:00 PM 2/25/2026 9:07 PM KOALA WATER HEATERS Contact Name: KOALA WATER HEATERS Site Address: 1993 AVENIDA DEL SOL Phone: 7199003213 e-Mail: TIM@KOALAWATERHEATERS.COM 2/26/2026 10:33:41 AM No town approved gas iso on site. Please submit as built gas iso and recall when you can have printed approved plans on site.

 02/27/2026R:ELECTRICAL UNDERGRSHAWN VALENZUELAPARTIALTyler 71931082082/27/2026 12:13:34 PM 2 200 amp services coming off meter pedestal 2 200 amp disconnect will be installed at back of house (not installed at the time) Meter pedestal needs to still be upgraded by core 2/27/2026 1:12:32 PM 2 200 amp services coming from meter pedestal

 03/05/2026T:ROUTINEJASON INGENTHRONTESC LIIIsee photos3/5/2026 5:34:31 PM Site visit found several deficiencies with BMPs. Silt fence must be trenched into the ground at several locations. Inlet protection requires modification and repair - close gaps between rock socks. VTC requires new rock and measures to be taken to prevent runoff from leaving the site via the driveway cut

 03/06/2026T:ROUTINEJASON INGENTHRONTESC LIIIVOIDED (JAIN 3/6/2026)3/6/2026 11:08:07 AM Site visit found several deficiencies requiring repair.: Silt fence must be anchored into the ground. Several locations required trenching. Inlet protection has gaps between the rock bags which allows sediment to enter the inlet. Remove sediment from inlet, remove old rock bags from around Inlet, reposition rock bags to ensure no gaps exist, or replace with a continuous rock sock (or rock filled wire mesh). VTC require requires maintenance at additional rock to stabilize entrance Adjust site grade to prevent runoff from leaving the site down the driveway 3/6/2026 11:09:12 AM Inspection voided by JAIN.

 03/11/2026R:PORCH POST REARMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request3/10/2026 1:09:08 PM 3/10/2026 1:09 PM CASCO CONSTRUCTION LLC Special on truss hardware on vaults with osb lids Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: Chrisp@CASCOCC.COM 3/11/2026 9:26:19 AM Posts and lid approved.

 03/16/2026R:GAS PIPE AIR TESTMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request3/13/2026 2:14:06 PM 3/13/2026 2:14 PM KOALA WATER HEATERS Printed Plans Located on top of Water Heater Contact Name: KOALA WATER HEATERS Site Address: 1993 AVENIDA DEL SOL Phone: 7199003213 e-Mail: TIM@KOALAWATERHEATERS.COM 3/16/2026 2:46:33 PM 1. Pipe immediately leaving regulators 4 and 5 need to be upsized to 1" and 1 1/4" respectively. Please clearly which regulator was used and the capacity of 5hat regulator,

 03/19/2026R:GAS PIPE AIR TESTMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request3/18/2026 10:44:38 PM 3/18/2026 10:44 PM KOALA WATER HEATERS Contact Name: KOALA WATER HEATERS Site Address: 1993 AVENIDA DEL SOL Phone: 7199003213 e-Mail: TIM@KOALAWATERHEATERS.COM 3/19/2026 9:04:36 AM Corrections made

R:ROUGH MECHANICALMARTIN MAGERSeTRAKiT Inspection Request3/19/2026 9:00:42 AM 3/19/2026 9:00 AM CASCO CONSTRUCTION LLC Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com

 03/20/2026R:WTHR RESIS BARRIERMARTIN MAGERSAPPROVEDMid Roof Inspection3/19/2026 9:03:52 AM 3/19/2026 9:03 AM CASCO CONSTRUCTION LLC Needing Mid Roof inspected before stocking roof tiles on the roof. Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com 3/20/2026 9:33:03 AM Mid roof approved for tile roof.

 03/23/2026R:ROUGH MECHANICALCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request3/19/2026 1:31:13 PM 3/19/2026 1:31 PM CASCO CONSTRUCTION LLC Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com 3/23/2026 2:26:31 PM Approved

 03/31/2026R:LATH_STONE_BRICKCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request3/30/2026 3:27:51 PM 3/30/2026 3:27 PM CASCO CONSTRUCTION LLC Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com 3/31/2026 12:34:57 PM Approved

 03/31/2026R:WTHR RESIS BARRIERCOLBY RIGGINSAPPROVED3/31/2026 2:12:43 PM Approved

 04/03/2026R:ROUGH ELECTRICALVINCE RAPONENOT APPROVED4/2/2026 4:03:41 PM TYLER 7193108208 4/3/2026 10:55:01 AM Garage - did not inspect - not ready Bedroom ceiling fan no box Pantry small appliance circuits - 4 devices per circuit Stair switch incomplete Basement coach lights need stubbed out in basement Complete j box at basement low volt wall Upstairs wire under framing in bathroom Strap and secure all speaker wire and low volt wire Pull 2 cold water and 2 user bonds. One for each service

 04/03/2026T:ROUTINEJASON INGENTHRONTESC LIII4/6/2026 7:48:25 AM An email was sent to the Chris with Casco - it included photos of the deficiencies - the email function built into Track It is not working. 4/6/2026 8:22:54 AM There are multiple violations on site. They are as follows: insufficient vehicle tracking control, dirt, track out offsite, silt fence damage damaged and in disrepair and nonfunctional Send photos of corrected best management practices within two weeks of receiving this report. Also feel welcome to reach out to me with any questions.

 04/13/2026R:ROUGH ELECTRICALVINCE RAPONEPARTIALTYLER 71931082084/13/2026 10:36:30 AM Rough electrical good - okay to insulate Schedule rough electrical once service is complete

 04/14/2026R:REQ PRE ROUGH DOCBUILDING COUNTERNOT APPROVEDeTRAKiT Inspection Request4/13/2026 1:48:50 PM 4/13/2026 1:48 PM CASCO CONSTRUCTION LLC Pre-Rough Docs and Foundation Compliance Forms uploaded Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com 4/14/2026 8:17:02 AM WATER & SEWER; NO BURN

 04/14/2026R:ROUGH FRAMECOLBY RIGGINSNOT APPROVEDtrusses4/13/2026 1:52:26 PM 4/13/2026 1:52 PM CASCO CONSTRUCTION LLC Requesting Trusses only due to size of the home. Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com 4/14/2026 3:11:50 PM 1. Missing sds screws on 3 ply girder at cg2 trusses into bearing blocks 2. All four ply girder trusses or more require sds screws on both sides or through bolts 3.ls 70 missing at upper level storage at 2x8 joist in the garage 4. At two ply girder left of garage entry door behind the master shower is missing a stud 5. Trusses f1-4 missing lateral bracing at web w3 6. Ls30 missing at h1 h2 trusses at rear slider 7. Please get an engineer judgement on detail s 3 (1) looks like the wrong detail the welding to the hanger in the great next to slider 8. Missing ledger at connection to h1 trusses 9. Ledger lock 2 at 16 onc at nj trusses at study closet 10. Uploaded engineer letter for G3 trusses modification for furnace on second floor Note Study and front and rear porch have been already looked at

 04/15/2026R:ROUGH FRAMECOLBY RIGGINSNOT APPROVEDHeaders, Jacks & Kings for rough frame4/15/2026 6:20:57 AM 4/15/2026 6:20 AM CASCO CONSTRUCTION LLC Headers, Jacks & Kings for rough frame Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com 4/15/2026 2:39:45 PM 1. Three north facing first floor windows in the bedroom are missing king studs 2. Bathroom window next to the three north windows is missing a king stud on each side 3. South rear door next to fireplace is missing another king stud 4. Master bedroom door to exterior missing a king stud next to the fire place 5. Master bathroom missing a king stud on each side of the windows 6. Engineer letter for master bathroom side LVL's that run to the basement. Steel ibeams not inspected

 04/17/2026R:RE_ROUGH FRAMECOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request4/16/2026 12:51:41 PM 4/16/2026 12:51 PM CASCO CONSTRUCTION LLC Re inspect Truss repairs and headers, trimmers and king stud corrections. Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com 4/17/2026 2:33:41 PM Headers, kings, trimmers: 1. Three north facing first floor windows in the bedroom are missing king studs 3. South rear door next to fireplace is missing another king stud, that is fixed but need to extend the cs to all 5 ply's 5. Master bathroom missing a king stud on each side of the windows, that is fixed but need cs to hit all ply's and hold down needs to be tightened down 6. Engineer letter for master bathroom side LVL's that run to the basement. Steel ibeams not inspected Trusses 2. All four ply girder trusses or more require sds screws on both sides or through bolts, missing at 4 lvl girder in the living room 7. Please get an engineer judgement on detail s 3 (1) looks like the wrong detail the welding to the hanger in the great next to slider Fire blocking and point loads have not been inspected, also no ibeams and there welds have been inspected Note Study and front and rear porch have been already looked at Engineer letter uploaded for G3 and G1A trusses

 04/23/2026R:RE-ROUGH FRAMECOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request4/22/2026 12:43:27 PM 4/22/2026 12:43 PM CASCO CONSTRUCTION LLC Re inspect truss, header and inspect fire/draft stop. Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com 4/23/2026 2:22:43 PM 1. Unconditioned space in the master bedroom next to the fire place at the top plate by the entry door needs fire blocking 2. Upper storage room needs foam at white wire at the top plate 3. Stair stringers are not full bearing throughout, consult engineer on bearing 4. Welding for basement not complete 5. Verify 2 2x10 bearing at all stair landings that they bear into the elevator shaft if not add ls 70s 6. Remove temp blocking at bottom plates 7. Hangers need at landing in the basketball court for egress window 8. Front porch not inspected yet, please tear off part of the top to verify connections Note Call if fire resistive inspection and upload no burn Get water and sewer 3rd party leaders uploaded to complete pre rough docs Make sure fire passes fire sprinkler

 05/04/2026R:REQ PRE ROUGH DOCBUILDING COUNTERNOT APPROVEDCB5/1/2026 2:35:04 PM 5/1/2026 2:35 PM CASCO CONSTRUCTION LLC All Pre Rough Docs uploaded Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com

 05/04/2026R:ROUGH ELECTRICALVINCE RAPONEAPPROVEDelectrical service5/4/2026 2:01:48 PM Rough electrical approved Electrical service approved okay to release meter

 05/04/2026R:RE-ROUGH FRAMEMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request5/1/2026 7:45:39 AM 5/1/2026 7:45 AM CASCO CONSTRUCTION LLC Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com 5/4/2026 1:22:36 PM 3. Stair stringers are not full bearing throughout, consult engineer on bearing 7. Hangers need at landing in the basketball court for egress window 5/4/2026 4:39:20 PM 3. Stair stringers are not full bearing throughout, consult engineer on bearing 7. Hangers need at landing in the basketball court for egress window

 05/06/2026R:REQ PRE ROUGH DOCBUILDING COUNTERAPPROVEDCB5/5/2026 3:55:10 PM 5/5/2026 3:55 PM CASCO CONSTRUCTION LLC All documents uploaded Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com

 05/07/2026T:ROUTINEJASON INGENTHRONTESC NONESee attached5/7/2026 12:50:23 PM Inspection was conducted 5/5/26 and inspection report has been sent via email and uploaded to the project file.

 05/18/2026R:RE-ROUGH FRAMEMARTIN MAGERSCANCELeTRAKiT Inspection Request5/17/2026 10:11:48 AM 5/17/2026 10:11 AM CASCO CONSTRUCTION LLC Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com 5/18/2026 8:53:50 AM Canceled per call with Chris.

 05/20/2026R:INSULATIONMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request5/19/2026 9:06:28 AM 5/19/2026 9:06 AM CASCO CONSTRUCTION LLC Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com

 05/20/2026R:RE-ROUGH FRAMEMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request5/19/2026 9:05:05 AM 5/19/2026 9:05 AM CASCO CONSTRUCTION LLC Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com 5/20/2026 4:09:17 PM Corrections made

 06/03/2026R:FIRE RESISTIVEMARTIN MAGERSAPPROVEDeTRAKiT Inspection Request6/2/2026 7:03:11 AM 6/2/2026 7:03 AM CASCO CONSTRUCTION LLC No Burn Cert and site plan in permit box on green tool box in garage Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com

 06/03/2026R:SHEAR WALL_DRYWALLMARTIN MAGERSNOT APPROVEDeTRAKiT Inspection Request6/2/2026 7:00:31 AM 6/2/2026 7:00 AM CASCO CONSTRUCTION LLC Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com 6/3/2026 11:54:29 AM Please remove steel screws and replace with corrosive resistive screws in all showers.

 06/05/2026R:SHEAR WALL_DRYWALLJOE CARBAUGHAPPROVEDeTRAKiT Inspection Request6/4/2026 4:33:40 PM 6/4/2026 4:33 PM CASCO CONSTRUCTION LLC Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: chrisp@cascocc.com 6/5/2026 11:20:59 AM APPROVED.

 11/03/2026U: METER SETGRANT TAYLORMETER INSP FAIL 111/3/2026 1:24:05 PM A $50.00 re-inspection fee will be charged to the building permit. Once corrections have been made, please email your request for a re-inspection to meterset@crgov.com. Please note that we have up to four business days from the initial request to complete the re-inspection. Curbstop needs to be 4-6" above grade. Need TOCR IRR plan and placard in the garage. Mxu must be 8x8 mount with pex flushed. Meter yoke has to be left to right.

 11/06/2026L:SITE VISITWILLIAM BROWNDAILY OBSERVE DONElandscape and irrigation11/6/2026 12:28:43 PM met w/ Chris Palmer onsite, 719.669.9508 landscaping projected for Spring/Summer 2027, currently rough grad, fire mitigation. 2/10/2026 approved plan is no longer viable, design will remove driveway arc and retaining wall, utilize existing trees, native slope, front site inlet area

 11/17/2026R:FINAL PLUMBINGCOLBY RIGGINSNOT APPROVEDeTRAKiT Inspection Request11/11/2026 7:46:27 AM 11/11/2026 7:46 AM AFAB PLUMBING LLC Contact Name: AFAB PLUMBING LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196835788 e-Mail: AFABPLUMBING@GMAIL.COM 11/16/2026 1:18:40 PM 11/16/2026 1:18 PM AFAB PLUMBING LLC Contact Name: AFAB PLUMBING LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196835788 e-Mail: AFABPLUMBING@GMAIL.COM 11/17/2026 2:51:07 PM 1. No hot water front bar area sink 2. Sink next to the fridge at side water line has no water 3. Master toilet inoperable 4. Master shower door and upper glass does not have tampered glass 5. Upstairs bathroom sink has a leak underneath 6. Upstairs laundry room floor drain missing trap guard and cover 7. Rear upstairs bedroom sink inoperable, shower escutcheon ring not sealed, shower side glass piece not tempered 8. Hose bib in the front is not secured 9. Gas lines need to be painted

 11/17/2026U:HE TOILETWILLIAM BROWNNOT APPROVEDVOIDED (WIBR 11/20/2026)11/13/2026 4:05:51 PM 11/13/2026 4:05 PM CASCO CONSTRUCTION LLC Contact Name: CASCO CONSTRUCTION LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196699508 e-Mail: Chrisp@CASCOCC.COM 11/17/2026 7:53:04 AM Toto 1.28 reference photo in attachments 11/20/2026 6:52:11 AM permit date excepted. inspection void. 11/20/2026 6:52:21 AM Inspection voided by WIBR. Most recent remarks follow: eTRAKiT Inspection Request

U:HE TOILET REINSPECTIONWILLIAM BROWNTOILET REINSPECTIONVOIDED (WIBR 11/20/2026)11/20/2026 6:52:59 AM permit date excepted. inspection void. 11/20/2026 6:53:06 AM Inspection voided by WIBR.

 11/20/2026R:FINAL PLUMBINGCOLBY RIGGINSAPPROVEDeTRAKiT Inspection Request11/19/2026 9:03:27 PM 11/19/2026 9:03 PM AFAB PLUMBING LLC Contact Name: AFAB PLUMBING LLC Site Address: 1993 AVENIDA DEL SOL Phone: 7196835788 e-Mail: AFABPLUMBING@GMAIL.COM 11/20/2026 2:37:18 PM Approved